{"title":"太阳能吸收辐射冷却系统的热舒适约束非线性运行优化","authors":"Ahmed E. Elbakhshwan ,&nbsp;Muhammed A. Hassan ,&nbsp;Mahmoud A. Kassem ,&nbsp;Mohamad T. Araji","doi":"10.1016/j.enconman.2024.119204","DOIUrl":null,"url":null,"abstract":"<div><div>With the increasing demand for sustainable building solutions, especially under extreme weather conditions, there is a growing need for renewable-powered cooling systems that can minimize energy consumption and carbon emissions. Solar-absorption-radiant cooling systems offer a promising alternative to traditional air conditioning systems, but their effectiveness relies on efficient control strategies. This study investigates the optimal control of a solar-absorption-radiant cooling system for a single-story office building using non-linear programming (NLP) to minimize operating costs while maintaining thermal comfort. This is achieved by directly integrating the building model and thermal comfort calculations within the optimization procedure. By incorporating a solar collector, storage tank, assisting boiler, and absorption chiller, the system achieves a solar fraction of 0.8, minimizing daily operating costs to 2.11 USD and carbon emissions to ∼ 39.1 <span><math><mrow><mi>k</mi><msub><mi>g</mi><mrow><mi>C</mi><msub><mi>O</mi><mn>2</mn></msub></mrow></msub></mrow></math></span>. The system maintains an average PMV of 0.14, an operative temperature of 25.63 °C, and a coefficient of performance of 0.72. The study also explores the impact of varying thermal comfort constraints, ventilation rates, and inlet air temperatures on system performance. Stricter comfort constraints (PMV=-0.2 to 0.2) increase costs and emissions by 30.96 % and 37.5 % respectively, due to increased reliance on the natural gas boiler. Doubling the ventilation rate based on fresh outdoor air increases daily costs and emissions by 19 % and 22.6 % respectively. Conversely, utilizing a supplementary system to supply ventilation air at 25 °C significantly reduces costs and emissions by 26.2 % and 25.4 % respectively, and increases the solar fraction to 0.92. Compared to a conventional system powered solely by a natural gas boiler, the solar-powered system achieves substantial cost savings (45.9 %), reduced carbon emissions (52.5 %), and improved thermal comfort, highlighting the potential of this technology for sustainable building operations.</div></div>","PeriodicalId":11664,"journal":{"name":"Energy Conversion and Management","volume":null,"pages":null},"PeriodicalIF":9.9000,"publicationDate":"2024-11-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Thermal comfort-constrained nonlinear operational optimization of a solar-absorption-radiant cooling system\",\"authors\":\"Ahmed E. Elbakhshwan ,&nbsp;Muhammed A. Hassan ,&nbsp;Mahmoud A. Kassem ,&nbsp;Mohamad T. Araji\",\"doi\":\"10.1016/j.enconman.2024.119204\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>With the increasing demand for sustainable building solutions, especially under extreme weather conditions, there is a growing need for renewable-powered cooling systems that can minimize energy consumption and carbon emissions. Solar-absorption-radiant cooling systems offer a promising alternative to traditional air conditioning systems, but their effectiveness relies on efficient control strategies. This study investigates the optimal control of a solar-absorption-radiant cooling system for a single-story office building using non-linear programming (NLP) to minimize operating costs while maintaining thermal comfort. This is achieved by directly integrating the building model and thermal comfort calculations within the optimization procedure. By incorporating a solar collector, storage tank, assisting boiler, and absorption chiller, the system achieves a solar fraction of 0.8, minimizing daily operating costs to 2.11 USD and carbon emissions to ∼ 39.1 <span><math><mrow><mi>k</mi><msub><mi>g</mi><mrow><mi>C</mi><msub><mi>O</mi><mn>2</mn></msub></mrow></msub></mrow></math></span>. The system maintains an average PMV of 0.14, an operative temperature of 25.63 °C, and a coefficient of performance of 0.72. The study also explores the impact of varying thermal comfort constraints, ventilation rates, and inlet air temperatures on system performance. Stricter comfort constraints (PMV=-0.2 to 0.2) increase costs and emissions by 30.96 % and 37.5 % respectively, due to increased reliance on the natural gas boiler. Doubling the ventilation rate based on fresh outdoor air increases daily costs and emissions by 19 % and 22.6 % respectively. Conversely, utilizing a supplementary system to supply ventilation air at 25 °C significantly reduces costs and emissions by 26.2 % and 25.4 % respectively, and increases the solar fraction to 0.92. Compared to a conventional system powered solely by a natural gas boiler, the solar-powered system achieves substantial cost savings (45.9 %), reduced carbon emissions (52.5 %), and improved thermal comfort, highlighting the potential of this technology for sustainable building operations.</div></div>\",\"PeriodicalId\":11664,\"journal\":{\"name\":\"Energy Conversion and Management\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":9.9000,\"publicationDate\":\"2024-11-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Energy Conversion and Management\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0196890424011452\",\"RegionNum\":1,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ENERGY & FUELS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Energy Conversion and Management","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0196890424011452","RegionNum":1,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENERGY & FUELS","Score":null,"Total":0}
