在 VitroJet 中进行冰厚度控制和测量,以实现高效的单颗粒结构测定。

IF 3 3区 生物学 Q3 BIOCHEMISTRY & MOLECULAR BIOLOGY Journal of structural biology Pub Date : 2024-10-20 DOI:10.1016/j.jsb.2024.108139
Rene J.M. Henderikx , Maaike J.G. Schotman , Saba Shahzad , Simon A. Fromm , Daniel Mann , Julian Hennies , Thomas V. Heidler , Dariush Ashtiani , Wim J.H. Hagen , Roger J.M. Jeurissen , Simone Mattei , Peter J. Peters , Carsten Sachse , Bart W.A.M.M. Beulen
{"title":"在 VitroJet 中进行冰厚度控制和测量,以实现高效的单颗粒结构测定。","authors":"Rene J.M. Henderikx ,&nbsp;Maaike J.G. Schotman ,&nbsp;Saba Shahzad ,&nbsp;Simon A. Fromm ,&nbsp;Daniel Mann ,&nbsp;Julian Hennies ,&nbsp;Thomas V. Heidler ,&nbsp;Dariush Ashtiani ,&nbsp;Wim J.H. Hagen ,&nbsp;Roger J.M. Jeurissen ,&nbsp;Simone Mattei ,&nbsp;Peter J. Peters ,&nbsp;Carsten Sachse ,&nbsp;Bart W.A.M.M. Beulen","doi":"10.1016/j.jsb.2024.108139","DOIUrl":null,"url":null,"abstract":"<div><div>Embedding biomolecules in vitreous ice of optimal thickness is critical for structure determination by cryo-electron microscopy. Ice thickness assessment and selection of suitable holes for data collection are currently part of time-consuming preparatory routines performed on expensive electron microscopes. To address this challenge, a routine has been developed to measure ice thickness during sample preparation using an optical camera integrated in the VitroJet. This method allows to estimate the ice thickness with an error below ±20 nm for ice layers in the range of 0–70 nm. Additionally, we characterized the influence of pin printing parameters and found that the median ice thickness can be reproduced with a standard deviation below ±11 nm for thicknesses up to 75 nm. Therefore, the ice thickness of buffer-suspended holes on an EM grid can be tuned and measured within the working range relevant for single particle cryo-EM. Single particle structures of apoferritin were determined at two distinct thicknesses of 30 nm and 70 nm. These reconstructions demonstrate the importance of ice thickness for time-efficient cryo-EM structure determination.</div></div>","PeriodicalId":17074,"journal":{"name":"Journal of structural biology","volume":null,"pages":null},"PeriodicalIF":3.0000,"publicationDate":"2024-10-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Ice thickness control and measurement in the VitroJet for time-efficient single particle structure determination\",\"authors\":\"Rene J.M. Henderikx ,&nbsp;Maaike J.G. Schotman ,&nbsp;Saba Shahzad ,&nbsp;Simon A. Fromm ,&nbsp;Daniel Mann ,&nbsp;Julian Hennies ,&nbsp;Thomas V. Heidler ,&nbsp;Dariush Ashtiani ,&nbsp;Wim J.H. Hagen ,&nbsp;Roger J.M. Jeurissen ,&nbsp;Simone Mattei ,&nbsp;Peter J. Peters ,&nbsp;Carsten Sachse ,&nbsp;Bart W.A.M.M. Beulen\",\"doi\":\"10.1016/j.jsb.2024.108139\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>Embedding biomolecules in vitreous ice of optimal thickness is critical for structure determination by cryo-electron microscopy. Ice thickness assessment and selection of suitable holes for data collection are currently part of time-consuming preparatory routines performed on expensive electron microscopes. To address this challenge, a routine has been developed to measure ice thickness during sample preparation using an optical camera integrated in the VitroJet. This method allows to estimate the ice thickness with an error below ±20 nm for ice layers in the range of 0–70 nm. Additionally, we characterized the influence of pin printing parameters and found that the median ice thickness can be reproduced with a standard deviation below ±11 nm for thicknesses up to 75 nm. Therefore, the ice thickness of buffer-suspended holes on an EM grid can be tuned and measured within the working range relevant for single particle cryo-EM. Single particle structures of apoferritin were determined at two distinct thicknesses of 30 nm and 70 nm. These reconstructions demonstrate the importance of ice thickness for time-efficient cryo-EM structure determination.