使用含氟溶液和不含氟溶液的双酸蚀刻治疗种植体稳定性的临床对比评估:随机临床试验。

Q2 Dentistry Journal of Indian Society of Periodontology Pub Date : 2024-03-01 Epub Date: 2024-08-31 DOI:10.4103/jisp.jisp_52_23
Fernando Luiz Kaesemodel Hoppe, Márcio de Carvalho Formiga, Gislaine Fernandes Felipe Garcia, Rafael Manfro, Marcelo Carlos Bortoluzzi
{"title":"使用含氟溶液和不含氟溶液的双酸蚀刻治疗种植体稳定性的临床对比评估:随机临床试验。","authors":"Fernando Luiz Kaesemodel Hoppe, Márcio de Carvalho Formiga, Gislaine Fernandes Felipe Garcia, Rafael Manfro, Marcelo Carlos Bortoluzzi","doi":"10.4103/jisp.jisp_52_23","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Osseointegration depends on primary stability, and further, implant surface modifications may improve secondary stability. This randomized clinical trial evaluates whether adding a fluoride solution enhances the implant stability.</p><p><strong>Materials and methods: </strong>Stability of dental implants with two different types of surface treatments was compared utilizing resonance frequency analysis (RFA). Twelve patients were recruited: eight females and four males with an average age of 58.3 years and they received either double acid etched implants (control: Porus Implant, Sistema Conexão) and double acid etched implants containing fluoride on their surfaces (test: Porus Nano Implant, Sistema Conexão). Each patient received one implant from the test category and another implant from the control category, resulting in 24 implants in this study. RFA, utilizing Osstell was used to assess the implant stability, immediately after the placement of implant and 15, 30 and 45 days post-implant placement.</p><p><strong>Results: </strong>At the initial time, there was no difference between the test and control groups regarding the ISQ. However, after 15, 30, and 45 days, ISQ values for the test group were significantly higher than the control group. When using implants without fluoride addition, it was observed that after 15 days, the ISQ values were lower than those found at the initial time, but after 30 days, values matched the initial. Concerning the test group results, the ISQ values from T0 (immediately after implant placement) to T3 (45 days after implant placement) always increased from every period of evaluation.</p><p><strong>Conclusions: </strong>It was concluded that double acid etched implants with surfaces containing fluoride solution increases the implant stability quotient, compared to implants with fluoride-free double acid etched surfaces.</p>","PeriodicalId":15890,"journal":{"name":"Journal of Indian Society of Periodontology","volume":"28 2","pages":"185-191"},"PeriodicalIF":0.0000,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11472973/pdf/","citationCount":"0","resultStr":"{\"title\":\"Comparative clinical evaluation of the stability of implants using double acid etching treatment with and without the addition of fluoride solution: A randomized clinical trial.\",\"authors\":\"Fernando Luiz Kaesemodel Hoppe, Márcio de Carvalho Formiga, Gislaine Fernandes Felipe Garcia, Rafael Manfro, Marcelo Carlos Bortoluzzi\",\"doi\":\"10.4103/jisp.jisp_52_23\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Osseointegration depends on primary stability, and further, implant surface modifications may improve secondary stability. This randomized clinical trial evaluates whether adding a fluoride solution enhances the implant stability.</p><p><strong>Materials and methods: </strong>Stability of dental implants with two different types of surface treatments was compared utilizing resonance frequency analysis (RFA). Twelve patients were recruited: eight females and four males with an average age of 58.3 years and they received either double acid etched implants (control: Porus Implant, Sistema Conexão) and double acid etched implants containing fluoride on their surfaces (test: Porus Nano Implant, Sistema Conexão). Each patient received one implant from the test category and another implant from the control category, resulting in 24 implants in this study. RFA, utilizing Osstell was used to assess the implant stability, immediately after the placement of implant and 15, 30 and 45 days post-implant placement.</p><p><strong>Results: </strong>At the initial time, there was no difference between the test and control groups regarding the ISQ. However, after 15, 30, and 45 days, ISQ values for the test group were significantly higher than the control group. When using implants without fluoride addition, it was observed that after 15 days, the ISQ values were lower than those found at the initial time, but after 30 days, values matched the initial. Concerning the test group results, the ISQ values from T0 (immediately after implant placement) to T3 (45 days after implant placement) always increased from every period of evaluation.</p><p><strong>Conclusions: </strong>It was concluded that double acid etched implants with surfaces containing fluoride solution increases the implant stability quotient, compared to implants with fluoride-free double acid etched surfaces.</p>\",\"PeriodicalId\":15890,\"journal\":{\"name\":\"Journal of Indian Society of Periodontology\",\"volume\":\"28 2\",\"pages\":\"185-191\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11472973/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Indian Society of Periodontology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4103/jisp.jisp_52_23\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/8/31 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"Dentistry\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Indian Society of Periodontology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/jisp.jisp_52_23","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/31 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0

