{"title":"使用化学传感器对巧克力釉的香气发展进行技术监测","authors":"T. A. Kuchmenko, R. P. Lisitskaya","doi":"10.1134/S1061934824701089","DOIUrl":null,"url":null,"abstract":"<p>The study demonstrates the potential for monitoring the dynamics of chocolate glaze aroma formation during conching using an artificial olfactory system based on an “electronic nose” with polymer- modified piezoelectric gas sensors. The samples were collected from an actual production environment, and mandatory quality control of their standard properties was conducted throughout the chocolate glaze conching process. The digitization and objective monitoring of the aroma development and maturation process were performed using a data matrix (recorded and calculated signals) from a piezoelectric sensor array. The sensor array, the responses of which correlate with specific physicochemical quality indicators of both semifinished products and final goods, was optimized beforehand. Correlations between the results of sensorometric analysis and the physicochemical quality indicators of confectionery glaze were revealed. Informative sensors were selected, with responses enabling the rapid assessment of standard characteristics, such as moisture content (based on the crown ether sensor with a Pearson correlation coefficient of <i>R</i> = 0.91) and acidity (based on the Tween-40 sensor with a Pearson correlation coefficient of <i>R</i> = 0.90–0.91). The most valuable information comes from monitoring the decrease in the amount of nonvolatile compounds, particularly in the total sugar content during conching, using signals from the Triton X-100 sensor (with a Pearson correlation coefficient of <i>R</i> = 0.89). As a criterion for the reproducibility of the qualitative and quantitative composition, we proposed a new digital characteristic of aroma—a set of binary sensitivity parameters from the “electronic nose” sensors—and developed a novel chemometric method for processing data sets for the test samples. The study demonstrates a potential for integrating an “electronic nose” into production for technological control, ensuring compliance with and optimization of recipes, and monitoring the conching process of chocolate glaze based on physicochemical indicators and digital characterization of the most unstable property—aroma. This approach allows for objective and reproducible quality assessment of confectionery products.</p>","PeriodicalId":606,"journal":{"name":"Journal of Analytical Chemistry","volume":null,"pages":null},"PeriodicalIF":1.0000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Using Chemical Sensors for Technological Monitoring of Aroma Development in Chocolate Glaze\",\"authors\":\"T. A. Kuchmenko, R. P. Lisitskaya\",\"doi\":\"10.1134/S1061934824701089\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>The study demonstrates the potential for monitoring the dynamics of chocolate glaze aroma formation during conching using an artificial olfactory system based on an “electronic nose” with polymer- modified piezoelectric gas sensors. The samples were collected from an actual production environment, and mandatory quality control of their standard properties was conducted throughout the chocolate glaze conching process. The digitization and objective monitoring of the aroma development and maturation process were performed using a data matrix (recorded and calculated signals) from a piezoelectric sensor array. The sensor array, the responses of which correlate with specific physicochemical quality indicators of both semifinished products and final goods, was optimized beforehand. Correlations between the results of sensorometric analysis and the physicochemical quality indicators of confectionery glaze were revealed. Informative sensors were selected, with responses enabling the rapid assessment of standard characteristics, such as moisture content (based on the crown ether sensor with a Pearson correlation coefficient of <i>R</i> = 0.91) and acidity (based on the Tween-40 sensor with a Pearson correlation coefficient of <i>R</i> = 0.90–0.91). The most valuable information comes from monitoring the decrease in the amount of nonvolatile compounds, particularly in the total sugar content during conching, using signals from the Triton X-100 sensor (with a Pearson correlation coefficient of <i>R</i> = 0.89). As a criterion for the reproducibility of the qualitative and quantitative composition, we proposed a new digital characteristic of aroma—a set of binary sensitivity parameters from the “electronic nose” sensors—and developed a novel chemometric method for processing data sets for the test samples. The study demonstrates a potential for integrating an “electronic nose” into production for technological control, ensuring compliance with and optimization of recipes, and monitoring the conching process of chocolate glaze based on physicochemical indicators and digital characterization of the most unstable property—aroma. This approach allows for objective and reproducible quality assessment of confectionery products.