用于踝关节导航的智能手机直觉(SPAN):可靠性和位置暴露时间的影响。

IF 1.1 4区 心理学 Q4 NEUROSCIENCES Journal of Motor Behavior Pub Date : 2024-11-03 DOI:10.1080/00222895.2024.2416231
Xiaojian Shi, Charlotte Ganderton, Roger Adams, Jia Han, Doa El-Ansary, Oren Tirosh
{"title":"用于踝关节导航的智能手机直觉(SPAN):可靠性和位置暴露时间的影响。","authors":"Xiaojian Shi, Charlotte Ganderton, Roger Adams, Jia Han, Doa El-Ansary, Oren Tirosh","doi":"10.1080/00222895.2024.2416231","DOIUrl":null,"url":null,"abstract":"<p><p>This study investigated ankle discriminative acuity and performance and measurement consistency for tests undertaken with different joint position exposure times (PETs). Twenty-four participants were tested using a novel Smartphone Proprioception for Ankle Navigation (SPAN) under four PETs, i.e., 0.25s, 0.5s, 0.75s and 1s, delivered in a random sequence, and then re-tested within one week. The results indicated a PET main effect (<i>F</i> = 10.12, <i>p</i> = 0.004, partial ƞ2 = 0.14), and limb preference main effect (<i>F</i> = 5.39, <i>p</i> = 0.03, partial ƞ2 = 0.19), without significant interactions (<i>p</i> > 0.05). Ankle proprioception improved with prolonged PET, with the non-dominant side outperforming the dominant side. A PET of 0.25s showed good to excellent reliability, with intraclass correlation coefficients (ICCs) of 0.897 (95%CI: 0.761, 0.955) and 0.885 (95%CI: 0.736, 0.951), with standard errors of measurements (SEM) between 0.030 and 0.035, and minimum detectable change at 90% (MDC<sub>90</sub>) between 0.070 and 0.082, compared to poor to moderate reliability at the other three longer PETs (ICCs =0.352-0.736). The findings suggested the prolongation of PET can improve ankle proprioceptive performance but can amplify the inter-occasion variability, likely due to increased cognitive analysis with longer stimulus sampling. SPAN may thus be a cost-effective and accessible apparatus for clinical practice.</p>","PeriodicalId":50125,"journal":{"name":"Journal of Motor Behavior","volume":null,"pages":null},"PeriodicalIF":1.1000,"publicationDate":"2024-11-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Smartphone Proprioception for Ankle Navigation (SPAN): Reliability and Effect of Position Exposure Time.\",\"authors\":\"Xiaojian Shi, Charlotte Ganderton, Roger Adams, Jia Han, Doa El-Ansary, Oren Tirosh\",\"doi\":\"10.1080/00222895.2024.2416231\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>This study investigated ankle discriminative acuity and performance and measurement consistency for tests undertaken with different joint position exposure times (PETs). Twenty-four participants were tested using a novel Smartphone Proprioception for Ankle Navigation (SPAN) under four PETs, i.e., 0.25s, 0.5s, 0.75s and 1s, delivered in a random sequence, and then re-tested within one week. The results indicated a PET main effect (<i>F</i> = 10.12, <i>p</i> = 0.004, partial ƞ2 = 0.14), and limb preference main effect (<i>F</i> = 5.39, <i>p</i> = 0.03, partial ƞ2 = 0.19), without significant interactions (<i>p</i> > 0.05). Ankle proprioception improved with prolonged PET, with the non-dominant side outperforming the dominant side. A PET of 0.25s showed good to excellent reliability, with intraclass correlation coefficients (ICCs) of 0.897 (95%CI: 0.761, 0.955) and 0.885 (95%CI: 0.736, 0.951), with standard errors of measurements (SEM) between 0.030 and 0.035, and minimum detectable change at 90% (MDC<sub>90</sub>) between 0.070 and 0.082, compared to poor to moderate reliability at the other three longer PETs (ICCs =0.352-0.736). The findings suggested the prolongation of PET can improve ankle proprioceptive performance but can amplify the inter-occasion variability, likely due to increased cognitive analysis with longer stimulus sampling. SPAN may thus be a cost-effective and accessible apparatus for clinical practice.</p>\",\"PeriodicalId\":50125,\"journal\":{\"name\":\"Journal of Motor Behavior\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2024-11-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Motor Behavior\",\"FirstCategoryId\":\"102\",\"ListUrlMain\":\"https://doi.org/10.1080/00222895.2024.2416231\",\"RegionNum\":4,\"RegionCategory\":\"心理学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"NEUROSCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Motor Behavior","FirstCategoryId":"102","ListUrlMain":"https://doi.org/10.1080/00222895.2024.2416231","RegionNum":4,"RegionCategory":"心理学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"NEUROSCIENCES","Score":null,"Total":0}
引用次数: 0