</div></div>\",\"PeriodicalId\":17074,\"journal\":{\"name\":\"Journal of structural biology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":3.0000,\"publicationDate\":\"2024-10-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of structural biology\",\"FirstCategoryId\":\"99\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1047847724000790\",\"RegionNum\":3,\"RegionCategory\":\"生物学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"BIOCHEMISTRY & MOLECULAR BIOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of structural biology","FirstCategoryId":"99","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1047847724000790","RegionNum":3,"RegionCategory":"生物学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"BIOCHEMISTRY & MOLECULAR BIOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

将生物大分子嵌入最佳厚度的玻璃体冰中对于利用低温电子显微镜进行结构测定至关重要。目前,在昂贵的电子显微镜上进行冰层厚度评估和选择合适的数据采集孔是耗时的准备工作的一部分。为了应对这一挑战,我们开发了一种常规方法,利用集成在 VitroJet 中的光学相机在样品制备过程中测量冰厚度。这种方法可以估算出 0 - 70 nm 范围内冰层的厚度,误差低于 ±20 nm。此外,我们还分析了针式打印参数的影响,发现中值冰层厚度可以再现,标准偏差低于±11 nm,厚度可达 75 nm。因此,可以在单颗粒冷冻电镜的相关工作范围内调整和测量电磁网格上缓冲悬浮孔的冰厚度。在 30 nm 和 70 nm 两种不同厚度下测定了阿泊铁蛋白的单颗粒结构。这些重建结果表明了冰厚度对高效冷冻电镜结构测定的重要性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Ice thickness control and measurement in the VitroJet for time-efficient single particle structure determination
Embedding biomolecules in vitreous ice of optimal thickness is critical for structure determination by cryo-electron microscopy. Ice thickness assessment and selection of suitable holes for data collection are currently part of time-consuming preparatory routines performed on expensive electron microscopes. To address this challenge, a routine has been developed to measure ice thickness during sample preparation using an optical camera integrated in the VitroJet. This method allows to estimate the ice thickness with an error below ±20 nm for ice layers in the range of 0–70 nm. Additionally, we characterized the influence of pin printing parameters and found that the median ice thickness can be reproduced with a standard deviation below ±11 nm for thicknesses up to 75 nm. Therefore, the ice thickness of buffer-suspended holes on an EM grid can be tuned and measured within the working range relevant for single particle cryo-EM. Single particle structures of apoferritin were determined at two distinct thicknesses of 30 nm and 70 nm. These reconstructions demonstrate the importance of ice thickness for time-efficient cryo-EM structure determination.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of structural biology
Journal of structural biology 生物-生化与分子生物学
CiteScore
6.30
自引率
3.30%
发文量
88
审稿时长
65 days
期刊介绍: Journal of Structural Biology (JSB) has an open access mirror journal, the Journal of Structural Biology: X (JSBX), sharing the same aims and scope, editorial team, submission system and rigorous peer review. Since both journals share the same editorial system, you may submit your manuscript via either journal homepage. You will be prompted during submission (and revision) to choose in which to publish your article. The editors and reviewers are not aware of the choice you made until the article has been published online. JSB and JSBX publish papers dealing with the structural analysis of living material at every level of organization by all methods that lead to an understanding of biological function in terms of molecular and supermolecular structure. Techniques covered include: • Light microscopy including confocal microscopy • All types of electron microscopy • X-ray diffraction • Nuclear magnetic resonance • Scanning force microscopy, scanning probe microscopy, and tunneling microscopy • Digital image processing • Computational insights into structure
期刊最新文献
Cryo-EM phase-plate images reveal unexpected levels of apparent specimen damage. Structural basis for the effects of Ser387 phosphorylation of MgcRacGAP on its GTPase-activating activities for CDC42 and RHOA. Computational study of the HLTF ATPase remodeling domain suggests its activity on dsDNA and implications in damage tolerance. Vesicle Picker: A tool for efficient identification of membrane protein complexes in vesicles Editorial
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1