{"title":"视觉诱发反应的刺激诱导旋转饱和成像:试点研究","authors":"Milena Capiglioni, Roland Beisteiner, Pedro Lima Cardoso, Federico Turco, Baudouin Jin, Claus Kiefer, Simon Daniel Robinson, Andrea Federspiel, Siegfried Trattnig, Roland Wiest","doi":"10.1002/nbm.5280","DOIUrl":null,"url":null,"abstract":"<p><p>Spin-lock (SL) pulses have been proposed to directly detect neuronal activity otherwise inaccessible through standard functional magnetic resonance imaging. However, the practical limits of this technique remain unexplored. Key challenges in SL-based detection include ultra-weak signal variations, sensitivity to magnetic field inhomogeneities, and potential contamination from blood oxygen level-dependent effects, all of which hinder the reliable isolation of neuronal signals. This pilot study evaluates the performance of the stimulus-induced rotary saturation (SIRS) technique to map visual stimulation response in the human cortex. A rotary echo spin-lock (RESL) preparation followed by a 2D echo planar imaging readout was used to investigate 12 healthy subjects at rest and during continuous exposure to 8 Hz flickering light. The SL amplitude was fixed to the target neuroelectric oscillations at that frequency. The signal variance was used as contrast metric, and two alternative post-processing pipelines (regression-filtering-rectification and normalized subtraction) were statistically evaluated. Higher variance in the SL signal was detected in four of the 12 subjects. Although group-level analysis indicated activation in the occipital pole, analysis of variance revealed that this difference was not statistically significant, highlighting the need for comparable control measures and more robust preparations. Further optimization in sensitivity and robustness is required to noninvasively detect physiological neuroelectric activity in the human brain.</p>","PeriodicalId":19309,"journal":{"name":"NMR in Biomedicine","volume":" ","pages":"e5280"},"PeriodicalIF":2.7000,"publicationDate":"2024-11-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Stimulus-induced rotary saturation imaging of visually evoked response: A pilot study.\",\"authors\":\"Milena Capiglioni, Roland Beisteiner, Pedro Lima Cardoso, Federico Turco, Baudouin Jin, Claus Kiefer, Simon Daniel Robinson, Andrea Federspiel, Siegfried Trattnig, Roland Wiest\",\"doi\":\"10.1002/nbm.5280\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Spin-lock (SL) pulses have been proposed to directly detect neuronal activity otherwise inaccessible through standard functional magnetic resonance imaging. However, the practical limits of this technique remain unexplored. Key challenges in SL-based detection include ultra-weak signal variations, sensitivity to magnetic field inhomogeneities, and potential contamination from blood oxygen level-dependent effects, all of which hinder the reliable isolation of neuronal signals. This pilot study evaluates the performance of the stimulus-induced rotary saturation (SIRS) technique to map visual stimulation response in the human cortex. A rotary echo spin-lock (RESL) preparation followed by a 2D echo planar imaging readout was used to investigate 12 healthy subjects at rest and during continuous exposure to 8 Hz flickering light. The SL amplitude was fixed to the target neuroelectric oscillations at that frequency. The signal variance was used as contrast metric, and two alternative post-processing pipelines (regression-filtering-rectification and normalized subtraction) were statistically evaluated. Higher variance in the SL signal was detected in four of the 12 subjects. Although group-level analysis indicated activation in the occipital pole, analysis of variance revealed that this difference was not statistically significant, highlighting the need for comparable control measures and more robust preparations. Further optimization in sensitivity and robustness is required to noninvasively detect physiological neuroelectric activity in the human brain.</p>\",\"PeriodicalId\":19309,\"journal\":{\"name\":\"NMR in Biomedicine\",\"volume\":\" \",\"pages\":\"e5280\"},\"PeriodicalIF\":2.7000,\"publicationDate\":\"2024-11-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"NMR in Biomedicine\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1002/nbm.5280\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"BIOPHYSICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"NMR in Biomedicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/nbm.5280","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"BIOPHYSICS","Score":null,"Total":0}
引用次数: 0