摘要

本研究调查了在不同关节位置暴露时间(PET)下进行测试时踝关节的辨别敏锐度、性能和测量一致性。24 名参与者使用新型智能手机踝关节感知导航(SPAN)进行了测试,测试采用四种 PET,即 0.25 秒、0.5 秒、0.75 秒和 1 秒,以随机顺序进行,然后在一周内进行复测。结果显示 PET 主效应(F = 10.12,p = 0.004,部分ƞ2 = 0.14)和肢体偏好主效应(F = 5.39,p = 0.03,部分ƞ2 = 0.19),没有显著的交互作用(p > 0.05)。随着 PET 时间的延长,踝关节本体感觉有所改善,非优势侧优于优势侧。0.25 秒的 PET 显示出良好至卓越的可靠性,类内相关系数 (ICC) 分别为 0.897(95%CI:0.761,0.955)和 0.885(95%CI:0.736,0.951),测量标准误差 (SEM) 介于 0.030 和 0.035 之间,测量误差 (SEM) 介于 0.030 和 0.035 之间。相比之下,其他三个较长 PET 的可靠性为差到中等(ICC =0.352-0.736)。研究结果表明,延长 PET 时间可以提高踝关节本体感觉性能,但会扩大事件间的变异性,这可能是由于刺激取样时间延长导致认知分析增加所致。因此,SPAN 可能是临床实践中一种具有成本效益且易于使用的仪器。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Smartphone Proprioception for Ankle Navigation (SPAN): Reliability and Effect of Position Exposure Time.

This study investigated ankle discriminative acuity and performance and measurement consistency for tests undertaken with different joint position exposure times (PETs). Twenty-four participants were tested using a novel Smartphone Proprioception for Ankle Navigation (SPAN) under four PETs, i.e., 0.25s, 0.5s, 0.75s and 1s, delivered in a random sequence, and then re-tested within one week. The results indicated a PET main effect (F = 10.12, p = 0.004, partial ƞ2 = 0.14), and limb preference main effect (F = 5.39, p = 0.03, partial ƞ2 = 0.19), without significant interactions (p > 0.05). Ankle proprioception improved with prolonged PET, with the non-dominant side outperforming the dominant side. A PET of 0.25s showed good to excellent reliability, with intraclass correlation coefficients (ICCs) of 0.897 (95%CI: 0.761, 0.955) and 0.885 (95%CI: 0.736, 0.951), with standard errors of measurements (SEM) between 0.030 and 0.035, and minimum detectable change at 90% (MDC90) between 0.070 and 0.082, compared to poor to moderate reliability at the other three longer PETs (ICCs =0.352-0.736). The findings suggested the prolongation of PET can improve ankle proprioceptive performance but can amplify the inter-occasion variability, likely due to increased cognitive analysis with longer stimulus sampling. SPAN may thus be a cost-effective and accessible apparatus for clinical practice.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Motor Behavior
Journal of Motor Behavior 医学-神经科学
CiteScore
3.10
自引率
0.00%
发文量
39
审稿时长
>12 weeks
期刊介绍: The Journal of Motor Behavior, a multidisciplinary journal of movement neuroscience, publishes articles that contribute to a basic understanding of motor control. Articles from different disciplinary perspectives and levels of analysis are encouraged, including neurophysiological, biomechanical, electrophysiological, psychological, mathematical and physical, and clinical approaches. Applied studies are acceptable only to the extent that they provide a significant contribution to a basic issue in motor control. Of special interest to the journal are those articles that attempt to bridge insights from different disciplinary perspectives to infer processes underlying motor control. Those approaches may embrace postural, locomotive, and manipulative aspects of motor functions, as well as coordination of speech articulators and eye movements. Articles dealing with analytical techniques and mathematical modeling are welcome.
期刊最新文献
Factors Influencing Gait Performance: Comfortable Linear Gait and Complex Gait in School-Aged Children in a Dual-Task Model. Smartphone Proprioception for Ankle Navigation (SPAN): Reliability and Effect of Position Exposure Time. Kinematic Analysis of Reaching Tasks at Different Execution Speeds in Children with Neonatal Brachial Plexus Palsy. The Effects of Constraints on the Variability of Throwing Patterns in Young Children. Effects of Constraining Postural Sway During Upper-Limb Precision Aiming Task Practice in Individuals with Stroke.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1