基于 CFD 的车厢火灾冷却阶段热电偶测量值与局部气体温度之间的偏差分析

IF 3.4 3区 工程技术 Q2 ENGINEERING, CIVIL Fire Safety Journal Pub Date : 2024-10-17 DOI:10.1016/j.firesaf.2024.104276
Florian Put , Andrea Lucherini , Ruben Van Coile , Bart Merci
{"title":"基于 CFD 的车厢火灾冷却阶段热电偶测量值与局部气体温度之间的偏差分析","authors":"Florian Put ,&nbsp;Andrea Lucherini ,&nbsp;Ruben Van Coile ,&nbsp;Bart Merci","doi":"10.1016/j.firesaf.2024.104276","DOIUrl":null,"url":null,"abstract":"<div><div>Data from thermocouple (TC) measurements play a pivotal role in fire safety science and engineering studies. It is well-known that there are deviations from the actual local gas temperature and many studies have led to the development of correction factors. The present study focuses on these deviations inside compartments through a systematic series of CFD simulations, performed with Fire Dynamics Simulator (FDS), version 6.8.0. A canonical cubic box is used as geometry. This allows for the demonstration of the impact of the presence of smoke, with variable optical thickness, on the TC data as retrieved from FDS. Significant differences are observed between TC measurements and local gas temperatures. Corrections as developed for TC measurements in open atmospheres cannot be readily applied in compartment configurations, where smoke properties change both spatially and temporally.</div></div>","PeriodicalId":50445,"journal":{"name":"Fire Safety Journal","volume":null,"pages":null},"PeriodicalIF":3.4000,"publicationDate":"2024-10-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"CFD-based analysis of deviations between thermocouple measurements and local gas temperatures during the cooling phase of compartment fires\",\"authors\":\"Florian Put ,&nbsp;Andrea Lucherini ,&nbsp;Ruben Van Coile ,&nbsp;Bart Merci\",\"doi\":\"10.1016/j.firesaf.2024.104276\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>Data from thermocouple (TC) measurements play a pivotal role in fire safety science and engineering studies. It is well-known that there are deviations from the actual local gas temperature and many studies have led to the development of correction factors. The present study focuses on these deviations inside compartments through a systematic series of CFD simulations, performed with Fire Dynamics Simulator (FDS), version 6.8.0. A canonical cubic box is used as geometry. This allows for the demonstration of the impact of the presence of smoke, with variable optical thickness, on the TC data as retrieved from FDS. Significant differences are observed between TC measurements and local gas temperatures. Corrections as developed for TC measurements in open atmospheres cannot be readily applied in compartment configurations, where smoke properties change both spatially and temporally.</div></div>\",\"PeriodicalId\":50445,\"journal\":{\"name\":\"Fire Safety Journal\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":3.4000,\"publicationDate\":\"2024-10-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Fire Safety Journal\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0379711224001899\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENGINEERING, CIVIL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Fire Safety Journal","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0379711224001899","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, CIVIL","Score":null,"Total":0}
引用次数: 0

摘要

热电偶 (TC) 测量数据在消防安全科学和工程研究中发挥着举足轻重的作用。众所周知,当地气体温度与实际温度存在偏差,因此许多研究都开发了校正系数。本研究通过使用火灾动力学模拟器(FDS)6.8.0 版进行一系列系统的 CFD 模拟,重点研究隔间内的这些偏差。模拟使用了一个典型的立方体盒子作为几何体。这样就可以证明存在不同光学厚度的烟雾对从 FDS 获取的 TC 数据的影响。TC 测量值与当地气体温度之间存在显著差异。为开放大气中的 TC 测量而开发的校正方法不能轻易应用于隔室配置中,因为烟雾特性在空间和时间上都会发生变化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
CFD-based analysis of deviations between thermocouple measurements and local gas temperatures during the cooling phase of compartment fires
Data from thermocouple (TC) measurements play a pivotal role in fire safety science and engineering studies. It is well-known that there are deviations from the actual local gas temperature and many studies have led to the development of correction factors. The present study focuses on these deviations inside compartments through a systematic series of CFD simulations, performed with Fire Dynamics Simulator (FDS), version 6.8.0. A canonical cubic box is used as geometry. This allows for the demonstration of the impact of the presence of smoke, with variable optical thickness, on the TC data as retrieved from FDS. Significant differences are observed between TC measurements and local gas temperatures. Corrections as developed for TC measurements in open atmospheres cannot be readily applied in compartment configurations, where smoke properties change both spatially and temporally.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Fire Safety Journal
Fire Safety Journal 工程技术-材料科学:综合
CiteScore
5.70
自引率
9.70%
发文量
153
审稿时长
60 days
期刊介绍: Fire Safety Journal is the leading publication dealing with all aspects of fire safety engineering. Its scope is purposefully wide, as it is deemed important to encourage papers from all sources within this multidisciplinary subject, thus providing a forum for its further development as a distinct engineering discipline. This is an essential step towards gaining a status equal to that enjoyed by the other engineering disciplines.
期刊最新文献
Bench-scale thermomechanical assessment of carbon fibre reinforced polymer C-channels Post-fire residual mechanical properties of Q460GJ steel under different pre-tensile stresses Statistical variation of the burning rate and extinction characteristics of engineered timber products Performance fire tests on building external walls made of sandwich panels On gravity-driven liquid nitrogen jets reach and horizontal spread for extinction of ground fires by aerial means
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1