利用锥束计算机断层扫描研究影响临时锚固装置失效的因素。

IF 1.9 4区 医学 Q2 DENTISTRY, ORAL SURGERY & MEDICINE Journal of oral science Pub Date : 2024-01-01 DOI:10.2334/josnusd.24-0180
Amane Yamaguchi, So Koizumi, Ryosuke Ikenaka, Tetsutaro Yamaguchi
{"title":"利用锥束计算机断层扫描研究影响临时锚固装置失效的因素。","authors":"Amane Yamaguchi, So Koizumi, Ryosuke Ikenaka, Tetsutaro Yamaguchi","doi":"10.2334/josnusd.24-0180","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To assess the reasons behind the failure of temporary anchorage devices (TADs) installed in the buccal alveolar zone between the maxillary second premolars and the first molars.</p><p><strong>Methods: </strong>Sixty patients (11 male, 49 female, mean age 21 years) were included. Logistic regression analysis was performed to determine the influence of the following factors on the presence or absence of TAD failure: sex, age, sagittal and vertical skeletal patterns, root contact, bone density, bone contact length, and presence of maxillary sinus perforation. Fisher's exact test was performed to evaluate differences in failure rate between tooth types for teeth in contact with TADs (second premolar or first molar). Measurements were obtained using lateral cephalograms at the initial visit and data obtained by cone-beam computed tomography (CBCT) before and after TAD implantation.</p><p><strong>Results: </strong>Logistic regression analysis showed that only root contact was associated with TAD failure; there was no association between the type of tooth in contact with the TAD and failure.</p><p><strong>Conclusion: </strong>Root contact with a TAD significantly influenced TAD failure. Therefore, preliminary examination using three-dimensional (3D) evaluation with CBCT is essential to ensure that the TAD is not placed near the root of the tooth.</p>","PeriodicalId":16646,"journal":{"name":"Journal of oral science","volume":null,"pages":null},"PeriodicalIF":1.9000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Use of cone-beam computed tomography for investigation of factors affecting the failure of temporary anchorage devices.\",\"authors\":\"Amane Yamaguchi, So Koizumi, Ryosuke Ikenaka, Tetsutaro Yamaguchi\",\"doi\":\"10.2334/josnusd.24-0180\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To assess the reasons behind the failure of temporary anchorage devices (TADs) installed in the buccal alveolar zone between the maxillary second premolars and the first molars.</p><p><strong>Methods: </strong>Sixty patients (11 male, 49 female, mean age 21 years) were included. Logistic regression analysis was performed to determine the influence of the following factors on the presence or absence of TAD failure: sex, age, sagittal and vertical skeletal patterns, root contact, bone density, bone contact length, and presence of maxillary sinus perforation. Fisher's exact test was performed to evaluate differences in failure rate between tooth types for teeth in contact with TADs (second premolar or first molar). Measurements were obtained using lateral cephalograms at the initial visit and data obtained by cone-beam computed tomography (CBCT) before and after TAD implantation.</p><p><strong>Results: </strong>Logistic regression analysis showed that only root contact was associated with TAD failure; there was no association between the type of tooth in contact with the TAD and failure.</p><p><strong>Conclusion: </strong>Root contact with a TAD significantly influenced TAD failure. Therefore, preliminary examination using three-dimensional (3D) evaluation with CBCT is essential to ensure that the TAD is not placed near the root of the tooth.</p>\",\"PeriodicalId\":16646,\"journal\":{\"name\":\"Journal of oral science\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.9000,\"publicationDate\":\"2024-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of oral science\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.2334/josnusd.24-0180\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of oral science","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.2334/josnusd.24-0180","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

目的:评估安装在上颌第二前磨牙和第一磨牙之间的颊齿槽区的临时固定装置(TAD)失败的原因:纳入 60 名患者(男性 11 人,女性 49 人,平均年龄 21 岁)。进行了逻辑回归分析,以确定以下因素对是否存在 TAD 失败的影响:性别、年龄、矢状和垂直骨骼形态、牙根接触、骨密度、骨接触长度以及是否存在上颌窦穿孔。费雪精确检验用于评估与 TAD(第二前磨牙或第一磨牙)接触的牙齿类型之间失败率的差异。在初次就诊时使用头颅侧位片进行测量,并在 TAD 植入前后使用锥形束计算机断层扫描(CBCT)获得数据:逻辑回归分析表明,只有牙根接触与TAD失败有关;与TAD接触的牙齿类型与失败没有关系:结论:牙根与 TAD 的接触明显影响 TAD 的失败。因此,使用 CBCT 进行三维(3D)评估的初步检查对于确保 TAD 不放置在牙根附近至关重要。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Use of cone-beam computed tomography for investigation of factors affecting the failure of temporary anchorage devices.

Purpose: To assess the reasons behind the failure of temporary anchorage devices (TADs) installed in the buccal alveolar zone between the maxillary second premolars and the first molars.

Methods: Sixty patients (11 male, 49 female, mean age 21 years) were included. Logistic regression analysis was performed to determine the influence of the following factors on the presence or absence of TAD failure: sex, age, sagittal and vertical skeletal patterns, root contact, bone density, bone contact length, and presence of maxillary sinus perforation. Fisher's exact test was performed to evaluate differences in failure rate between tooth types for teeth in contact with TADs (second premolar or first molar). Measurements were obtained using lateral cephalograms at the initial visit and data obtained by cone-beam computed tomography (CBCT) before and after TAD implantation.

Results: Logistic regression analysis showed that only root contact was associated with TAD failure; there was no association between the type of tooth in contact with the TAD and failure.

Conclusion: Root contact with a TAD significantly influenced TAD failure. Therefore, preliminary examination using three-dimensional (3D) evaluation with CBCT is essential to ensure that the TAD is not placed near the root of the tooth.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of oral science
Journal of oral science DENTISTRY, ORAL SURGERY & MEDICINE-MATERIALS SCIENCE, BIOMATERIALS
CiteScore
3.80
自引率
0.00%
发文量
58
期刊介绍: Information not localized
期刊最新文献
A novel air-polishing powder from natural eggshell. Assessment of cytotoxicity, odontoblast-like differentiation, shear bond strength, and microhardness of four orthodontic adhesive composites. Comparison of four different file systems in terms of transportation in S-shaped canals and apically extruded debris. CAD-CAM for removable partial denture fabrication after marginal mandibulectomy based on a well-adjusted pre-existing denture. A micro-computed tomographic evaluation of maxillary first molar accessory root canal morphology in a Black South African subpopulation.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1