Xiaojian Shi, Charlotte Ganderton, Roger Adams, Jia Han, Doa El-Ansary, Oren Tirosh
{"title":"用于踝关节导航的智能手机直觉(SPAN):可靠性和位置暴露时间的影响。","authors":"Xiaojian Shi, Charlotte Ganderton, Roger Adams, Jia Han, Doa El-Ansary, Oren Tirosh","doi":"10.1080/00222895.2024.2416231","DOIUrl":null,"url":null,"abstract":"<p><p>This study investigated ankle discriminative acuity and performance and measurement consistency for tests undertaken with different joint position exposure times (PETs). Twenty-four participants were tested using a novel Smartphone Proprioception for Ankle Navigation (SPAN) under four PETs, i.e., 0.25s, 0.5s, 0.75s and 1s, delivered in a random sequence, and then re-tested within one week. The results indicated a PET main effect (<i>F</i> = 10.12, <i>p</i> = 0.004, partial ƞ2 = 0.14), and limb preference main effect (<i>F</i> = 5.39, <i>p</i> = 0.03, partial ƞ2 = 0.19), without significant interactions (<i>p</i> > 0.05). Ankle proprioception improved with prolonged PET, with the non-dominant side outperforming the dominant side. A PET of 0.25s showed good to excellent reliability, with intraclass correlation coefficients (ICCs) of 0.897 (95%CI: 0.761, 0.955) and 0.885 (95%CI: 0.736, 0.951), with standard errors of measurements (SEM) between 0.030 and 0.035, and minimum detectable change at 90% (MDC<sub>90</sub>) between 0.070 and 0.082, compared to poor to moderate reliability at the other three longer PETs (ICCs =0.352-0.736). The findings suggested the prolongation of PET can improve ankle proprioceptive performance but can amplify the inter-occasion variability, likely due to increased cognitive analysis with longer stimulus sampling. SPAN may thus be a cost-effective and accessible apparatus for clinical practice.</p>","PeriodicalId":50125,"journal":{"name":"Journal of Motor Behavior","volume":null,"pages":null},"PeriodicalIF":1.1000,"publicationDate":"2024-11-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Smartphone Proprioception for Ankle Navigation (SPAN): Reliability and Effect of Position Exposure Time.\",\"authors\":\"Xiaojian Shi, Charlotte Ganderton, Roger Adams, Jia Han, Doa El-Ansary, Oren Tirosh\",\"doi\":\"10.1080/00222895.2024.2416231\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>This study investigated ankle discriminative acuity and performance and measurement consistency for tests undertaken with different joint position exposure times (PETs). Twenty-four participants were tested using a novel Smartphone Proprioception for Ankle Navigation (SPAN) under four PETs, i.e., 0.25s, 0.5s, 0.75s and 1s, delivered in a random sequence, and then re-tested within one week. The results indicated a PET main effect (<i>F</i> = 10.12, <i>p</i> = 0.004, partial ƞ2 = 0.14), and limb preference main effect (<i>F</i> = 5.39, <i>p</i> = 0.03, partial ƞ2 = 0.19), without significant interactions (<i>p</i> > 0.05). Ankle proprioception improved with prolonged PET, with the non-dominant side outperforming the dominant side. A PET of 0.25s showed good to excellent reliability, with intraclass correlation coefficients (ICCs) of 0.897 (95%CI: 0.761, 0.955) and 0.885 (95%CI: 0.736, 0.951), with standard errors of measurements (SEM) between 0.030 and 0.035, and minimum detectable change at 90% (MDC<sub>90</sub>) between 0.070 and 0.082, compared to poor to moderate reliability at the other three longer PETs (ICCs =0.352-0.736). The findings suggested the prolongation of PET can improve ankle proprioceptive performance but can amplify the inter-occasion variability, likely due to increased cognitive analysis with longer stimulus sampling. SPAN may thus be a cost-effective and accessible apparatus for clinical practice.</p>\",\"PeriodicalId\":50125,\"journal\":{\"name\":\"Journal of Motor Behavior\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2024-11-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Motor Behavior\",\"FirstCategoryId\":\"102\",\"ListUrlMain\":\"https://doi.org/10.1080/00222895.2024.2416231\",\"RegionNum\":4,\"RegionCategory\":\"心理学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"NEUROSCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Motor Behavior","FirstCategoryId":"102","ListUrlMain":"https://doi.org/10.1080/00222895.2024.2416231","RegionNum":4,"RegionCategory":"心理学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"NEUROSCIENCES","Score":null,"Total":0}
Smartphone Proprioception for Ankle Navigation (SPAN): Reliability and Effect of Position Exposure Time.
This study investigated ankle discriminative acuity and performance and measurement consistency for tests undertaken with different joint position exposure times (PETs). Twenty-four participants were tested using a novel Smartphone Proprioception for Ankle Navigation (SPAN) under four PETs, i.e., 0.25s, 0.5s, 0.75s and 1s, delivered in a random sequence, and then re-tested within one week. The results indicated a PET main effect (F = 10.12, p = 0.004, partial ƞ2 = 0.14), and limb preference main effect (F = 5.39, p = 0.03, partial ƞ2 = 0.19), without significant interactions (p > 0.05). Ankle proprioception improved with prolonged PET, with the non-dominant side outperforming the dominant side. A PET of 0.25s showed good to excellent reliability, with intraclass correlation coefficients (ICCs) of 0.897 (95%CI: 0.761, 0.955) and 0.885 (95%CI: 0.736, 0.951), with standard errors of measurements (SEM) between 0.030 and 0.035, and minimum detectable change at 90% (MDC90) between 0.070 and 0.082, compared to poor to moderate reliability at the other three longer PETs (ICCs =0.352-0.736). The findings suggested the prolongation of PET can improve ankle proprioceptive performance but can amplify the inter-occasion variability, likely due to increased cognitive analysis with longer stimulus sampling. SPAN may thus be a cost-effective and accessible apparatus for clinical practice.
期刊介绍:
The Journal of Motor Behavior, a multidisciplinary journal of movement neuroscience, publishes articles that contribute to a basic understanding of motor control. Articles from different disciplinary perspectives and levels of analysis are encouraged, including neurophysiological, biomechanical, electrophysiological, psychological, mathematical and physical, and clinical approaches. Applied studies are acceptable only to the extent that they provide a significant contribution to a basic issue in motor control. Of special interest to the journal are those articles that attempt to bridge insights from different disciplinary perspectives to infer processes underlying motor control. Those approaches may embrace postural, locomotive, and manipulative aspects of motor functions, as well as coordination of speech articulators and eye movements. Articles dealing with analytical techniques and mathematical modeling are welcome.