在使用金属块增量的受约束髁状全膝关节置换术中,胫骨组件的非对称设计是否优于对称设计?

IF 4.6 Q2 MATERIALS SCIENCE, BIOMATERIALS ACS Applied Bio Materials Pub Date : 2024-11-04 DOI:10.1186/s42836-024-00277-9
Ryosuke Kabu, Hidetoshi Tsushima, Yukio Akasaki, Shinya Kawahara, Satoshi Hamai, Yasuharu Nakashima
{"title":"在使用金属块增量的受约束髁状全膝关节置换术中,胫骨组件的非对称设计是否优于对称设计?","authors":"Ryosuke Kabu, Hidetoshi Tsushima, Yukio Akasaki, Shinya Kawahara, Satoshi Hamai, Yasuharu Nakashima","doi":"10.1186/s42836-024-00277-9","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>In total knee arthroplasty (TKA), asymmetric tibial components have been developed alongside symmetric tibial components to enhance bony coverage at the tibia. In primary TKA and revision TKA for patients with significant bone defects, augmentation is employed to fill the bone defect. However, there have been no reports on bony coverage of the tibial component of the revision system in the cases of bone defects. Therefore, we simulated bone defects using CT and compared the bony coverage of asymmetric and symmetric tibial components in the revision TKA system.</p><p><strong>Methods: </strong>This study included 45 patients (50 knees involved) with medial osteoarthritis. Preoperative CT scans were used to simulate placement using ZedKnee. Three models were evaluated: Persona Revision PCCK (Zimmer) for the asymmetric component, NexGen LCCK (Zimmer) for the symmetric component, and the ATTUNE revision system (Depuy-Synthes). A 130-mm stem extension was utilized. Augmentations of each thickness were placed to simulate bone defects of 5, 10, and 15 mm. The coverage, overhang, and underhang rates were measured for each slice and compared among the models.</p><p><strong>Results: </strong>In terms of coverage, the rate was greater for PCCK at 0 mm, and only ATTUNE exhibited a significantly lower coverage at 5 and 10 mm. There was no significant difference in coverage at 15 mm. At 0 mm, PCCK demonstrated less posterior underhangs. At 5 and 10 mm, PCCK showed less anterior overhang but more anterior underhang. At 15 mm, PCCK had a less anterior overhang, with an overhang in the posterior region but less underhang. When overhang and underhang were combined and compared, the asymmetric component generally yielded superior results.</p><p><strong>Conclusion: </strong>In the cases of bone defects, asymmetric components demonstrated reduced anterior overhang and decreased posterior underhang, resulting in greater bone coverage. This may contribute to improved long-term outcomes in the revision TKA system.</p>","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":null,"pages":null},"PeriodicalIF":4.6000,"publicationDate":"2024-11-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11533327/pdf/","citationCount":"0","resultStr":"{\"title\":\"Are asymmetric designs of tibial components superior to their symmetric counterparts for constrained condylar total knee arthroplasty using metal block augmentation?\",\"authors\":\"Ryosuke Kabu, Hidetoshi Tsushima, Yukio Akasaki, Shinya Kawahara, Satoshi Hamai, Yasuharu Nakashima\",\"doi\":\"10.1186/s42836-024-00277-9\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>In total knee arthroplasty (TKA), asymmetric tibial components have been developed alongside symmetric tibial components to enhance bony coverage at the tibia. In primary TKA and revision TKA for patients with significant bone defects, augmentation is employed to fill the bone defect. However, there have been no reports on bony coverage of the tibial component of the revision system in the cases of bone defects. Therefore, we simulated bone defects using CT and compared the bony coverage of asymmetric and symmetric tibial components in the revision TKA system.</p><p><strong>Methods: </strong>This study included 45 patients (50 knees involved) with medial osteoarthritis. Preoperative CT scans were used to simulate placement using ZedKnee. Three models were evaluated: Persona Revision PCCK (Zimmer) for the asymmetric component, NexGen LCCK (Zimmer) for the symmetric component, and the ATTUNE revision system (Depuy-Synthes). A 130-mm stem extension was utilized. Augmentations of each thickness were placed to simulate bone defects of 5, 10, and 15 mm. The coverage, overhang, and underhang rates were measured for each slice and compared among the models.</p><p><strong>Results: </strong>In terms of coverage, the rate was greater for PCCK at 0 mm, and only ATTUNE exhibited a significantly lower coverage at 5 and 10 mm. There was no significant difference in coverage at 15 mm. At 0 mm, PCCK demonstrated less posterior underhangs. At 5 and 10 mm, PCCK showed less anterior overhang but more anterior underhang. At 15 mm, PCCK had a less anterior overhang, with an overhang in the posterior region but less underhang. When overhang and underhang were combined and compared, the asymmetric component generally yielded superior results.</p><p><strong>Conclusion: </strong>In the cases of bone defects, asymmetric components demonstrated reduced anterior overhang and decreased posterior underhang, resulting in greater bone coverage. This may contribute to improved long-term outcomes in the revision TKA system.</p>\",\"PeriodicalId\":2,\"journal\":{\"name\":\"ACS Applied Bio Materials\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":4.6000,\"publicationDate\":\"2024-11-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11533327/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACS Applied Bio Materials\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1186/s42836-024-00277-9\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"MATERIALS SCIENCE, BIOMATERIALS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s42836-024-00277-9","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
引用次数: 0