摘要

背景:骨结合依赖于主要稳定性,而种植体表面的改良可进一步提高次要稳定性。这项随机临床试验评估了添加氟化物溶液是否能提高种植体的稳定性:采用共振频率分析法(RFA)比较了经过两种不同表面处理的种植体的稳定性。共招募了 12 名患者:8 名女性和 4 名男性,平均年龄为 58.3 岁。他们分别接受了双酸蚀种植体(对照组:Porus 种植体,Sistema Conexão)和表面含氟的双酸蚀种植体(测试组:Porus 纳米种植体,Sistema Conexão)。每名患者接受一个测试类种植体和另一个对照类种植体,因此本研究共使用了 24 个种植体。在种植体植入后的第一时间以及植入后的 15 天、30 天和 45 天,使用 Osstell RFA 评估种植体的稳定性:结果:最初,试验组和对照组的 ISQ 没有差异。但在 15、30 和 45 天后,试验组的 ISQ 值明显高于对照组。在使用未添加氟化物的种植体时,观察到 15 天后的 ISQ 值低于初始值,但 30 天后的 ISQ 值与初始值一致。关于测试组的结果,从 T0(种植体植入后立即)到 T3(种植体植入后 45 天),每个评估阶段的 ISQ 值都在增加:结论:与无氟双酸蚀表面的种植体相比,含氟双酸蚀表面的种植体能提高种植体的稳定性商数。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Comparative clinical evaluation of the stability of implants using double acid etching treatment with and without the addition of fluoride solution: A randomized clinical trial.

Background: Osseointegration depends on primary stability, and further, implant surface modifications may improve secondary stability. This randomized clinical trial evaluates whether adding a fluoride solution enhances the implant stability.

Materials and methods: Stability of dental implants with two different types of surface treatments was compared utilizing resonance frequency analysis (RFA). Twelve patients were recruited: eight females and four males with an average age of 58.3 years and they received either double acid etched implants (control: Porus Implant, Sistema Conexão) and double acid etched implants containing fluoride on their surfaces (test: Porus Nano Implant, Sistema Conexão). Each patient received one implant from the test category and another implant from the control category, resulting in 24 implants in this study. RFA, utilizing Osstell was used to assess the implant stability, immediately after the placement of implant and 15, 30 and 45 days post-implant placement.

Results: At the initial time, there was no difference between the test and control groups regarding the ISQ. However, after 15, 30, and 45 days, ISQ values for the test group were significantly higher than the control group. When using implants without fluoride addition, it was observed that after 15 days, the ISQ values were lower than those found at the initial time, but after 30 days, values matched the initial. Concerning the test group results, the ISQ values from T0 (immediately after implant placement) to T3 (45 days after implant placement) always increased from every period of evaluation.

Conclusions: It was concluded that double acid etched implants with surfaces containing fluoride solution increases the implant stability quotient, compared to implants with fluoride-free double acid etched surfaces.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.70
自引率
0.00%
发文量
87
审稿时长
44 weeks
期刊介绍: The Journal of Indian Society of Periodontology publishes original scientific articles to support practice , education and research in the dental specialty of periodontology and oral implantology. Journal of Indian Society of Periodontology (JISP), is the official publication of the Society and is managed and brought out by the Editor of the society. The journal is published Bimonthly with special issues being brought out for specific occasions. The ISP had a bulletin as its publication for a large number of years and was enhanced as a Journal a few years ago
期刊最新文献
Applications of a minimally invasive roll flap technique in peri-implant soft-tissue augmentation - A case series. Impact of periodontal phenotype on the outcome of subgingival instrumentation in Stage II and III, Grade A and B periodontitis. Indian Society of Periodontology Scientific Events. Is the oral hygiene complete without the tongue cleaning? Longterm success of implants: Supportive peri-implant care is the "MANTRA"??
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1