{"title":"基于 Au@Pt@Pd 纳米酶的侧流免疫分析法定量检测鼻拭子样本中的 SARS-CoV-2 核头壳蛋白","authors":"Chengcheng Li,&nbsp;Jinhui Lu,&nbsp;Chao Xiang,&nbsp;Enhui Zhang,&nbsp;Xiaofang Tian,&nbsp;Ling Zhang,&nbsp;Tingting Li,&nbsp;Chengyao Li","doi":"10.1007/s00604-024-06819-x","DOIUrl":null,"url":null,"abstract":"<div><p>Three-metal-core-shell nanoparticles (Au@Pt@PdNPs) providing excellent peroxidase-like activity were applied in lateral flow immunoassay (LFIA), designated as Au@Pt@Pd-LFIA, for detecting the nucleocapsid protein (NP) of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). An Au@Pt@Pd-LFIA was developed for quantitatively testing of SARS-CoV-2 NP with a range 0.12–31.25 ng/mL. The limit of detection (LOD) of Au@Pt@Pd-LFIA strip was 0.06 ng/mL, which was 16-fold or eightfold more sensitive than that of the gold lateral flow immunoassay (Au-LFIA) and the gold flower flow immunoassay (AF-LFIA) strips, respectively. For detection of clinical samples from nasal swabs using test strips, Au@Pt@Pd-LFIA had 84.09% sensitivity, 100% specificity, and 92.55% accuracy. In terms of detection time, the testing of Au@Pt@Pd-LFIA strip was 16 min similar to Au-LFIA (15 min) and AF-LFIA (10 min), but much shorter than ELISA (2 h). In conclusion, Au@Pt@Pd-LFIA is a sensitive, rapid, and simple test for quantitative detection of SARS-CoV-2 NP in nasal swab samples.</p><h3>Graphical Abstract</h3>\n<div><figure><div><div><picture><source><img></source></picture></div></div></figure></div></div>","PeriodicalId":705,"journal":{"name":"Microchimica Acta","volume":"191 12","pages":""},"PeriodicalIF":5.3000,"publicationDate":"2024-11-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Au@Pt@Pd nanozymes based lateral flow immunoassay for quantitative detection of SARS-CoV-2 nucleocapsid protein in nasal swab samples\",\"authors\":\"Chengcheng Li,&nbsp;Jinhui Lu,&nbsp;Chao Xiang,&nbsp;Enhui Zhang,&nbsp;Xiaofang Tian,&nbsp;Ling Zhang,&nbsp;Tingting Li,&nbsp;Chengyao Li\",\"doi\":\"10.1007/s00604-024-06819-x\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Three-metal-core-shell nanoparticles (Au@Pt@PdNPs) providing excellent peroxidase-like activity were applied in lateral flow immunoassay (LFIA), designated as Au@Pt@Pd-LFIA, for detecting the nucleocapsid protein (NP) of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). An Au@Pt@Pd-LFIA was developed for quantitatively testing of SARS-CoV-2 NP with a range 0.12–31.25 ng/mL. The limit of detection (LOD) of Au@Pt@Pd-LFIA strip was 0.06 ng/mL, which was 16-fold or eightfold more sensitive than that of the gold lateral flow immunoassay (Au-LFIA) and the gold flower flow immunoassay (AF-LFIA) strips, respectively. For detection of clinical samples from nasal swabs using test strips, Au@Pt@Pd-LFIA had 84.09% sensitivity, 100% specificity, and 92.55% accuracy. In terms of detection time, the testing of Au@Pt@Pd-LFIA strip was 16 min similar to Au-LFIA (15 min) and AF-LFIA (10 min), but much shorter than ELISA (2 h). In conclusion, Au@Pt@Pd-LFIA is a sensitive, rapid, and simple test for quantitative detection of SARS-CoV-2 NP in nasal swab samples.</p><h3>Graphical Abstract</h3>\\n<div><figure><div><div><picture><source><img></source></picture></div></div></figure></div></div>\",\"PeriodicalId\":705,\"journal\":{\"name\":\"Microchimica Acta\",\"volume\":\"191 12\",\"pages\":\"\"},\"PeriodicalIF\":5.3000,\"publicationDate\":\"2024-11-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Microchimica Acta\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://link.springer.com/article/10.1007/s00604-024-06819-x\",\"RegionNum\":2,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Microchimica Acta","FirstCategoryId":"92","ListUrlMain":"https://link.springer.com/article/10.1007/s00604-024-06819-x","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

