Marius Nicolae Popescu, Cristina Beiu, Carmen Andrada Iliescu, Andreea Racoviță, Mihai Berteanu, Mădălina Gabriela Iliescu, Ana Maria Alexandra Stănescu, Diana Sabina Radaschin, Liliana Gabriela Popa
{"title":"超声波引导下的肉毒杆菌毒素-A 注射用于医疗和美容目的。","authors":"Marius Nicolae Popescu, Cristina Beiu, Carmen Andrada Iliescu, Andreea Racoviță, Mihai Berteanu, Mădălina Gabriela Iliescu, Ana Maria Alexandra Stănescu, Diana Sabina Radaschin, Liliana Gabriela Popa","doi":"10.3390/toxins16100413","DOIUrl":null,"url":null,"abstract":"<p><p>With the increasing use of Botulinum toxin type A (BoNT-A) injections in the masseter muscles for both medical and aesthetic purposes, there is a constant need to continually enhance the efficacy of these treatments and reduce the risk of potential adverse events. This review provides an in-depth analysis of the masseter muscle's anatomical structure and essential landmarks and emphasizes the advantages of ultrasound (US) guidance in improving the precision of BoNT-A injections compared to conventional blind methods. The review is supplemented with comprehensive figures, including graphics, clinical images, and ultrasound visuals, to support the discussion. Potential complications such as paradoxical bulging, inadvertent injections into the risorius muscle or parotid gland, facial paralysis, and the risk of bone resorption are examined. Future research should aim at refining injection techniques and assessing the long-term effects of repeated treatments to ensure optimal patient care and safety.</p>","PeriodicalId":3,"journal":{"name":"ACS Applied Electronic Materials","volume":null,"pages":null},"PeriodicalIF":4.3000,"publicationDate":"2024-09-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11511025/pdf/","citationCount":"0","resultStr":"{\"title\":\"Ultrasound-Guided Botulinum Toxin-A Injections into the Masseter Muscle for Both Medical and Aesthetic Purposes.\",\"authors\":\"Marius Nicolae Popescu, Cristina Beiu, Carmen Andrada Iliescu, Andreea Racoviță, Mihai Berteanu, Mădălina Gabriela Iliescu, Ana Maria Alexandra Stănescu, Diana Sabina Radaschin, Liliana Gabriela Popa\",\"doi\":\"10.3390/toxins16100413\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>With the increasing use of Botulinum toxin type A (BoNT-A) injections in the masseter muscles for both medical and aesthetic purposes, there is a constant need to continually enhance the efficacy of these treatments and reduce the risk of potential adverse events. This review provides an in-depth analysis of the masseter muscle's anatomical structure and essential landmarks and emphasizes the advantages of ultrasound (US) guidance in improving the precision of BoNT-A injections compared to conventional blind methods. The review is supplemented with comprehensive figures, including graphics, clinical images, and ultrasound visuals, to support the discussion. Potential complications such as paradoxical bulging, inadvertent injections into the risorius muscle or parotid gland, facial paralysis, and the risk of bone resorption are examined. Future research should aim at refining injection techniques and assessing the long-term effects of repeated treatments to ensure optimal patient care and safety.</p>\",\"PeriodicalId\":3,\"journal\":{\"name\":\"ACS Applied Electronic Materials\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":4.3000,\"publicationDate\":\"2024-09-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11511025/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACS Applied Electronic Materials\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.3390/toxins16100413\",\"RegionNum\":3,\"RegionCategory\":\"材料科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Electronic Materials","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3390/toxins16100413","RegionNum":3,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0
摘要
随着 A 型肉毒杆菌毒素(BoNT-A)注射在颌下肌肉中的应用越来越多,无论是出于医疗还是美容目的,都需要不断提高这些治疗的疗效并降低潜在不良事件的风险。本综述深入分析了咀嚼肌的解剖结构和重要标志,并强调了与传统盲法相比,超声波(US)引导在提高 BoNT-A 注射精确度方面的优势。该综述辅以全面的图表,包括图形、临床图像和超声波视觉效果,以支持讨论。研究还探讨了潜在的并发症,如矛盾性隆起、不慎注射到梨状肌或腮腺、面瘫以及骨吸收的风险。未来的研究应着眼于改进注射技术和评估重复治疗的长期效果,以确保最佳的患者护理和安全性。
Ultrasound-Guided Botulinum Toxin-A Injections into the Masseter Muscle for Both Medical and Aesthetic Purposes.
With the increasing use of Botulinum toxin type A (BoNT-A) injections in the masseter muscles for both medical and aesthetic purposes, there is a constant need to continually enhance the efficacy of these treatments and reduce the risk of potential adverse events. This review provides an in-depth analysis of the masseter muscle's anatomical structure and essential landmarks and emphasizes the advantages of ultrasound (US) guidance in improving the precision of BoNT-A injections compared to conventional blind methods. The review is supplemented with comprehensive figures, including graphics, clinical images, and ultrasound visuals, to support the discussion. Potential complications such as paradoxical bulging, inadvertent injections into the risorius muscle or parotid gland, facial paralysis, and the risk of bone resorption are examined. Future research should aim at refining injection techniques and assessing the long-term effects of repeated treatments to ensure optimal patient care and safety.