评估电子病历中困难气道警报的效果:一项质量改进研究。

IF 4.6 Q2 MATERIALS SCIENCE, BIOMATERIALS ACS Applied Bio Materials Pub Date : 2024-10-23 DOI:10.1186/s12871-024-02747-8
Wen-Shen Lee, Luke R Fletcher, Shervin Tosif, Timothy Makar, Jon M Graham
{"title":"评估电子病历中困难气道警报的效果:一项质量改进研究。","authors":"Wen-Shen Lee, Luke R Fletcher, Shervin Tosif, Timothy Makar, Jon M Graham","doi":"10.1186/s12871-024-02747-8","DOIUrl":null,"url":null,"abstract":"<p><strong>Study design: </strong>Retrospective analysis of difficult airway alerts in a major tertiary centre.</p><p><strong>Objective: </strong>To investigate the completeness, utility and efficacy of difficult airway alerts and their impact on future airway management episodes.</p><p><strong>Design, data sources and methods: </strong>Patients who had a \"difficult airway\" entry on electronic medical records (EMR) from 2011 to 2021 were included. Each alert was analyzed by a team of anesthetists with expertise in difficult airway management for its quality, appropriateness, and impact on future airway management episodes. Alert quality was defined as to whether the content of the alert contained pertinent information for emergent airway management. Alert appropriateness was defined as to whether the experts would be unhappy to perform a rapid sequence induction and intubation, if required, following review of all available documentation.</p><p><strong>Results: </strong>141 patients were included for this study, with a mean age of 58.6 +/- 15.3 years. Ninety-three (66%) alerts were created by medical staff, of which 52 were recorded by consultant anesthetists. 117 alerts (83%) were deemed to be appropriate by the airway expert team, but only 40 alerts (28%) were found to have sufficient quality to be helpful in emergent airway management. Sixty-five patients (47%) had at least one subsequent airway management episode, of which 35 patients (56%) underwent a change of management following alert creation. We proceeded to modify 103 alerts (73%) to improve their quality to aid future encounters.</p><p><strong>Conclusion: </strong>Difficult Airway encounters are an uncommon event in anesthesia, but clear, comprehensive and effectively communicated documentation is required to minimize the risk in future encounters. In our institution, while most difficult airway alerts were appropriate, we found significant heterogeneity in the quality of this documentation, which limits the clinical utility of the alert system. We have taken measures to improve local processes of difficult airway documentation and considered the implications of our project for the broader airway management community.</p><p><strong>Trial registration: </strong>Not applicable.</p>","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":null,"pages":null},"PeriodicalIF":4.6000,"publicationDate":"2024-10-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11515682/pdf/","citationCount":"0","resultStr":"{\"title\":\"Assessing the efficacy of difficult airway alerts in electronic medical records: a quality improvement study.\",\"authors\":\"Wen-Shen Lee, Luke R Fletcher, Shervin Tosif, Timothy Makar, Jon M Graham\",\"doi\":\"10.1186/s12871-024-02747-8\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Study design: </strong>Retrospective analysis of difficult airway alerts in a major tertiary centre.</p><p><strong>Objective: </strong>To investigate the completeness, utility and efficacy of difficult airway alerts and their impact on future airway management episodes.</p><p><strong>Design, data sources and methods: </strong>Patients who had a \\\"difficult airway\\\" entry on electronic medical records (EMR) from 2011 to 2021 were included. Each alert was analyzed by a team of anesthetists with expertise in difficult airway management for its quality, appropriateness, and impact on future airway management episodes. Alert quality was defined as to whether the content of the alert contained pertinent information for emergent airway management. Alert appropriateness was defined as to whether the experts would be unhappy to perform a rapid sequence induction and intubation, if required, following review of all available documentation.</p><p><strong>Results: </strong>141 patients were included for this study, with a mean age of 58.6 +/- 15.3 years. Ninety-three (66%) alerts were created by medical staff, of which 52 were recorded by consultant anesthetists. 117 alerts (83%) were deemed to be appropriate by the airway expert team, but only 40 alerts (28%) were found to have sufficient quality to be helpful in emergent airway management. Sixty-five patients (47%) had at least one subsequent airway management episode, of which 35 patients (56%) underwent a change of management following alert creation. We proceeded to modify 103 alerts (73%) to improve their quality to aid future encounters.</p><p><strong>Conclusion: </strong>Difficult Airway encounters are an uncommon event in anesthesia, but clear, comprehensive and effectively communicated documentation is required to minimize the risk in future encounters. In our institution, while most difficult airway alerts were appropriate, we found significant heterogeneity in the quality of this documentation, which limits the clinical utility of the alert system. We have taken measures to improve local processes of difficult airway documentation and considered the implications of our project for the broader airway management community.</p><p><strong>Trial registration: </strong>Not applicable.</p>\",\"PeriodicalId\":2,\"journal\":{\"name\":\"ACS Applied Bio Materials\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":4.6000,\"publicationDate\":\"2024-10-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11515682/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACS Applied Bio Materials\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1186/s12871-024-02747-8\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"MATERIALS SCIENCE, BIOMATERIALS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s12871-024-02747-8","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
引用次数: 0

