{"title":"具有不确定组织电特性的多层平面皮肤模型中上皮/吸收功率密度的随机分析","authors":"Anna Susnjara Nejasmic;Dragan Poljak","doi":"10.1029/2024RS007988","DOIUrl":null,"url":null,"abstract":"Stochastic analysis of the absorbed power density (APD) on skin surface exposed to radiation of halfwave dipole at 10, 30 and 90 GHz and for different antenna-body distances is presented. Skin tissue is modeled as a half-space consisting of one layer (skin) or three layers (skin, fat and muscle) whose permittivities and conductivities are uncertain. Deterministic part is based on numerical solution of Pocklington equation via Galerkin Bubnov Indirect Boundary Element method (GB-IBEM) and numerical integration of the corresponding field integrals. Uncertainty from tissue electric parameters is propagated to APD via nonintrusive Stochastic Collocation method (SCM) in order to compute stochastic moments of APD. For 1-layered model APD stochastic moments are computed with 3 deterministic simulations. On the other hand APD mean and variance for 3 layered model are successfully computed with 13 deterministic simulations while skewness and kurtosis require 85 deterministic simulations. The ratio of APD standard deviation and mean decreases with frequency thus indicating that the uncertainty in the tissue electric properties has smaller effect on APD uncertainty at higher frequencies. Finally, sensitivity analysis carried out for both 1-layered and 3-layered models indicates the same conclusions. At 10 GHz skin permittivity and conductivity are the two most important parameters. However, as frequency increases the impact of skin conductivity prevails. This indicates that in frequency range 10-90 GHz the APD uncertainty quantification and sensitivity analysis can be carried out by using only 2-dimensional stochastic model.","PeriodicalId":49638,"journal":{"name":"Radio Science","volume":"59 10","pages":"1-15"},"PeriodicalIF":1.6000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Stochastic analysis of epithelial/absorbed power density in multilayered planar skin model with uncertain tissue electric properties\",\"authors\":\"Anna Susnjara Nejasmic;Dragan Poljak\",\"doi\":\"10.1029/2024RS007988\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Stochastic analysis of the absorbed power density (APD) on skin surface exposed to radiation of halfwave dipole at 10, 30 and 90 GHz and for different antenna-body distances is presented. Skin tissue is modeled as a half-space consisting of one layer (skin) or three layers (skin, fat and muscle) whose permittivities and conductivities are uncertain. Deterministic part is based on numerical solution of Pocklington equation via Galerkin Bubnov Indirect Boundary Element method (GB-IBEM) and numerical integration of the corresponding field integrals. Uncertainty from tissue electric parameters is propagated to APD via nonintrusive Stochastic Collocation method (SCM) in order to compute stochastic moments of APD. For 1-layered model APD stochastic moments are computed with 3 deterministic simulations. On the other hand APD mean and variance for 3 layered model are successfully computed with 13 deterministic simulations while skewness and kurtosis require 85 deterministic simulations. The ratio of APD standard deviation and mean decreases with frequency thus indicating that the uncertainty in the tissue electric properties has smaller effect on APD uncertainty at higher frequencies. Finally, sensitivity analysis carried out for both 1-layered and 3-layered models indicates the same conclusions. At 10 GHz skin permittivity and conductivity are the two most important parameters. However, as frequency increases the impact of skin conductivity prevails. This indicates that in frequency range 10-90 GHz the APD uncertainty quantification and sensitivity analysis can be carried out by using only 2-dimensional stochastic model.\",\"PeriodicalId\":49638,\"journal\":{\"name\":\"Radio Science\",\"volume\":\"59 10\",\"pages\":\"1-15\"},\"PeriodicalIF\":1.6000,\"publicationDate\":\"2024-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Radio Science\",\"FirstCategoryId\":\"94\",\"ListUrlMain\":\"https://ieeexplore.ieee.org/document/10747579/\",\"RegionNum\":4,\"RegionCategory\":\"地球科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ASTRONOMY & ASTROPHYSICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radio Science","FirstCategoryId":"94","ListUrlMain":"https://ieeexplore.ieee.org/document/10747579/","RegionNum":4,"RegionCategory":"地球科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ASTRONOMY & ASTROPHYSICS","Score":null,"Total":0}
Stochastic analysis of epithelial/absorbed power density in multilayered planar skin model with uncertain tissue electric properties
Stochastic analysis of the absorbed power density (APD) on skin surface exposed to radiation of halfwave dipole at 10, 30 and 90 GHz and for different antenna-body distances is presented. Skin tissue is modeled as a half-space consisting of one layer (skin) or three layers (skin, fat and muscle) whose permittivities and conductivities are uncertain. Deterministic part is based on numerical solution of Pocklington equation via Galerkin Bubnov Indirect Boundary Element method (GB-IBEM) and numerical integration of the corresponding field integrals. Uncertainty from tissue electric parameters is propagated to APD via nonintrusive Stochastic Collocation method (SCM) in order to compute stochastic moments of APD. For 1-layered model APD stochastic moments are computed with 3 deterministic simulations. On the other hand APD mean and variance for 3 layered model are successfully computed with 13 deterministic simulations while skewness and kurtosis require 85 deterministic simulations. The ratio of APD standard deviation and mean decreases with frequency thus indicating that the uncertainty in the tissue electric properties has smaller effect on APD uncertainty at higher frequencies. Finally, sensitivity analysis carried out for both 1-layered and 3-layered models indicates the same conclusions. At 10 GHz skin permittivity and conductivity are the two most important parameters. However, as frequency increases the impact of skin conductivity prevails. This indicates that in frequency range 10-90 GHz the APD uncertainty quantification and sensitivity analysis can be carried out by using only 2-dimensional stochastic model.
期刊介绍:
Radio Science (RDS) publishes original scientific contributions on radio-frequency electromagnetic-propagation and its applications. Contributions covering measurement, modelling, prediction and forecasting techniques pertinent to fields and waves - including antennas, signals and systems, the terrestrial and space environment and radio propagation problems in radio astronomy - are welcome. Contributions may address propagation through, interaction with, and remote sensing of structures, geophysical media, plasmas, and materials, as well as the application of radio frequency electromagnetic techniques to remote sensing of the Earth and other bodies in the solar system.