带有正电荷的抗血栓涂层通过控制因子 XII 与生物界面的结合防止接触激活

IF 8.9 2区 环境科学与生态学 Q1 ENGINEERING, ENVIRONMENTAL Environmental Science & Technology Letters Environ. Pub Date : 2024-11-12 DOI:10.1038/s41563-024-02046-0
Haifeng Ji, Kai Yu, Srinivas Abbina, Lin Xu, Tao Xu, Shengjun Cheng, Sreeparna Vappala, S. M. Amin Arefi, Md Mohosin Rana, Irina Chafeeva, Matthew Drayton, Kevin Gonzalez, Yun Liu, Dana Grecov, Edward M. Conway, Weifeng Zhao, Changsheng Zhao, Jayachandran N. Kizhakkedathu
{"title":"带有正电荷的抗血栓涂层通过控制因子 XII 与生物界面的结合防止接触激活","authors":"Haifeng Ji, Kai Yu, Srinivas Abbina, Lin Xu, Tao Xu, Shengjun Cheng, Sreeparna Vappala, S. M. Amin Arefi, Md Mohosin Rana, Irina Chafeeva, Matthew Drayton, Kevin Gonzalez, Yun Liu, Dana Grecov, Edward M. Conway, Weifeng Zhao, Changsheng Zhao, Jayachandran N. Kizhakkedathu","doi":"10.1038/s41563-024-02046-0","DOIUrl":null,"url":null,"abstract":"<p>Antithrombotic surfaces that prevent coagulation activation without interfering with haemostasis are required for blood-contacting devices. Such materials would restrain device-induced thrombogenesis and decrease the need for anticoagulant use, thereby reducing unwanted bleeding. Here, by optimizing the interactions with coagulation factor XII rather than preventing its surface adsorption, we develop a substrate-independent antithrombotic polymeric coating with sheltered positive charges. The antithrombic properties of the coating were demonstrated in vitro with human blood and in vivo using a carotid artery–jugular vein shunt model in rabbits. The coating exhibits a strong interaction with factor XII, but results in a low reciprocal activation of the contact pathway that triggers clot formation. These findings contradict the prevailing strategy of designing antithrombotic materials through protein-repelling surfaces. Overall, the polymeric coating we describe can benefit most blood-contacting devices and is a useful engineering guideline for designing surfaces with improved antithrombotic properties.</p>","PeriodicalId":37,"journal":{"name":"Environmental Science & Technology Letters Environ.","volume":null,"pages":null},"PeriodicalIF":8.9000,"publicationDate":"2024-11-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Antithrombotic coating with sheltered positive charges prevents contact activation by controlling factor XII–biointerface binding\",\"authors\":\"Haifeng Ji, Kai Yu, Srinivas Abbina, Lin Xu, Tao Xu, Shengjun Cheng, Sreeparna Vappala, S. M. Amin Arefi, Md Mohosin Rana, Irina Chafeeva, Matthew Drayton, Kevin Gonzalez, Yun Liu, Dana Grecov, Edward M. Conway, Weifeng Zhao, Changsheng Zhao, Jayachandran N. Kizhakkedathu\",\"doi\":\"10.1038/s41563-024-02046-0\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>Antithrombotic surfaces that prevent coagulation activation without interfering with haemostasis are required for blood-contacting devices. Such materials would restrain device-induced thrombogenesis and decrease the need for anticoagulant use, thereby reducing unwanted bleeding. Here, by optimizing the interactions with coagulation factor XII rather than preventing its surface adsorption, we develop a substrate-independent antithrombotic polymeric coating with sheltered positive charges. The antithrombic properties of the coating were demonstrated in vitro with human blood and in vivo using a carotid artery–jugular vein shunt model in rabbits. The coating exhibits a strong interaction with factor XII, but results in a low reciprocal activation of the contact pathway that triggers clot formation. These findings contradict the prevailing strategy of designing antithrombotic materials through protein-repelling surfaces. Overall, the polymeric coating we describe can benefit most blood-contacting devices and is a useful engineering guideline for designing surfaces with improved antithrombotic properties.</p>\",\"PeriodicalId\":37,\"journal\":{\"name\":\"Environmental Science & Technology Letters Environ.\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":8.9000,\"publicationDate\":\"2024-11-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Environmental Science & Technology Letters Environ.\",\"FirstCategoryId\":\"88\",\"ListUrlMain\":\"https://doi.org/10.1038/s41563-024-02046-0\",\"RegionNum\":2,\"RegionCategory\":\"环境科学与生态学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ENGINEERING, ENVIRONMENTAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Environmental Science & Technology Letters Environ.","FirstCategoryId":"88","ListUrlMain":"https://doi.org/10.1038/s41563-024-02046-0","RegionNum":2,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, ENVIRONMENTAL","Score":null,"Total":0}
引用次数: 0

