{"title":"可穿戴在线步态冻结检测和提示系统。","authors":"Jan Slemenšek, Jelka Geršak, Božidar Bratina, Vesna Marija van Midden, Zvezdan Pirtošek, Riko Šafarič","doi":"10.3390/bioengineering11101048","DOIUrl":null,"url":null,"abstract":"<p><p>This paper presents a real-time wearable system designed to assist Parkinson's disease patients experiencing freezing of gait episodes. The system utilizes advanced machine learning models, including convolutional and recurrent neural networks, enhanced with past sample data preprocessing to achieve high accuracy, efficiency, and robustness. By continuously monitoring gait patterns, the system provides timely interventions, improving mobility and reducing the impact of freezing episodes. This paper explores the implementation of a CNN+RNN+PS machine learning model on a microcontroller-based device. The device operates at a real-time processing rate of 40 Hz and is deployed in practical settings to provide 'on demand' vibratory stimulation to patients. This paper examines the system's ability to operate with minimal latency, achieving an average detection delay of just 261 milliseconds and a freezing of gait detection accuracy of 95.1%. While patients received on-demand stimulation, the system's effectiveness was assessed by decreasing the average duration of freezing of gait episodes by 45%. These preliminarily results underscore the potential of personalized, real-time feedback systems in enhancing the quality of life and rehabilitation outcomes for patients with movement disorders.</p>","PeriodicalId":8874,"journal":{"name":"Bioengineering","volume":"11 10","pages":""},"PeriodicalIF":3.8000,"publicationDate":"2024-10-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11505507/pdf/","citationCount":"0","resultStr":"{\"title\":\"Wearable Online Freezing of Gait Detection and Cueing System.\",\"authors\":\"Jan Slemenšek, Jelka Geršak, Božidar Bratina, Vesna Marija van Midden, Zvezdan Pirtošek, Riko Šafarič\",\"doi\":\"10.3390/bioengineering11101048\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>This paper presents a real-time wearable system designed to assist Parkinson's disease patients experiencing freezing of gait episodes. The system utilizes advanced machine learning models, including convolutional and recurrent neural networks, enhanced with past sample data preprocessing to achieve high accuracy, efficiency, and robustness. By continuously monitoring gait patterns, the system provides timely interventions, improving mobility and reducing the impact of freezing episodes. This paper explores the implementation of a CNN+RNN+PS machine learning model on a microcontroller-based device. The device operates at a real-time processing rate of 40 Hz and is deployed in practical settings to provide 'on demand' vibratory stimulation to patients. This paper examines the system's ability to operate with minimal latency, achieving an average detection delay of just 261 milliseconds and a freezing of gait detection accuracy of 95.1%. While patients received on-demand stimulation, the system's effectiveness was assessed by decreasing the average duration of freezing of gait episodes by 45%. These preliminarily results underscore the potential of personalized, real-time feedback systems in enhancing the quality of life and rehabilitation outcomes for patients with movement disorders.</p>\",\"PeriodicalId\":8874,\"journal\":{\"name\":\"Bioengineering\",\"volume\":\"11 10\",\"pages\":\"\"},\"PeriodicalIF\":3.8000,\"publicationDate\":\"2024-10-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11505507/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Bioengineering\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.3390/bioengineering11101048\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bioengineering","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.3390/bioengineering11101048","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
Wearable Online Freezing of Gait Detection and Cueing System.
This paper presents a real-time wearable system designed to assist Parkinson's disease patients experiencing freezing of gait episodes. The system utilizes advanced machine learning models, including convolutional and recurrent neural networks, enhanced with past sample data preprocessing to achieve high accuracy, efficiency, and robustness. By continuously monitoring gait patterns, the system provides timely interventions, improving mobility and reducing the impact of freezing episodes. This paper explores the implementation of a CNN+RNN+PS machine learning model on a microcontroller-based device. The device operates at a real-time processing rate of 40 Hz and is deployed in practical settings to provide 'on demand' vibratory stimulation to patients. This paper examines the system's ability to operate with minimal latency, achieving an average detection delay of just 261 milliseconds and a freezing of gait detection accuracy of 95.1%. While patients received on-demand stimulation, the system's effectiveness was assessed by decreasing the average duration of freezing of gait episodes by 45%. These preliminarily results underscore the potential of personalized, real-time feedback systems in enhancing the quality of life and rehabilitation outcomes for patients with movement disorders.
期刊介绍:
Aims
Bioengineering (ISSN 2306-5354) provides an advanced forum for the science and technology of bioengineering. It publishes original research papers, comprehensive reviews, communications and case reports. Our aim is to encourage scientists to publish their experimental and theoretical results in as much detail as possible. All aspects of bioengineering are welcomed from theoretical concepts to education and applications. There is no restriction on the length of the papers. The full experimental details must be provided so that the results can be reproduced. There are, in addition, four key features of this Journal:
● We are introducing a new concept in scientific and technical publications “The Translational Case Report in Bioengineering”. It is a descriptive explanatory analysis of a transformative or translational event. Understanding that the goal of bioengineering scholarship is to advance towards a transformative or clinical solution to an identified transformative/clinical need, the translational case report is used to explore causation in order to find underlying principles that may guide other similar transformative/translational undertakings.
● Manuscripts regarding research proposals and research ideas will be particularly welcomed.
● Electronic files and software regarding the full details of the calculation and experimental procedure, if unable to be published in a normal way, can be deposited as supplementary material.
● We also accept manuscripts communicating to a broader audience with regard to research projects financed with public funds.
Scope
● Bionics and biological cybernetics: implantology; bio–abio interfaces
● Bioelectronics: wearable electronics; implantable electronics; “more than Moore” electronics; bioelectronics devices
● Bioprocess and biosystems engineering and applications: bioprocess design; biocatalysis; bioseparation and bioreactors; bioinformatics; bioenergy; etc.
● Biomolecular, cellular and tissue engineering and applications: tissue engineering; chromosome engineering; embryo engineering; cellular, molecular and synthetic biology; metabolic engineering; bio-nanotechnology; micro/nano technologies; genetic engineering; transgenic technology
● Biomedical engineering and applications: biomechatronics; biomedical electronics; biomechanics; biomaterials; biomimetics; biomedical diagnostics; biomedical therapy; biomedical devices; sensors and circuits; biomedical imaging and medical information systems; implants and regenerative medicine; neurotechnology; clinical engineering; rehabilitation engineering
● Biochemical engineering and applications: metabolic pathway engineering; modeling and simulation
● Translational bioengineering