摘要

目的:在全膝关节置换术(TKA)中,非对称胫骨组件与对称胫骨组件同时开发,以增强胫骨的骨覆盖。在初次全膝关节置换术(TKA)和翻修全膝关节置换术(TKA)中,对于有明显骨缺损的患者,会采用增量来填补骨缺损。然而,目前还没有关于翻修系统胫骨组件在骨缺损情况下的骨覆盖的报道。因此,我们使用 CT 模拟了骨缺损,并比较了翻修 TKA 系统中非对称和对称胫骨组件的骨覆盖情况:这项研究包括 45 名内侧骨关节炎患者(涉及 50 个膝关节)。术前 CT 扫描用于使用 ZedKnee 模拟放置。对三种模型进行了评估:用于非对称组件的Persona Revision PCCK(Zimmer)、用于对称组件的NexGen LCCK(Zimmer)和ATTUNE翻修系统(Depuy-Synthes)。使用了130毫米的骨干延伸。每种厚度的植入物分别用于模拟5、10和15毫米的骨缺损。测量了每个切片的覆盖率、上悬率和下悬率,并对不同模型进行了比较:结果:就覆盖率而言,PCCK 在 0 毫米处的覆盖率更高,只有 ATTUNE 在 5 毫米和 10 毫米处的覆盖率明显较低。15 毫米处的覆盖率没有明显差异。在 0 毫米时,PCCK 的后下悬较少。在 5 毫米和 10 毫米时,PCCK 显示出较少的前悬,但较多的前下悬。15 毫米时,PCCK 的前悬较少,后悬较多,但下悬较少。如果将前悬和后悬结合起来进行比较,不对称组件的效果通常更好:结论:在骨缺损的病例中,非对称组件减少了前悬,减少了后悬,从而获得了更大的骨覆盖。这可能有助于改善翻修 TKA 系统的长期效果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Are asymmetric designs of tibial components superior to their symmetric counterparts for constrained condylar total knee arthroplasty using metal block augmentation?

Purpose: In total knee arthroplasty (TKA), asymmetric tibial components have been developed alongside symmetric tibial components to enhance bony coverage at the tibia. In primary TKA and revision TKA for patients with significant bone defects, augmentation is employed to fill the bone defect. However, there have been no reports on bony coverage of the tibial component of the revision system in the cases of bone defects. Therefore, we simulated bone defects using CT and compared the bony coverage of asymmetric and symmetric tibial components in the revision TKA system.

Methods: This study included 45 patients (50 knees involved) with medial osteoarthritis. Preoperative CT scans were used to simulate placement using ZedKnee. Three models were evaluated: Persona Revision PCCK (Zimmer) for the asymmetric component, NexGen LCCK (Zimmer) for the symmetric component, and the ATTUNE revision system (Depuy-Synthes). A 130-mm stem extension was utilized. Augmentations of each thickness were placed to simulate bone defects of 5, 10, and 15 mm. The coverage, overhang, and underhang rates were measured for each slice and compared among the models.

Results: In terms of coverage, the rate was greater for PCCK at 0 mm, and only ATTUNE exhibited a significantly lower coverage at 5 and 10 mm. There was no significant difference in coverage at 15 mm. At 0 mm, PCCK demonstrated less posterior underhangs. At 5 and 10 mm, PCCK showed less anterior overhang but more anterior underhang. At 15 mm, PCCK had a less anterior overhang, with an overhang in the posterior region but less underhang. When overhang and underhang were combined and compared, the asymmetric component generally yielded superior results.

Conclusion: In the cases of bone defects, asymmetric components demonstrated reduced anterior overhang and decreased posterior underhang, resulting in greater bone coverage. This may contribute to improved long-term outcomes in the revision TKA system.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
ACS Applied Bio Materials
ACS Applied Bio Materials Chemistry-Chemistry (all)
CiteScore
9.40
自引率
2.10%
发文量
464
期刊最新文献
A Systematic Review of Sleep Disturbance in Idiopathic Intracranial Hypertension. Advancing Patient Education in Idiopathic Intracranial Hypertension: The Promise of Large Language Models. Anti-Myelin-Associated Glycoprotein Neuropathy: Recent Developments. Approach to Managing the Initial Presentation of Multiple Sclerosis: A Worldwide Practice Survey. Association Between LACE+ Index Risk Category and 90-Day Mortality After Stroke.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1