摘要

与血液接触的设备需要既能防止凝血活化又不影响止血的抗血栓表面。这种材料可抑制装置引起的血栓形成,减少抗凝剂的使用,从而减少不必要的出血。在这里,我们通过优化与凝血因子 XII 的相互作用,而不是阻止其表面吸附,开发出了一种不依赖于基底的抗血栓聚合物涂层,该涂层带有屏蔽正电荷。该涂层的抗血栓特性在体外用人血和体内用兔子颈动脉-颈静脉分流模型进行了验证。涂层与 XII 因子的相互作用很强,但引发血栓形成的接触途径的相互激活程度却很低。这些发现与通过蛋白质排斥表面设计抗血栓材料的主流策略相矛盾。总之,我们所描述的聚合物涂层可使大多数与血液接触的设备受益,是设计具有更好抗血栓性能的表面的有用工程指南。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Antithrombotic coating with sheltered positive charges prevents contact activation by controlling factor XII–biointerface binding

Antithrombotic surfaces that prevent coagulation activation without interfering with haemostasis are required for blood-contacting devices. Such materials would restrain device-induced thrombogenesis and decrease the need for anticoagulant use, thereby reducing unwanted bleeding. Here, by optimizing the interactions with coagulation factor XII rather than preventing its surface adsorption, we develop a substrate-independent antithrombotic polymeric coating with sheltered positive charges. The antithrombic properties of the coating were demonstrated in vitro with human blood and in vivo using a carotid artery–jugular vein shunt model in rabbits. The coating exhibits a strong interaction with factor XII, but results in a low reciprocal activation of the contact pathway that triggers clot formation. These findings contradict the prevailing strategy of designing antithrombotic materials through protein-repelling surfaces. Overall, the polymeric coating we describe can benefit most blood-contacting devices and is a useful engineering guideline for designing surfaces with improved antithrombotic properties.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Environmental Science & Technology Letters Environ.
Environmental Science & Technology Letters Environ. ENGINEERING, ENVIRONMENTALENVIRONMENTAL SC-ENVIRONMENTAL SCIENCES
CiteScore
17.90
自引率
3.70%
发文量
163
期刊介绍: Environmental Science & Technology Letters serves as an international forum for brief communications on experimental or theoretical results of exceptional timeliness in all aspects of environmental science, both pure and applied. Published as soon as accepted, these communications are summarized in monthly issues. Additionally, the journal features short reviews on emerging topics in environmental science and technology.
期刊最新文献
Correction to: A novel tool for arrhythmic risk stratification in desmoplakin gene variant carriers. The humanized platelet glycoprotein VI Fab inhibitor EMA601 protects from arterial thrombosis and ischaemic stroke in mice. Optical coherence tomography predictors of clinical outcomes after stent implantation: the ILUMIEN IV trial. The SEX-SHOCK score-the emperor's new clothes? Weekly Journal Scan: A large Chinese SPRINT supports 'the lower, the better' blood pressure in hypertensive patients at high cardiovascular risk.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1