摘要

研究设计对一家大型三级医疗中心的困难气道警报进行回顾性分析:调查困难气道警报的完整性、实用性和有效性及其对未来气道管理事件的影响:纳入2011年至2021年期间在电子病历(EMR)中有 "困难气道 "记录的患者。由具有困难气道管理专业知识的麻醉师组成的团队对每个警报的质量、适当性以及对未来气道管理事件的影响进行分析。警报质量是指警报内容是否包含紧急气道管理的相关信息。警报的适当性是指专家在审阅所有可用文件后,在需要时是否不乐于执行快速顺序诱导和插管:本研究共纳入 141 名患者,平均年龄为 58.6 +/- 15.3 岁。93个警报(66%)由医务人员创建,其中52个由麻醉顾问记录。气道专家小组认为 117 个警报(83%)是适当的,但只有 40 个警报(28%)的质量足以帮助进行紧急气道管理。65 名患者(47%)至少有一次后续气道管理经历,其中 35 名患者(56%)在警报创建后改变了管理方式。我们对 103 个警报(73%)进行了修改,以提高其质量,为今后的处理提供帮助:结论:在麻醉中遇到困难气道并不常见,但需要清晰、全面和有效的沟通文件,以最大限度地降低未来遇到困难气道的风险。在我院,虽然大多数困难气道警报都是适当的,但我们发现这些文件的质量存在很大差异,这限制了警报系统的临床实用性。我们已采取措施改善当地的困难气道记录流程,并考虑了我们的项目对更广泛的气道管理社区的影响:不适用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Assessing the efficacy of difficult airway alerts in electronic medical records: a quality improvement study.

Study design: Retrospective analysis of difficult airway alerts in a major tertiary centre.

Objective: To investigate the completeness, utility and efficacy of difficult airway alerts and their impact on future airway management episodes.

Design, data sources and methods: Patients who had a "difficult airway" entry on electronic medical records (EMR) from 2011 to 2021 were included. Each alert was analyzed by a team of anesthetists with expertise in difficult airway management for its quality, appropriateness, and impact on future airway management episodes. Alert quality was defined as to whether the content of the alert contained pertinent information for emergent airway management. Alert appropriateness was defined as to whether the experts would be unhappy to perform a rapid sequence induction and intubation, if required, following review of all available documentation.

Results: 141 patients were included for this study, with a mean age of 58.6 +/- 15.3 years. Ninety-three (66%) alerts were created by medical staff, of which 52 were recorded by consultant anesthetists. 117 alerts (83%) were deemed to be appropriate by the airway expert team, but only 40 alerts (28%) were found to have sufficient quality to be helpful in emergent airway management. Sixty-five patients (47%) had at least one subsequent airway management episode, of which 35 patients (56%) underwent a change of management following alert creation. We proceeded to modify 103 alerts (73%) to improve their quality to aid future encounters.

Conclusion: Difficult Airway encounters are an uncommon event in anesthesia, but clear, comprehensive and effectively communicated documentation is required to minimize the risk in future encounters. In our institution, while most difficult airway alerts were appropriate, we found significant heterogeneity in the quality of this documentation, which limits the clinical utility of the alert system. We have taken measures to improve local processes of difficult airway documentation and considered the implications of our project for the broader airway management community.

Trial registration: Not applicable.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
ACS Applied Bio Materials
ACS Applied Bio Materials Chemistry-Chemistry (all)
CiteScore
9.40
自引率
2.10%
发文量
464
期刊最新文献
A Systematic Review of Sleep Disturbance in Idiopathic Intracranial Hypertension. Advancing Patient Education in Idiopathic Intracranial Hypertension: The Promise of Large Language Models. Anti-Myelin-Associated Glycoprotein Neuropathy: Recent Developments. Approach to Managing the Initial Presentation of Multiple Sclerosis: A Worldwide Practice Survey. Association Between LACE+ Index Risk Category and 90-Day Mortality After Stroke.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1