使用带袖带的气管导管对气道过敏的儿科患者术后拔管相关呼吸系统不良事件发生率的影响:一项回顾性队列研究。

IF 2.8 3区 医学 Q2 ANESTHESIOLOGY Journal of Anesthesia Pub Date : 2024-10-29 DOI:10.1007/s00540-024-03423-4
Kazuma Sasaki, Jun Takeshita, Sayaka Nakamura, Kazuya Tachibana
{"title":"使用带袖带的气管导管对气道过敏的儿科患者术后拔管相关呼吸系统不良事件发生率的影响:一项回顾性队列研究。","authors":"Kazuma Sasaki, Jun Takeshita, Sayaka Nakamura, Kazuya Tachibana","doi":"10.1007/s00540-024-03423-4","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Whether endotracheal tube (ETT) configuration (cuffed or uncuffed) influences the occurrence of respiratory adverse events (RAEs) in patients at risk remains largely unknown. We investigated the effects of cuffed ETTs on RAE occurrence after extubation in pediatric patients with airway hypersensitivity.</p><p><strong>Methods: </strong>Children aged < 8 years with increased airway hypersensitivity (defined as upper airway symptoms, recent upper respiratory infection within 2 weeks, or a history of asthma) who underwent general endotracheal anesthesia with inhaled agents between January 2021 and December 2022 were included. We retrospectively examined the patients' background and intraoperative anesthesia conditions by comparing the cuffed and uncuffed ETT groups. Multiple logistic regression analysis was performed to estimate the association between ETT configuration (cuffed vs. uncuffed) and the occurrence of RAEs or respiratory interventions (laryngospasm, peripheral capillary oxygen saturation < 92%, oxygen supplementation, epinephrine inhalation, or reintubation) after extubation.</p><p><strong>Results: </strong>Cuffed ETTs were used in 163 patients and uncuffed ETTs in 143 patients. Apart from the frequency of upper airway surgery and intraoperative fluid balance, no significant differences in background characteristics were observed between the groups. RAEs after extubation were observed in 36 (22.1%) and 28 (19.6%) patients in each cuffed and uncuffed ETT groups. After adjusting for known RAE risk factors, no difference was observed in RAEs or respiratory interventions after extubation between both groups (odds ratio, 1.14; 95% confidence interval: 0.64, 2.06).</p><p><strong>Conclusion: </strong>In pediatric patients with airway hypersensitivity, the use of cuffed ETTs did not increase the occurrence of RAEs or respiratory interventions after extubation.</p>","PeriodicalId":14997,"journal":{"name":"Journal of Anesthesia","volume":" ","pages":""},"PeriodicalIF":2.8000,"publicationDate":"2024-10-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Effect of use of cuffed endotracheal tubes on the occurrence of postoperative extubation-related respiratory adverse events in pediatric patients with airway hypersensitivity: a retrospective cohort study.\",\"authors\":\"Kazuma Sasaki, Jun Takeshita, Sayaka Nakamura, Kazuya Tachibana\",\"doi\":\"10.1007/s00540-024-03423-4\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>Whether endotracheal tube (ETT) configuration (cuffed or uncuffed) influences the occurrence of respiratory adverse events (RAEs) in patients at risk remains largely unknown. We investigated the effects of cuffed ETTs on RAE occurrence after extubation in pediatric patients with airway hypersensitivity.</p><p><strong>Methods: </strong>Children aged < 8 years with increased airway hypersensitivity (defined as upper airway symptoms, recent upper respiratory infection within 2 weeks, or a history of asthma) who underwent general endotracheal anesthesia with inhaled agents between January 2021 and December 2022 were included. We retrospectively examined the patients' background and intraoperative anesthesia conditions by comparing the cuffed and uncuffed ETT groups. Multiple logistic regression analysis was performed to estimate the association between ETT configuration (cuffed vs. uncuffed) and the occurrence of RAEs or respiratory interventions (laryngospasm, peripheral capillary oxygen saturation < 92%, oxygen supplementation, epinephrine inhalation, or reintubation) after extubation.</p><p><strong>Results: </strong>Cuffed ETTs were used in 163 patients and uncuffed ETTs in 143 patients. Apart from the frequency of upper airway surgery and intraoperative fluid balance, no significant differences in background characteristics were observed between the groups. RAEs after extubation were observed in 36 (22.1%) and 28 (19.6%) patients in each cuffed and uncuffed ETT groups. After adjusting for known RAE risk factors, no difference was observed in RAEs or respiratory interventions after extubation between both groups (odds ratio, 1.14; 95% confidence interval: 0.64, 2.06).</p><p><strong>Conclusion: </strong>In pediatric patients with airway hypersensitivity, the use of cuffed ETTs did not increase the occurrence of RAEs or respiratory interventions after extubation.</p>\",\"PeriodicalId\":14997,\"journal\":{\"name\":\"Journal of Anesthesia\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":2.8000,\"publicationDate\":\"2024-10-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Anesthesia\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s00540-024-03423-4\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ANESTHESIOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Anesthesia","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00540-024-03423-4","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ANESTHESIOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:气管导管(ETT)配置(带袖带或不带袖带)是否会影响高危患者呼吸道不良事件(RAE)的发生在很大程度上仍是未知数。我们研究了带袖带的 ETT 对气道过敏的儿科患者拔管后发生 RAE 的影响:方法:年龄为 5 岁的儿童:结果:163 名患者使用了带袖带 ETT,143 名患者使用了无袖带 ETT。除了上气道手术的频率和术中液体平衡外,两组患者的背景特征无明显差异。在拔管后出现 RAE 的患者中,带袖带 ETT 组有 36 人(22.1%),无袖带 ETT 组有 28 人(19.6%)。在对已知的 RAE 风险因素进行调整后,两组患者在拔管后发生 RAE 或进行呼吸干预的情况没有差异(几率比 1.14;95% 置信区间:0.64, 2.06):结论:在气道过敏的儿科患者中,使用带袖带的 ETT 不会增加 RAE 的发生率或拔管后的呼吸干预。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Effect of use of cuffed endotracheal tubes on the occurrence of postoperative extubation-related respiratory adverse events in pediatric patients with airway hypersensitivity: a retrospective cohort study.

