基于适当正交分解的附带通风设备的高海拔哨兵建筑室内热环境优化

IF 7.1 1区 工程技术 Q1 CONSTRUCTION & BUILDING TECHNOLOGY Building and Environment Pub Date : 2024-10-18 DOI:10.1016/j.buildenv.2024.112200
Linfeng Liang , Meng Zhao , Yukun Wang , Zhengwei Long , Haiguo Yin
{"title":"基于适当正交分解的附带通风设备的高海拔哨兵建筑室内热环境优化","authors":"Linfeng Liang ,&nbsp;Meng Zhao ,&nbsp;Yukun Wang ,&nbsp;Zhengwei Long ,&nbsp;Haiguo Yin","doi":"10.1016/j.buildenv.2024.112200","DOIUrl":null,"url":null,"abstract":"<div><div>The low-oxygen and severe cold climate characteristics of high-altitude regions significantly impact individuals' physiological health and thermal comfort inside buildings, especially for sentry buildings where the enclosure is fully exposed to the outdoors. This study aimed to optimize the indoor environment for high-altitude sentry buildings with attached ventilation. Firstly, the optimal location of exhaust outlets and oxygen sources in the heating mode of high-altitude sentry buildings was studied, and it showed high performance in terms of thermal comfort and energy efficiency. Additionally, the POD method and interpolation methods were applied to expand the sample dataset and identify the optimal combination of attached ventilation parameters and oxygen supply concentration, creating a comfortable, oxygen-enriched environment within the sentry buildings while also considering energy efficiency. The results indicate that when the optimization objective is weighted towards thermal comfort, the percentage of dissatisfied (PD) and the draught rate (DR) values under the optimal scheme are reduced by 82 % and 46.6 %, respectively, compared to previous studies. However, when the emphasis is on energy efficiency in environmental optimization, the air supply energy under the optimal scheme has a 64.4 % reduction compared to previous research results. When considering both optimization objectives simultaneously, the PD and DR values under the optimal scheme are reduced by 35.9 % and 96.9 %, respectively, compared to previous research results. These results demonstrate significant improvements in both thermal comfort and energy efficiency relative to our previous study.</div></div>","PeriodicalId":9273,"journal":{"name":"Building and Environment","volume":"267 ","pages":"Article 112200"},"PeriodicalIF":7.1000,"publicationDate":"2024-10-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Optimization of indoor thermal environment for high-altitude sentry buildings with attached ventilation based on proper orthogonal decomposition\",\"authors\":\"Linfeng Liang ,&nbsp;Meng Zhao ,&nbsp;Yukun Wang ,&nbsp;Zhengwei Long ,&nbsp;Haiguo Yin\",\"doi\":\"10.1016/j.buildenv.2024.112200\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>The low-oxygen and severe cold climate characteristics of high-altitude regions significantly impact individuals' physiological health and thermal comfort inside buildings, especially for sentry buildings where the enclosure is fully exposed to the outdoors. This study aimed to optimize the indoor environment for high-altitude sentry buildings with attached ventilation. Firstly, the optimal location of exhaust outlets and oxygen sources in the heating mode of high-altitude sentry buildings was studied, and it showed high performance in terms of thermal comfort and energy efficiency. Additionally, the POD method and interpolation methods were applied to expand the sample dataset and identify the optimal combination of attached ventilation parameters and oxygen supply concentration, creating a comfortable, oxygen-enriched environment within the sentry buildings while also considering energy efficiency. The results indicate that when the optimization objective is weighted towards thermal comfort, the percentage of dissatisfied (PD) and the draught rate (DR) values under the optimal scheme are reduced by 82 % and 46.6 %, respectively, compared to previous studies. However, when the emphasis is on energy efficiency in environmental optimization, the air supply energy under the optimal scheme has a 64.4 % reduction compared to previous research results. When considering both optimization objectives simultaneously, the PD and DR values under the optimal scheme are reduced by 35.9 % and 96.9 %, respectively, compared to previous research results. These results demonstrate significant improvements in both thermal comfort and energy efficiency relative to our previous study.