{"title":"直接空气捕集与低碳供热的整合:工艺工程和电力系统分析","authors":"Aniruddh Mohan ,&nbsp;Fangwei Cheng ,&nbsp;Hongxi Luo ,&nbsp;Chris Greig ,&nbsp;Eric Larson ,&nbsp;Jesse D. Jenkins","doi":"10.1016/j.enconman.2024.119136","DOIUrl":null,"url":null,"abstract":"<div><div>Direct air capture (DAC) of carbon dioxide (CO<sub>2</sub>) is energy intensive given the low concentration (<span><math><mo>&lt;</mo></math></span>0.1%) of CO<sub>2</sub> in ambient air, but offers relatively strong verification of removals and limited land constraints to scale. Lower temperature solid sorbent based DAC could be coupled on-site with low carbon thermal generators such as nuclear power plants. Here, we undertake a unique interdisciplinary study combining process engineering with a detailed macro-energy system optimization model to evaluate the system-level impacts of such plant designs in the Texas electricity system. We contrast this with using grid power to operate a heat pump to regenerate the sorbent. Our analysis identifies net carbon removal costs accounting for power system impacts and resulting indirect CO<span><math><msub><mrow></mrow><mrow><mn>2</mn></mrow></msub></math></span> emissions from DAC energy consumption. We find that inefficient configurations of DAC at a nuclear power plant can lead to increases in power sector emissions relative to a case without DAC, at a scale that would cancel out almost 50% of the carbon removal from DAC. Net removal costs for the most efficient configurations increase by roughly 18% once indirect power system-level impacts are considered, though this is comparable to the indirect systems-level emissions from operating grid-powered heat pumps for sorbent regeneration. Our study therefore highlights the need for DAC energy procurement to be guided by consideration of indirect emission impacts on the electricity system. Finally, DAC could potentially create demand pull for zero carbon firm generation, accelerating decarbonization relative to a world without such DAC deployment. We find that DAC operators would have to be willing to pay existing or new nuclear power plants roughly $30–80/tCO<sub>2</sub> or $150–400/tCO<sub>2</sub> respectively, for input energy, to enable nuclear plants to be economically competitive in least cost electricity markets that do not have carbon constraints or subsidies for nuclear energy.</div></div>","PeriodicalId":11664,"journal":{"name":"Energy Conversion and Management","volume":"322 ","pages":"Article 119136"},"PeriodicalIF":9.9000,"publicationDate":"2024-10-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Direct air capture integration with low-carbon heat: Process engineering and power system analysis\",\"authors\":\"Aniruddh Mohan ,&nbsp;Fangwei Cheng ,&nbsp;Hongxi Luo ,&nbsp;Chris Greig ,&nbsp;Eric Larson ,&nbsp;Jesse D. Jenkins\",\"doi\":\"10.1016/j.enconman.2024.119136\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>Direct air capture (DAC) of carbon dioxide (CO<sub>2</sub>) is energy intensive given the low concentration (<span><math><mo>&lt;</mo></math></span>0.1%) of CO<sub>2</sub> in ambient air, but offers relatively strong verification of removals and limited land constraints to scale. Lower temperature solid sorbent based DAC could be coupled on-site with low carbon thermal generators such as nuclear power plants. Here, we undertake a unique interdisciplinary study combining process engineering with a detailed macro-energy system optimization model to evaluate the system-level impacts of such plant designs in the Texas electricity system. We contrast this with using grid power to operate a heat pump to regenerate the sorbent. Our analysis identifies net carbon removal costs accounting for power system impacts and resulting indirect CO<span><math><msub><mrow></mrow><mrow><mn>2</mn></mrow></msub></math></span> emissions from DAC energy consumption. We find that inefficient configurations of DAC at a nuclear power plant can lead to increases in power sector emissions relative to a case without DAC, at a scale that would cancel out almost 50% of the carbon removal from DAC. Net removal costs for the most efficient configurations increase by roughly 18% once indirect power system-level impacts are considered, though this is comparable to the indirect systems-level emissions from operating grid-powered heat pumps for sorbent regeneration. Our study therefore highlights the need for DAC energy procurement to be guided by consideration of indirect emission impacts on the electricity system. Finally, DAC could potentially create demand pull for zero carbon firm generation, accelerating decarbonization relative to a world without such DAC deployment. We find that DAC operators would have to be willing to pay existing or new nuclear power plants roughly $30–80/tCO<sub>2</sub> or $150–400/tCO<sub>2</sub> respectively, for input energy, to enable nuclear plants to be economically competitive in least cost electricity markets that do not have carbon constraints or subsidies for nuclear energy.