{"title":"基于适当正交分解的附带通风设备的高海拔哨兵建筑室内热环境优化","authors":"Linfeng Liang , Meng Zhao , Yukun Wang , Zhengwei Long , Haiguo Yin","doi":"10.1016/j.buildenv.2024.112200","DOIUrl":null,"url":null,"abstract":"<div><div>The low-oxygen and severe cold climate characteristics of high-altitude regions significantly impact individuals' physiological health and thermal comfort inside buildings, especially for sentry buildings where the enclosure is fully exposed to the outdoors. This study aimed to optimize the indoor environment for high-altitude sentry buildings with attached ventilation. Firstly, the optimal location of exhaust outlets and oxygen sources in the heating mode of high-altitude sentry buildings was studied, and it showed high performance in terms of thermal comfort and energy efficiency. Additionally, the POD method and interpolation methods were applied to expand the sample dataset and identify the optimal combination of attached ventilation parameters and oxygen supply concentration, creating a comfortable, oxygen-enriched environment within the sentry buildings while also considering energy efficiency. The results indicate that when the optimization objective is weighted towards thermal comfort, the percentage of dissatisfied (PD) and the draught rate (DR) values under the optimal scheme are reduced by 82 % and 46.6 %, respectively, compared to previous studies. However, when the emphasis is on energy efficiency in environmental optimization, the air supply energy under the optimal scheme has a 64.4 % reduction compared to previous research results. When considering both optimization objectives simultaneously, the PD and DR values under the optimal scheme are reduced by 35.9 % and 96.9 %, respectively, compared to previous research results. These results demonstrate significant improvements in both thermal comfort and energy efficiency relative to our previous study.</div></div>","PeriodicalId":9273,"journal":{"name":"Building and Environment","volume":"267 ","pages":"Article 112200"},"PeriodicalIF":7.1000,"publicationDate":"2024-10-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Optimization of indoor thermal environment for high-altitude sentry buildings with attached ventilation based on proper orthogonal decomposition\",\"authors\":\"Linfeng Liang , Meng Zhao , Yukun Wang , Zhengwei Long , Haiguo Yin\",\"doi\":\"10.1016/j.buildenv.2024.112200\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>The low-oxygen and severe cold climate characteristics of high-altitude regions significantly impact individuals' physiological health and thermal comfort inside buildings, especially for sentry buildings where the enclosure is fully exposed to the outdoors. This study aimed to optimize the indoor environment for high-altitude sentry buildings with attached ventilation. Firstly, the optimal location of exhaust outlets and oxygen sources in the heating mode of high-altitude sentry buildings was studied, and it showed high performance in terms of thermal comfort and energy efficiency. Additionally, the POD method and interpolation methods were applied to expand the sample dataset and identify the optimal combination of attached ventilation parameters and oxygen supply concentration, creating a comfortable, oxygen-enriched environment within the sentry buildings while also considering energy efficiency. The results indicate that when the optimization objective is weighted towards thermal comfort, the percentage of dissatisfied (PD) and the draught rate (DR) values under the optimal scheme are reduced by 82 % and 46.6 %, respectively, compared to previous studies. However, when the emphasis is on energy efficiency in environmental optimization, the air supply energy under the optimal scheme has a 64.4 % reduction compared to previous research results. When considering both optimization objectives simultaneously, the PD and DR values under the optimal scheme are reduced by 35.9 % and 96.9 %, respectively, compared to previous research results. These results demonstrate significant improvements in both thermal comfort and energy efficiency relative to our previous study.</div></div>\",\"PeriodicalId\":9273,\"journal\":{\"name\":\"Building and Environment\",\"volume\":\"267 \",\"pages\":\"Article 112200\"},\"PeriodicalIF\":7.1000,\"publicationDate\":\"2024-10-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Building and Environment\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0360132324010424\",\"RegionNum\":1,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CONSTRUCTION & BUILDING TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Building and Environment","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0360132324010424","RegionNum":1,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
引用次数: 0
摘要
高海拔地区低氧和严寒的气候特征对人的生理健康和建筑物内的热舒适度有很大影响,尤其是对于围墙完全暴露在室外的哨所建筑。本研究旨在优化附带通风设备的高海拔哨所建筑的室内环境。首先,研究了高海拔哨所建筑供暖模式下排气口和氧气源的最佳位置,结果表明其在热舒适性和能源效率方面都有很高的表现。此外,应用 POD 法和插值法扩大样本数据集,确定附着通风参数和供氧浓度的最佳组合,在哨所建筑内创造舒适的富氧环境,同时兼顾能源效率。结果表明,当优化目标偏重于热舒适度时,与之前的研究相比,最优方案下的不满意度(PD)和吃风率(DR)值分别降低了 82% 和 46.6%。然而,当环境优化的重点放在能源效率上时,优化方案下的送风能耗与之前的研究结果相比降低了 64.4%。当同时考虑两个优化目标时,优化方案下的 PD 值和 DR 值与之前的研究结果相比分别降低了 35.9% 和 96.9%。这些结果表明,与我们之前的研究相比,热舒适度和能源效率都有了显著提高。
Optimization of indoor thermal environment for high-altitude sentry buildings with attached ventilation based on proper orthogonal decomposition
The low-oxygen and severe cold climate characteristics of high-altitude regions significantly impact individuals' physiological health and thermal comfort inside buildings, especially for sentry buildings where the enclosure is fully exposed to the outdoors. This study aimed to optimize the indoor environment for high-altitude sentry buildings with attached ventilation. Firstly, the optimal location of exhaust outlets and oxygen sources in the heating mode of high-altitude sentry buildings was studied, and it showed high performance in terms of thermal comfort and energy efficiency. Additionally, the POD method and interpolation methods were applied to expand the sample dataset and identify the optimal combination of attached ventilation parameters and oxygen supply concentration, creating a comfortable, oxygen-enriched environment within the sentry buildings while also considering energy efficiency. The results indicate that when the optimization objective is weighted towards thermal comfort, the percentage of dissatisfied (PD) and the draught rate (DR) values under the optimal scheme are reduced by 82 % and 46.6 %, respectively, compared to previous studies. However, when the emphasis is on energy efficiency in environmental optimization, the air supply energy under the optimal scheme has a 64.4 % reduction compared to previous research results. When considering both optimization objectives simultaneously, the PD and DR values under the optimal scheme are reduced by 35.9 % and 96.9 %, respectively, compared to previous research results. These results demonstrate significant improvements in both thermal comfort and energy efficiency relative to our previous study.
期刊介绍:
Building and Environment, an international journal, is dedicated to publishing original research papers, comprehensive review articles, editorials, and short communications in the fields of building science, urban physics, and human interaction with the indoor and outdoor built environment. The journal emphasizes innovative technologies and knowledge verified through measurement and analysis. It covers environmental performance across various spatial scales, from cities and communities to buildings and systems, fostering collaborative, multi-disciplinary research with broader significance.