</div></div>\",\"PeriodicalId\":9273,\"journal\":{\"name\":\"Building and Environment\",\"volume\":\"267 \",\"pages\":\"Article 112200\"},\"PeriodicalIF\":7.1000,\"publicationDate\":\"2024-10-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Building and Environment\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0360132324010424\",\"RegionNum\":1,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CONSTRUCTION & BUILDING TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Building and Environment","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0360132324010424","RegionNum":1,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

高海拔地区低氧和严寒的气候特征对人的生理健康和建筑物内的热舒适度有很大影响,尤其是对于围墙完全暴露在室外的哨所建筑。本研究旨在优化附带通风设备的高海拔哨所建筑的室内环境。首先,研究了高海拔哨所建筑供暖模式下排气口和氧气源的最佳位置,结果表明其在热舒适性和能源效率方面都有很高的表现。此外,应用 POD 法和插值法扩大样本数据集,确定附着通风参数和供氧浓度的最佳组合,在哨所建筑内创造舒适的富氧环境,同时兼顾能源效率。结果表明,当优化目标偏重于热舒适度时,与之前的研究相比,最优方案下的不满意度(PD)和吃风率(DR)值分别降低了 82% 和 46.6%。然而,当环境优化的重点放在能源效率上时,优化方案下的送风能耗与之前的研究结果相比降低了 64.4%。当同时考虑两个优化目标时,优化方案下的 PD 值和 DR 值与之前的研究结果相比分别降低了 35.9% 和 96.9%。这些结果表明,与我们之前的研究相比,热舒适度和能源效率都有了显著提高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Optimization of indoor thermal environment for high-altitude sentry buildings with attached ventilation based on proper orthogonal decomposition
The low-oxygen and severe cold climate characteristics of high-altitude regions significantly impact individuals' physiological health and thermal comfort inside buildings, especially for sentry buildings where the enclosure is fully exposed to the outdoors. This study aimed to optimize the indoor environment for high-altitude sentry buildings with attached ventilation. Firstly, the optimal location of exhaust outlets and oxygen sources in the heating mode of high-altitude sentry buildings was studied, and it showed high performance in terms of thermal comfort and energy efficiency. Additionally, the POD method and interpolation methods were applied to expand the sample dataset and identify the optimal combination of attached ventilation parameters and oxygen supply concentration, creating a comfortable, oxygen-enriched environment within the sentry buildings while also considering energy efficiency. The results indicate that when the optimization objective is weighted towards thermal comfort, the percentage of dissatisfied (PD) and the draught rate (DR) values under the optimal scheme are reduced by 82 % and 46.6 %, respectively, compared to previous studies. However, when the emphasis is on energy efficiency in environmental optimization, the air supply energy under the optimal scheme has a 64.4 % reduction compared to previous research results. When considering both optimization objectives simultaneously, the PD and DR values under the optimal scheme are reduced by 35.9 % and 96.9 %, respectively, compared to previous research results. These results demonstrate significant improvements in both thermal comfort and energy efficiency relative to our previous study.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Building and Environment
Building and Environment 工程技术-工程:环境
CiteScore
12.50
自引率
23.00%
发文量
1130
审稿时长
27 days
期刊介绍: Building and Environment, an international journal, is dedicated to publishing original research papers, comprehensive review articles, editorials, and short communications in the fields of building science, urban physics, and human interaction with the indoor and outdoor built environment. The journal emphasizes innovative technologies and knowledge verified through measurement and analysis. It covers environmental performance across various spatial scales, from cities and communities to buildings and systems, fostering collaborative, multi-disciplinary research with broader significance.
期刊最新文献
Editorial Board Validation of large eddy simulations in urban wind studies using a new overall area metric Assessment of dust endotoxins, airborne bacteria, and PM2.5 at old-age nursing homes and children's daycare centers in the Seoul metropolitan area, South Korea Contextual evaluation of the impact of dynamic urban window view content on view satisfaction Challenges and future directions in evaporative cooling: Balancing sustainable cooling with microbial safety
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1