</div></div>\",\"PeriodicalId\":11664,\"journal\":{\"name\":\"Energy Conversion and Management\",\"volume\":\"322 \",\"pages\":\"Article 119136\"},\"PeriodicalIF\":9.9000,\"publicationDate\":\"2024-10-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Energy Conversion and Management\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S019689042401077X\",\"RegionNum\":1,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ENERGY & FUELS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Energy Conversion and Management","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S019689042401077X","RegionNum":1,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENERGY & FUELS","Score":null,"Total":0}
引用次数: 0

摘要

鉴于环境空气中二氧化碳的浓度较低(0.1%),二氧化碳(CO2)的直接空气捕集(DAC)是一种能源密集型技术,但它能提供相对较强的清除验证,而且对规模化的土地限制有限。基于低温固体吸附剂的 DAC 可与核电站等低碳热能发电机现场耦合。在此,我们开展了一项独特的跨学科研究,将工艺工程与详细的宏观能源系统优化模型相结合,以评估此类工厂设计在德克萨斯州电力系统中的系统级影响。我们将其与使用电网电力运行热泵来再生吸附剂的方法进行了对比。我们的分析确定了净碳清除成本,考虑了电力系统的影响以及 DAC 能源消耗所产生的间接二氧化碳排放。我们发现,相对于不使用 DAC 的情况,核电厂 DAC 的低效配置会导致电力部门排放量的增加,其规模将抵消 DAC 近 50% 的碳去除量。一旦考虑到间接的电力系统级影响,最高效配置的净去除成本大约会增加 18%,不过这与运行电网热泵进行吸附剂再生所产生的间接系统级排放相当。因此,我们的研究强调了 DAC 能源采购需要考虑对电力系统的间接排放影响。最后,DAC 有可能产生对零碳固定发电的需求拉动,与没有部署 DAC 的世界相比,可加速去碳化。我们发现,DAC 运营商必须愿意为现有或新建核电厂的输入能源分别支付大约 30-80 美元/吨 CO2 或 150-400 美元/吨 CO2 的费用,才能使核电厂在没有碳约束或核能补贴的最低成本电力市场中具有经济竞争力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Direct air capture integration with low-carbon heat: Process engineering and power system analysis
Direct air capture (DAC) of carbon dioxide (CO2) is energy intensive given the low concentration (<0.1%) of CO2 in ambient air, but offers relatively strong verification of removals and limited land constraints to scale. Lower temperature solid sorbent based DAC could be coupled on-site with low carbon thermal generators such as nuclear power plants. Here, we undertake a unique interdisciplinary study combining process engineering with a detailed macro-energy system optimization model to evaluate the system-level impacts of such plant designs in the Texas electricity system. We contrast this with using grid power to operate a heat pump to regenerate the sorbent. Our analysis identifies net carbon removal costs accounting for power system impacts and resulting indirect CO2 emissions from DAC energy consumption. We find that inefficient configurations of DAC at a nuclear power plant can lead to increases in power sector emissions relative to a case without DAC, at a scale that would cancel out almost 50% of the carbon removal from DAC. Net removal costs for the most efficient configurations increase by roughly 18% once indirect power system-level impacts are considered, though this is comparable to the indirect systems-level emissions from operating grid-powered heat pumps for sorbent regeneration. Our study therefore highlights the need for DAC energy procurement to be guided by consideration of indirect emission impacts on the electricity system. Finally, DAC could potentially create demand pull for zero carbon firm generation, accelerating decarbonization relative to a world without such DAC deployment. We find that DAC operators would have to be willing to pay existing or new nuclear power plants roughly $30–80/tCO2 or $150–400/tCO2 respectively, for input energy, to enable nuclear plants to be economically competitive in least cost electricity markets that do not have carbon constraints or subsidies for nuclear energy.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Energy Conversion and Management
Energy Conversion and Management 工程技术-力学
CiteScore
19.00
自引率
11.50%
发文量
1304
审稿时长
17 days
期刊介绍: The journal Energy Conversion and Management provides a forum for publishing original contributions and comprehensive technical review articles of interdisciplinary and original research on all important energy topics. The topics considered include energy generation, utilization, conversion, storage, transmission, conservation, management and sustainability. These topics typically involve various types of energy such as mechanical, thermal, nuclear, chemical, electromagnetic, magnetic and electric. These energy types cover all known energy resources, including renewable resources (e.g., solar, bio, hydro, wind, geothermal and ocean energy), fossil fuels and nuclear resources.
期刊最新文献
Stabilizing ignition and enhancing combustion within pre-chamber jet by integrating microwave-assisted ignition A novel high-speed homogenizer assisted process intensification technique for biodiesel production using soya acid oil: Process optimization, kinetic and thermodynamic modelling Development of a novel tool to simulate solar thermal cogeneration plants using small-capacity tower plants The effects of the location of the leading-edge tubercles on the performance of horizontal axis wind turbine Dual-mode arrayed vibration-wind piezoelectric energy harvester
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1