开发纳米材料支撑的分子印迹聚合物/受体样传感器,用于检测二元混合物中的罗伐他汀

IF 4.1 Q1 CHEMISTRY, ANALYTICAL Talanta Open Pub Date : 2024-11-03 DOI:10.1016/j.talo.2024.100376
Mahdi Gharibi , Ensar Piskin , Nadia Bounoua , Ahmet Cetinkaya , Sibel A. Ozkan
{"title":"开发纳米材料支撑的分子印迹聚合物/受体样传感器,用于检测二元混合物中的罗伐他汀","authors":"Mahdi Gharibi ,&nbsp;Ensar Piskin ,&nbsp;Nadia Bounoua ,&nbsp;Ahmet Cetinkaya ,&nbsp;Sibel A. Ozkan","doi":"10.1016/j.talo.2024.100376","DOIUrl":null,"url":null,"abstract":"<div><div>Statins reduce cholesterol synthesis by inhibiting the enzyme hydroxymethylglutaryl-CoA (HMG-CoA) reductase. Rosuvastatin (ROS) is a statin drug used to prevent cardiovascular diseases and treat abnormal lipids. This study describes the design and fabrication of a nanomaterial-assisted molecularly imprinted polymer (MIP)-based electrochemical sensor for ROS determination. In addition, MIP-based electrochemical sensors were designed to detect ROS in both standard solutions and serum samples. In the MIP-based electrochemical sensor developed via the photopolymerization (PP) technique on the glassy carbon electrode (GCE) surface, were used zinc oxide nanoparticles (ZnO NPs) as a pore former, p-aminobenzoic acid (p-ABA) as functional monomer, ROS as template molecule. Electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV), and scanning electron microscopy (SEM) techniques were used to carry out detailed characterizations concerning surface morphology and electrochemistry. Under optimized experimental conditions, the linearity range of the designed sensor was found 1.0 × 10<sup>−13</sup>–1.0 × 10<sup>−12</sup> M. The superior selectivity of the MIP-based sensor against ROS in the presence of their binary mixtures was confirmed by interference studies. The recovery rates of the MIP-based sensors were calculated as 100.35 % and 99.16 % in commercial tablet form and serum samples, respectively. Moreover, the proposed sensor's relative selectivity coefficient (k′) was calculated, and it provided good selectivity for ROS over the NIP sensor. In conclusion, this newly developed sensor offers an advantageous approach for selective, sensitive, rapid and cost-effective analysis of ROS from binary mixtures. Additionally, this study is the first electrochemical sensor using nanomaterial-assisted MIP technology for ROS analysis, and its sensitivity is higher than that of other studies in the literature.</div></div>","PeriodicalId":436,"journal":{"name":"Talanta Open","volume":"10 ","pages":"Article 100376"},"PeriodicalIF":4.1000,"publicationDate":"2024-11-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Development of nanomaterial-supported molecularly imprinted polymer/receptor-like sensor for the detection of rosuvastatin from binary mixtures\",\"authors\":\"Mahdi Gharibi ,&nbsp;Ensar Piskin ,&nbsp;Nadia Bounoua ,&nbsp;Ahmet Cetinkaya ,&nbsp;Sibel A. Ozkan\",\"doi\":\"10.1016/j.talo.2024.100376\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>Statins reduce cholesterol synthesis by inhibiting the enzyme hydroxymethylglutaryl-CoA (HMG-CoA) reductase. Rosuvastatin (ROS) is a statin drug used to prevent cardiovascular diseases and treat abnormal lipids. This study describes the design and fabrication of a nanomaterial-assisted molecularly imprinted polymer (MIP)-based electrochemical sensor for ROS determination. In addition, MIP-based electrochemical sensors were designed to detect ROS in both standard solutions and serum samples. In the MIP-based electrochemical sensor developed via the photopolymerization (PP) technique on the glassy carbon electrode (GCE) surface, were used zinc oxide nanoparticles (ZnO NPs) as a pore former, p-aminobenzoic acid (p-ABA) as functional monomer, ROS as template molecule. Electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV), and scanning electron microscopy (SEM) techniques were used to carry out detailed characterizations concerning surface morphology and electrochemistry. Under optimized experimental conditions, the linearity range of the designed sensor was found 1.0 × 10<sup>−13</sup>–1.0 × 10<sup>−12</sup> M. The superior selectivity of the MIP-based sensor against ROS in the presence of their binary mixtures was confirmed by interference studies. The recovery rates of the MIP-based sensors were calculated as 100.35 % and 99.16 % in commercial tablet form and serum samples, respectively. Moreover, the proposed sensor's relative selectivity coefficient (k′) was calculated, and it provided good selectivity for ROS over the NIP sensor. In conclusion, this newly developed sensor offers an advantageous approach for selective, sensitive, rapid and cost-effective analysis of ROS from binary mixtures. Additionally, this study is the first electrochemical sensor using nanomaterial-assisted MIP technology for ROS analysis, and its sensitivity is higher than that of other studies in the literature.