利用 VMD 和 Hurst 指数识别脑电信号中的眼球伪影。

Q3 Pharmacology, Toxicology and Pharmaceutics Journal of Basic and Clinical Physiology and Pharmacology Pub Date : 2024-10-24 DOI:10.1515/jbcpp-2024-0027
Amandeep Bisht, Preeti Singh, Pardeep Kaur, Geeta Dalal
{"title":"利用 VMD 和 Hurst 指数识别脑电信号中的眼球伪影。","authors":"Amandeep Bisht, Preeti Singh, Pardeep Kaur, Geeta Dalal","doi":"10.1515/jbcpp-2024-0027","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>Electroencephalographic (EEG) readings are usually infected with unavoidable artifacts, especially physiological ones. One such physiological artifact is the ocular artifacts (OAs) that are generally related to eyes and are characterized by high magnitude and a specific spike pattern in the prefrontal region of the brain. During the long-duration EEG acquisition, the retrieval of important information becomes quite complicated in prefrontal regions as ocular artifacts dominate the EEG recorded, making it difficult to discern underlying brain activity.</p><p><strong>Methods: </strong>With the progress and development in signal processing techniques, artifact handling has become a progressive field of investigation. This paper presents a framework for the detection and correction of ocular artifacts. This study emphasizes improving the quality and reducing the time complexity by using higher-order statistics (HOS) for artifact identification and variational mode decomposition (VMD) for OA correction.</p><p><strong>Results: </strong>An overall SNR of 14 dB, MAE of 0.09, and PSNR of 33.59 dB has been attained by the proposed framework.</p><p><strong>Conclusions: </strong>It was observed that the proposed HOS-VMD surpassed the state-of-the-art mode decomposition techniques.</p>","PeriodicalId":15352,"journal":{"name":"Journal of Basic and Clinical Physiology and Pharmacology","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-10-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Identification of ocular artifact in EEG signals using VMD and Hurst exponent.\",\"authors\":\"Amandeep Bisht, Preeti Singh, Pardeep Kaur, Geeta Dalal\",\"doi\":\"10.1515/jbcpp-2024-0027\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>Electroencephalographic (EEG) readings are usually infected with unavoidable artifacts, especially physiological ones. One such physiological artifact is the ocular artifacts (OAs) that are generally related to eyes and are characterized by high magnitude and a specific spike pattern in the prefrontal region of the brain. During the long-duration EEG acquisition, the retrieval of important information becomes quite complicated in prefrontal regions as ocular artifacts dominate the EEG recorded, making it difficult to discern underlying brain activity.</p><p><strong>Methods: </strong>With the progress and development in signal processing techniques, artifact handling has become a progressive field of investigation. This paper presents a framework for the detection and correction of ocular artifacts. This study emphasizes improving the quality and reducing the time complexity by using higher-order statistics (HOS) for artifact identification and variational mode decomposition (VMD) for OA correction.</p><p><strong>Results: </strong>An overall SNR of 14 dB, MAE of 0.09, and PSNR of 33.59 dB has been attained by the proposed framework.</p><p><strong>Conclusions: </strong>It was observed that the proposed HOS-VMD surpassed the state-of-the-art mode decomposition techniques.</p>\",\"PeriodicalId\":15352,\"journal\":{\"name\":\"Journal of Basic and Clinical Physiology and Pharmacology\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-10-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Basic and Clinical Physiology and Pharmacology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1515/jbcpp-2024-0027\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Pharmacology, Toxicology and Pharmaceutics\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Basic and Clinical Physiology and Pharmacology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1515/jbcpp-2024-0027","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Pharmacology, Toxicology and Pharmaceutics","Score":null,"Total":0}
引用次数: 0

摘要

目的:脑电图(EEG)读数通常会受到不可避免的伪影影响,尤其是生理伪影。其中一种生理伪影是眼球伪影(OAs),通常与眼睛有关,其特征是大脑前额叶区域的高幅度和特定尖峰模式。在长时间的脑电图采集过程中,前额叶区域的重要信息检索变得相当复杂,因为眼部伪影在脑电图记录中占主导地位,从而难以辨别潜在的大脑活动:随着信号处理技术的进步和发展,伪影处理已成为一个渐进的研究领域。本文提出了一个检测和校正眼部伪影的框架。本研究强调通过使用高阶统计(HOS)进行伪影识别和变异模式分解(VMD)进行 OA 校正来提高质量和降低时间复杂性:结果:拟议框架的总体信噪比为 14 dB,MAE 为 0.09,PSNR 为 33.59 dB:结论:据观察,拟议的 HOS-VMD 超越了最先进的模式分解技术。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Identification of ocular artifact in EEG signals using VMD and Hurst exponent.

Objectives: Electroencephalographic (EEG) readings are usually infected with unavoidable artifacts, especially physiological ones. One such physiological artifact is the ocular artifacts (OAs) that are generally related to eyes and are characterized by high magnitude and a specific spike pattern in the prefrontal region of the brain. During the long-duration EEG acquisition, the retrieval of important information becomes quite complicated in prefrontal regions as ocular artifacts dominate the EEG recorded, making it difficult to discern underlying brain activity.

Methods: With the progress and development in signal processing techniques, artifact handling has become a progressive field of investigation. This paper presents a framework for the detection and correction of ocular artifacts. This study emphasizes improving the quality and reducing the time complexity by using higher-order statistics (HOS) for artifact identification and variational mode decomposition (VMD) for OA correction.

Results: An overall SNR of 14 dB, MAE of 0.09, and PSNR of 33.59 dB has been attained by the proposed framework.

Conclusions: It was observed that the proposed HOS-VMD surpassed the state-of-the-art mode decomposition techniques.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Basic and Clinical Physiology and Pharmacology
Journal of Basic and Clinical Physiology and Pharmacology Pharmacology, Toxicology and Pharmaceutics-Pharmacology
CiteScore
3.90
自引率
0.00%
发文量
53
期刊介绍: The Journal of Basic and Clinical Physiology and Pharmacology (JBCPP) is a peer-reviewed bi-monthly published journal in experimental medicine. JBCPP publishes novel research in the physiological and pharmacological sciences, including brain research; cardiovascular-pulmonary interactions; exercise; thermal control; haematology; immune response; inflammation; metabolism; oxidative stress; and phytotherapy. As the borders between physiology, pharmacology and biochemistry become increasingly blurred, we also welcome papers using cutting-edge techniques in cellular and/or molecular biology to link descriptive or behavioral studies with cellular and molecular mechanisms underlying the integrative processes. Topics: Behavior and Neuroprotection, Reproduction, Genotoxicity and Cytotoxicity, Vascular Conditions, Cardiovascular Function, Cardiovascular-Pulmonary Interactions, Oxidative Stress, Metabolism, Immune Response, Hematological Profile, Inflammation, Infection, Phytotherapy.
期刊最新文献
Effect of omega-3 fatty acids supplementation on muscle mass, fat mass, and visceral fat of hemodialysis patients; A randomized clinical trial. Choroidal and retinal alteration after long-term use of tadalafil: a prospective non-randomized clinical trial. Immediate effect of sunlight exposure through blue glass on blood pressure in hypertensive patients: a randomized controlled trial. The alarming link between the COVID-19 pandemic and stroke: why ignoring this association after relapse of the disease has dangerous consequences. Identification of ocular artifact in EEG signals using VMD and Hurst exponent.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1