摘要

有人提出用自旋锁定(SL)脉冲直接检测神经元活动,否则标准功能磁共振成像就无法检测到神经元活动。然而,这种技术的实际限制仍有待探索。基于锁相脉冲的检测所面临的主要挑战包括超弱信号变化、对磁场不均匀性的敏感性以及血氧水平相关效应的潜在污染,所有这些都阻碍了神经元信号的可靠分离。这项试验性研究评估了刺激诱导旋转饱和(SIRS)技术在绘制人体皮层视觉刺激反应图方面的性能。研究人员使用旋转回波自旋锁定(RESL)制备方法和二维回波平面成像读出方法,对 12 名健康受试者进行了静态和持续暴露于 8 赫兹闪烁光时的研究。SL振幅固定为该频率下的目标神经电振荡。使用信号方差作为对比度指标,并对两种可供选择的后处理管道(回归-过滤-校正和归一化减法)进行了统计评估。在 12 个受试者中,有 4 个受试者的 SL 信号方差较大。虽然组级分析表明枕极有激活现象,但方差分析显示这种差异在统计学上并不显著,这突出表明需要可比的控制措施和更稳健的制备方法。要想无创检测人脑中的生理神经电活动,还需要进一步优化灵敏度和稳健性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Stimulus-induced rotary saturation imaging of visually evoked response: A pilot study.

Spin-lock (SL) pulses have been proposed to directly detect neuronal activity otherwise inaccessible through standard functional magnetic resonance imaging. However, the practical limits of this technique remain unexplored. Key challenges in SL-based detection include ultra-weak signal variations, sensitivity to magnetic field inhomogeneities, and potential contamination from blood oxygen level-dependent effects, all of which hinder the reliable isolation of neuronal signals. This pilot study evaluates the performance of the stimulus-induced rotary saturation (SIRS) technique to map visual stimulation response in the human cortex. A rotary echo spin-lock (RESL) preparation followed by a 2D echo planar imaging readout was used to investigate 12 healthy subjects at rest and during continuous exposure to 8 Hz flickering light. The SL amplitude was fixed to the target neuroelectric oscillations at that frequency. The signal variance was used as contrast metric, and two alternative post-processing pipelines (regression-filtering-rectification and normalized subtraction) were statistically evaluated. Higher variance in the SL signal was detected in four of the 12 subjects. Although group-level analysis indicated activation in the occipital pole, analysis of variance revealed that this difference was not statistically significant, highlighting the need for comparable control measures and more robust preparations. Further optimization in sensitivity and robustness is required to noninvasively detect physiological neuroelectric activity in the human brain.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
NMR in Biomedicine
NMR in Biomedicine 医学-光谱学
CiteScore
6.00
自引率
10.30%
发文量
209
审稿时长
3-8 weeks
期刊介绍: NMR in Biomedicine is a journal devoted to the publication of original full-length papers, rapid communications and review articles describing the development of magnetic resonance spectroscopy or imaging methods or their use to investigate physiological, biochemical, biophysical or medical problems. Topics for submitted papers should be in one of the following general categories: (a) development of methods and instrumentation for MR of biological systems; (b) studies of normal or diseased organs, tissues or cells; (c) diagnosis or treatment of disease. Reports may cover work on patients or healthy human subjects, in vivo animal experiments, studies of isolated organs or cultured cells, analysis of tissue extracts, NMR theory, experimental techniques, or instrumentation.
期刊最新文献
The effect of fat model variation on muscle fat fraction quantification in a cross-sectional cohort. Improvement of MRS at ultra-high field using a wireless RF array. Very-long T2-weighted imaging of the non-lesional brain tissue in multiple sclerosis patients. Simultaneous whole-liver water T 1 and T 2 mapping with isotropic resolution during free-breathing. Automatic pipeline for segmentation of LV myocardium on quantitative MR T1 maps using deep learning model and computation of radial T1 and ECV values.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1