引用次数: 0

摘要

随着人们对可持续建筑解决方案的需求日益增长,尤其是在极端天气条件下,对可最大限度降低能耗和碳排放的可再生能源冷却系统的需求也越来越大。太阳能吸收辐射冷却系统为传统空调系统提供了一种前景广阔的替代方案,但其有效性有赖于高效的控制策略。本研究利用非线性编程(NLP)对单层办公楼的太阳能吸收辐射冷却系统进行优化控制,以在保持热舒适度的同时最大限度地降低运行成本。这是通过在优化程序中直接集成建筑模型和热舒适度计算来实现的。通过整合太阳能集热器、储水箱、辅助锅炉和吸收式冷水机组,该系统的太阳能利用率达到 0.8,将每日运营成本降至 2.11 美元,碳排放量降至 39.1 千克二氧化碳。该系统的平均 PMV 为 0.14,工作温度为 25.63 °C,性能系数为 0.72。研究还探讨了不同的热舒适度限制、通风率和进气温度对系统性能的影响。更严格的舒适度限制(PMV=-0.2 至 0.2)使成本和排放量分别增加了 30.96 % 和 37.5 %,原因是对天然气锅炉的依赖性增加。基于室外新鲜空气的通风率增加一倍,每天的成本和排放量分别增加 19% 和 22.6%。相反,利用辅助系统提供 25 ° C 的通风空气则可显著降低成本和排放量,分别降低 26.2 % 和 25.4 %,并将太阳能比例提高到 0.92。与仅由天然气锅炉提供动力的传统系统相比,太阳能供电系统节省了大量成本(45.9%),减少了碳排放(52.5%),并提高了热舒适度,凸显了该技术在可持续建筑运营方面的潜力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Thermal comfort-constrained nonlinear operational optimization of a solar-absorption-radiant cooling system
With the increasing demand for sustainable building solutions, especially under extreme weather conditions, there is a growing need for renewable-powered cooling systems that can minimize energy consumption and carbon emissions. Solar-absorption-radiant cooling systems offer a promising alternative to traditional air conditioning systems, but their effectiveness relies on efficient control strategies. This study investigates the optimal control of a solar-absorption-radiant cooling system for a single-story office building using non-linear programming (NLP) to minimize operating costs while maintaining thermal comfort. This is achieved by directly integrating the building model and thermal comfort calculations within the optimization procedure. By incorporating a solar collector, storage tank, assisting boiler, and absorption chiller, the system achieves a solar fraction of 0.8, minimizing daily operating costs to 2.11 USD and carbon emissions to ∼ 39.1 kgCO2. The system maintains an average PMV of 0.14, an operative temperature of 25.63 °C, and a coefficient of performance of 0.72. The study also explores the impact of varying thermal comfort constraints, ventilation rates, and inlet air temperatures on system performance. Stricter comfort constraints (PMV=-0.2 to 0.2) increase costs and emissions by 30.96 % and 37.5 % respectively, due to increased reliance on the natural gas boiler. Doubling the ventilation rate based on fresh outdoor air increases daily costs and emissions by 19 % and 22.6 % respectively. Conversely, utilizing a supplementary system to supply ventilation air at 25 °C significantly reduces costs and emissions by 26.2 % and 25.4 % respectively, and increases the solar fraction to 0.92. Compared to a conventional system powered solely by a natural gas boiler, the solar-powered system achieves substantial cost savings (45.9 %), reduced carbon emissions (52.5 %), and improved thermal comfort, highlighting the potential of this technology for sustainable building operations.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Energy Conversion and Management
Energy Conversion and Management 工程技术-力学
CiteScore
19.00
自引率
11.50%
发文量
1304
审稿时长
17 days
期刊介绍: The journal Energy Conversion and Management provides a forum for publishing original contributions and comprehensive technical review articles of interdisciplinary and original research on all important energy topics. The topics considered include energy generation, utilization, conversion, storage, transmission, conservation, management and sustainability. These topics typically involve various types of energy such as mechanical, thermal, nuclear, chemical, electromagnetic, magnetic and electric. These energy types cover all known energy resources, including renewable resources (e.g., solar, bio, hydro, wind, geothermal and ocean energy), fossil fuels and nuclear resources.
期刊最新文献
Cutting-edge biomass gasification technologies for renewable energy generation and achieving net zero emissions Efficient framework for energy management of microgrid installed in Aljouf region considering renewable energy and electric vehicles Evaluating fuel cell power systems for coastal and inland waterway vessels: Technical and economic perspectives Biomimetic low carbonization efficient solar-driven thermochemical energy storage reactor design inspired by the diatoms’ superior photosynthesis capacity Reducing the lifecycle carbon emissions of rice straw-to-methanol for alternative marine fuel through self-generation and renewable electricity
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1