</p>\",\"PeriodicalId\":606,\"journal\":{\"name\":\"Journal of Analytical Chemistry\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.0000,\"publicationDate\":\"2024-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Analytical Chemistry\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://link.springer.com/article/10.1134/S1061934824701089\",\"RegionNum\":4,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Analytical Chemistry","FirstCategoryId":"92","ListUrlMain":"https://link.springer.com/article/10.1134/S1061934824701089","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0
摘要
这项研究表明,利用基于 "电子鼻 "的人工嗅觉系统和聚合物改性压电气体传感器,可以监测巧克力釉在凝结过程中香气形成的动态。样品从实际生产环境中采集,并在整个巧克力釉凝结过程中对其标准特性进行强制性质量控制。利用压电传感器阵列的数据矩阵(记录和计算信号)对香气的发展和成熟过程进行数字化和客观监测。传感器阵列的响应与半成品和最终产品的特定理化质量指标相关,并事先进行了优化。传感器测量分析结果与糖果釉料理化质量指标之间的相关性得到了揭示。选定的传感器信息丰富,能快速评估标准特性,如水分含量(基于冠醚传感器,皮尔逊相关系数为 R = 0.91)和酸度(基于吐温-40 传感器,皮尔逊相关系数为 R = 0.90-0.91)。最有价值的信息来自于利用 Triton X-100 传感器(皮尔逊相关系数为 R = 0.89)监测非挥发性化合物数量的减少,特别是在腌制过程中总糖含量的减少。作为定性和定量成分重现性的标准,我们提出了一种新的香气数字特征--"电子鼻 "传感器的一组二进制灵敏度参数,并开发了一种新的化学计量学方法来处理测试样品的数据集。这项研究展示了将 "电子鼻 "集成到生产中进行技术控制的潜力,确保符合和优化配方,并根据理化指标和最不稳定特性--香气的数字特征监测巧克力釉的凝结过程。这种方法可以对糖果产品进行客观和可重复的质量评估。
Using Chemical Sensors for Technological Monitoring of Aroma Development in Chocolate Glaze
The study demonstrates the potential for monitoring the dynamics of chocolate glaze aroma formation during conching using an artificial olfactory system based on an “electronic nose” with polymer- modified piezoelectric gas sensors. The samples were collected from an actual production environment, and mandatory quality control of their standard properties was conducted throughout the chocolate glaze conching process. The digitization and objective monitoring of the aroma development and maturation process were performed using a data matrix (recorded and calculated signals) from a piezoelectric sensor array. The sensor array, the responses of which correlate with specific physicochemical quality indicators of both semifinished products and final goods, was optimized beforehand. Correlations between the results of sensorometric analysis and the physicochemical quality indicators of confectionery glaze were revealed. Informative sensors were selected, with responses enabling the rapid assessment of standard characteristics, such as moisture content (based on the crown ether sensor with a Pearson correlation coefficient of R = 0.91) and acidity (based on the Tween-40 sensor with a Pearson correlation coefficient of R = 0.90–0.91). The most valuable information comes from monitoring the decrease in the amount of nonvolatile compounds, particularly in the total sugar content during conching, using signals from the Triton X-100 sensor (with a Pearson correlation coefficient of R = 0.89). As a criterion for the reproducibility of the qualitative and quantitative composition, we proposed a new digital characteristic of aroma—a set of binary sensitivity parameters from the “electronic nose” sensors—and developed a novel chemometric method for processing data sets for the test samples. The study demonstrates a potential for integrating an “electronic nose” into production for technological control, ensuring compliance with and optimization of recipes, and monitoring the conching process of chocolate glaze based on physicochemical indicators and digital characterization of the most unstable property—aroma. This approach allows for objective and reproducible quality assessment of confectionery products.
期刊介绍:
The Journal of Analytical Chemistry is an international peer reviewed journal that covers theoretical and applied aspects of analytical chemistry; it informs the reader about new achievements in analytical methods, instruments and reagents. Ample space is devoted to problems arising in the analysis of vital media such as water and air. Consideration is given to the detection and determination of metal ions, anions, and various organic substances. The journal welcomes manuscripts from all countries in the English or Russian language.