Purpose: Whether endotracheal tube (ETT) configuration (cuffed or uncuffed) influences the occurrence of respiratory adverse events (RAEs) in patients at risk remains largely unknown. We investigated the effects of cuffed ETTs on RAE occurrence after extubation in pediatric patients with airway hypersensitivity.

Methods: Children aged < 8 years with increased airway hypersensitivity (defined as upper airway symptoms, recent upper respiratory infection within 2 weeks, or a history of asthma) who underwent general endotracheal anesthesia with inhaled agents between January 2021 and December 2022 were included. We retrospectively examined the patients' background and intraoperative anesthesia conditions by comparing the cuffed and uncuffed ETT groups. Multiple logistic regression analysis was performed to estimate the association between ETT configuration (cuffed vs. uncuffed) and the occurrence of RAEs or respiratory interventions (laryngospasm, peripheral capillary oxygen saturation < 92%, oxygen supplementation, epinephrine inhalation, or reintubation) after extubation.

Results: Cuffed ETTs were used in 163 patients and uncuffed ETTs in 143 patients. Apart from the frequency of upper airway surgery and intraoperative fluid balance, no significant differences in background characteristics were observed between the groups. RAEs after extubation were observed in 36 (22.1%) and 28 (19.6%) patients in each cuffed and uncuffed ETT groups. After adjusting for known RAE risk factors, no difference was observed in RAEs or respiratory interventions after extubation between both groups (odds ratio, 1.14; 95% confidence interval: 0.64, 2.06).

Conclusion: In pediatric patients with airway hypersensitivity, the use of cuffed ETTs did not increase the occurrence of RAEs or respiratory interventions after extubation.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Anesthesia
Journal of Anesthesia 医学-麻醉学
CiteScore
5.30
自引率
7.10%
发文量
112
审稿时长
3-8 weeks
期刊介绍: The Journal of Anesthesia is the official journal of the Japanese Society of Anesthesiologists. This journal publishes original articles, review articles, special articles, clinical reports, short communications, letters to the editor, and book and multimedia reviews. The editors welcome the submission of manuscripts devoted to anesthesia and related topics from any country of the world. Membership in the Society is not a prerequisite. The Journal of Anesthesia (JA) welcomes case reports that show unique cases in perioperative medicine, intensive care, emergency medicine, and pain management.
期刊最新文献
Correction: Decrease of the peak heights of EEG bicoherence indicated insufficiency of analgesia during surgery under general anesthesia. Advantages of neuraxial anesthesia for cesarean delivery. McGRATH MAC size 1 vs. 2 blades: infant intubation time. Radial artery catheterization using a novel T-type ultrasound probe: a single-center randomized study. Vasopressors against post-spinal anesthesia hypotension.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1