将具有优异过氧化物酶样活性的三金属核壳纳米粒子(Au@Pt@PdNPs)应用于侧流免疫分析(LFIA),并命名为Au@Pt@Pd-LFIA,用于检测严重急性呼吸系统综合征冠状病毒2(SARS-CoV-2)的核壳蛋白(NP)。所开发的 Au@Pt@Pd-LFIA 可用于定量检测 SARS-CoV-2 NP,检测范围为 0.12-31.25 ng/mL。Au@Pt@Pd-LFIA条的检出限为0.06 ng/mL,灵敏度分别是金侧流免疫分析条(Au-LFIA)和金花流免疫分析条(AF-LFIA)的16倍和8倍。在使用试纸检测鼻拭子临床样本时,Au@Pt@Pd-LFIA 的灵敏度为 84.09%,特异度为 100%,准确度为 92.55%。就检测时间而言,Au@Pt@Pd-LFIA 试条的检测时间为 16 分钟,与 Au-LFIA(15 分钟)和 AF-LFIA (10 分钟)相似,但比 ELISA(2 小时)短得多。总之,Au@Pt@Pd-LFIA是一种灵敏、快速、简便的鼻拭子样本中SARS-CoV-2 NP定量检测方法。 图文摘要
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Au@Pt@Pd nanozymes based lateral flow immunoassay for quantitative detection of SARS-CoV-2 nucleocapsid protein in nasal swab samples

Three-metal-core-shell nanoparticles (Au@Pt@PdNPs) providing excellent peroxidase-like activity were applied in lateral flow immunoassay (LFIA), designated as Au@Pt@Pd-LFIA, for detecting the nucleocapsid protein (NP) of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). An Au@Pt@Pd-LFIA was developed for quantitatively testing of SARS-CoV-2 NP with a range 0.12–31.25 ng/mL. The limit of detection (LOD) of Au@Pt@Pd-LFIA strip was 0.06 ng/mL, which was 16-fold or eightfold more sensitive than that of the gold lateral flow immunoassay (Au-LFIA) and the gold flower flow immunoassay (AF-LFIA) strips, respectively. For detection of clinical samples from nasal swabs using test strips, Au@Pt@Pd-LFIA had 84.09% sensitivity, 100% specificity, and 92.55% accuracy. In terms of detection time, the testing of Au@Pt@Pd-LFIA strip was 16 min similar to Au-LFIA (15 min) and AF-LFIA (10 min), but much shorter than ELISA (2 h). In conclusion, Au@Pt@Pd-LFIA is a sensitive, rapid, and simple test for quantitative detection of SARS-CoV-2 NP in nasal swab samples.

Graphical Abstract

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Microchimica Acta
Microchimica Acta 化学-分析化学
CiteScore
9.80
自引率
5.30%
发文量
410
审稿时长
2.7 months
期刊介绍: As a peer-reviewed journal for analytical sciences and technologies on the micro- and nanoscale, Microchimica Acta has established itself as a premier forum for truly novel approaches in chemical and biochemical analysis. Coverage includes methods and devices that provide expedient solutions to the most contemporary demands in this area. Examples are point-of-care technologies, wearable (bio)sensors, in-vivo-monitoring, micro/nanomotors and materials based on synthetic biology as well as biomedical imaging and targeting.
期刊最新文献
A portable colorimetric immunosensor for highly sensitive point-of-care testing of leather artifacts Photoelectrochemical immunosensor for chloramphenicol detection based on cation exchange reaction-mediacted photocurrent enhancement of ZnIn2S4/TiO2/Ti3C2 MXene coupled with controlled-release strategy Magnetic poly(phages) encoded probes-based dual-mode assay for rapid determination of live Escherichia coli and Hafnia paralvei based on microfluidic chip and ATP bioluminescence meter. In-situ oxidative polymerization of dopamine triggered by CuO2 in acidic condition and application in “turn-off” sensing Bi2S3/BiOCl heterojunction-based photoelectrochemical aptasensor for ultrasensitive assay of fumonisin B1 via signal amplification with in situ grown Ag2S quantum dots
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1