</div></div>\",\"PeriodicalId\":436,\"journal\":{\"name\":\"Talanta Open\",\"volume\":\"10 \",\"pages\":\"Article 100376\"},\"PeriodicalIF\":4.1000,\"publicationDate\":\"2024-11-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Talanta Open\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2666831924000900\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Talanta Open","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2666831924000900","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

他汀类药物通过抑制羟甲基戊二酰-CoA(HMG-CoA)还原酶来减少胆固醇的合成。瑞舒伐他汀(ROS)是一种他汀类药物,用于预防心血管疾病和治疗血脂异常。本研究介绍了一种基于纳米材料辅助的分子印迹聚合物(MIP)电化学传感器的设计和制造,用于测定 ROS。此外,还设计了基于 MIP 的电化学传感器来检测标准溶液和血清样品中的 ROS。在玻璃碳电极(GCE)表面通过光聚合(PP)技术开发的基于 MIP 的电化学传感器中,使用氧化锌纳米颗粒(ZnO NPs)作为孔隙形成剂,对氨基苯甲酸(p-ABA)作为功能单体,ROS 作为模板分子。实验采用了电化学阻抗谱(EIS)、循环伏安法(CV)和扫描电子显微镜(SEM)技术,对表面形貌和电化学特性进行了详细分析。在优化的实验条件下,所设计传感器的线性范围为 1.0 × 10-13-1.0 × 10-12 M。根据计算,基于 MIP 的传感器在商业片剂和血清样品中的回收率分别为 100.35 % 和 99.16 %。此外,还计算了拟议传感器的相对选择性系数(k′),与 NIP 传感器相比,该传感器对 ROS 具有良好的选择性。总之,这种新开发的传感器为选择性、灵敏、快速和经济高效地分析二元混合物中的 ROS 提供了一种有利的方法。此外,该研究是首个使用纳米材料辅助 MIP 技术进行 ROS 分析的电化学传感器,其灵敏度高于其他文献研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Development of nanomaterial-supported molecularly imprinted polymer/receptor-like sensor for the detection of rosuvastatin from binary mixtures
Statins reduce cholesterol synthesis by inhibiting the enzyme hydroxymethylglutaryl-CoA (HMG-CoA) reductase. Rosuvastatin (ROS) is a statin drug used to prevent cardiovascular diseases and treat abnormal lipids. This study describes the design and fabrication of a nanomaterial-assisted molecularly imprinted polymer (MIP)-based electrochemical sensor for ROS determination. In addition, MIP-based electrochemical sensors were designed to detect ROS in both standard solutions and serum samples. In the MIP-based electrochemical sensor developed via the photopolymerization (PP) technique on the glassy carbon electrode (GCE) surface, were used zinc oxide nanoparticles (ZnO NPs) as a pore former, p-aminobenzoic acid (p-ABA) as functional monomer, ROS as template molecule. Electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV), and scanning electron microscopy (SEM) techniques were used to carry out detailed characterizations concerning surface morphology and electrochemistry. Under optimized experimental conditions, the linearity range of the designed sensor was found 1.0 × 10−13–1.0 × 10−12 M. The superior selectivity of the MIP-based sensor against ROS in the presence of their binary mixtures was confirmed by interference studies. The recovery rates of the MIP-based sensors were calculated as 100.35 % and 99.16 % in commercial tablet form and serum samples, respectively. Moreover, the proposed sensor's relative selectivity coefficient (k′) was calculated, and it provided good selectivity for ROS over the NIP sensor. In conclusion, this newly developed sensor offers an advantageous approach for selective, sensitive, rapid and cost-effective analysis of ROS from binary mixtures. Additionally, this study is the first electrochemical sensor using nanomaterial-assisted MIP technology for ROS analysis, and its sensitivity is higher than that of other studies in the literature.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Talanta Open
Talanta Open Chemistry-Analytical Chemistry
CiteScore
5.20
自引率
0.00%
发文量
86
审稿时长
49 days
期刊最新文献
Continuous-flow analysis of nitrogen compounds in environmental water using a copper–zinc reduction coil Development of engineered Zn-MOF/g-C3N4 based photoelectrochemical system for real-time sensors and removal of naproxen in wastewater Development of nanomaterial-supported molecularly imprinted polymer/receptor-like sensor for the detection of rosuvastatin from binary mixtures Trace-level quantification of NDMA in levosulpuride active pharmaceutical ingredient and tablet formulation Using UFLC-MS/MS Enhancing isomer specificity in mass spectrometry by combining silver ion adduction and ion mobility
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1