粘弹性流体中的长直方形微通道,用于聚焦亚微米级颗粒和细菌

IF 5.3 2区 化学 Q1 CHEMISTRY, ANALYTICAL Microchimica Acta Pub Date : 2024-11-12 DOI:10.1007/s00604-024-06824-0
Youngseo Cho, Min-Ho Lee, SangWook Lee, Younghak Cho
{"title":"粘弹性流体中的长直方形微通道,用于聚焦亚微米级颗粒和细菌","authors":"Youngseo Cho,&nbsp;Min-Ho Lee,&nbsp;SangWook Lee,&nbsp;Younghak Cho","doi":"10.1007/s00604-024-06824-0","DOIUrl":null,"url":null,"abstract":"<div><p>A viscoelastic flow focusing device is presented that enables simple and robust focusing of submicron-sized particles in the channel center by optimizing operating conditions such as channel length, flow rate and poly(ethylene oxide) (PEO) concentration. Submicron-sized particles (up to 100 nm) can be easily focused to the channel center under viscoelastic fluid flow without any external force via a simply fabricated microchannel with a long channel length and a large square cross-section. The device was fabricated using a common soft lithography technique for the polydimethylsiloxane (PDMS) channel, which has a width of 50 μm, a height of 50 μm and a channel length of 27 cm. The extralong channel enabled submicron-sized particle focusing, even in a channel of a relatively large size with high flow rate, which can realize flow cytometric applications. The focusing performance was first demonstrated using submicron-sized polystyrene (PS) beads ranging from 870 nm to 50 nm and then using biological particles such as <i>E. coli</i> bacteria to demonstrate the biological feasibility of the device. The PS beads, which ranged in diameter from 870 nm to 100 nm, were focused to the center of the channel, achieving over 90% focusing efficiency for beads as small as 510 nm and 62% focusing efficiency for 100-nm beads. The device could also align a bacterial suspension in the center of the channel at flow rates up to 30 µL/min, demonstrating its biological importance. The ability of the developed device to align submicron-sized particles within a narrow flow stream in a highly robust manner is promising for various biological and clinical applications, such as distinguishing pathogenic bacteria and evaluating individual antibiotic responses in a single experiment.</p><h3>Graphical abstract</h3>\n<div><figure><div><div><picture><source><img></source></picture></div></div></figure></div></div>","PeriodicalId":705,"journal":{"name":"Microchimica Acta","volume":"191 12","pages":""},"PeriodicalIF":5.3000,"publicationDate":"2024-11-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A long straight square microchannel in viscoelastic fluid for focusing submicron-sized particles and bacteria\",\"authors\":\"Youngseo Cho,&nbsp;Min-Ho Lee,&nbsp;SangWook Lee,&nbsp;Younghak Cho\",\"doi\":\"10.1007/s00604-024-06824-0\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>A viscoelastic flow focusing device is presented that enables simple and robust focusing of submicron-sized particles in the channel center by optimizing operating conditions such as channel length, flow rate and poly(ethylene oxide) (PEO) concentration. Submicron-sized particles (up to 100 nm) can be easily focused to the channel center under viscoelastic fluid flow without any external force via a simply fabricated microchannel with a long channel length and a large square cross-section. The device was fabricated using a common soft lithography technique for the polydimethylsiloxane (PDMS) channel, which has a width of 50 μm, a height of 50 μm and a channel length of 27 cm. The extralong channel enabled submicron-sized particle focusing, even in a channel of a relatively large size with high flow rate, which can realize flow cytometric applications. The focusing performance was first demonstrated using submicron-sized polystyrene (PS) beads ranging from 870 nm to 50 nm and then using biological particles such as <i>E. coli</i> bacteria to demonstrate the biological feasibility of the device. The PS beads, which ranged in diameter from 870 nm to 100 nm, were focused to the center of the channel, achieving over 90% focusing efficiency for beads as small as 510 nm and 62% focusing efficiency for 100-nm beads. The device could also align a bacterial suspension in the center of the channel at flow rates up to 30 µL/min, demonstrating its biological importance. The ability of the developed device to align submicron-sized particles within a narrow flow stream in a highly robust manner is promising for various biological and clinical applications, such as distinguishing pathogenic bacteria and evaluating individual antibiotic responses in a single experiment.</p><h3>Graphical abstract</h3>\\n<div><figure><div><div><picture><source><img></source></picture></div></div></figure></div></div>\",\"PeriodicalId\":705,\"journal\":{\"name\":\"Microchimica Acta\",\"volume\":\"191 12\",\"pages\":\"\"},\"PeriodicalIF\":5.3000,\"publicationDate\":\"2024-11-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Microchimica Acta\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://link.springer.com/article/10.1007/s00604-024-06824-0\",\"RegionNum\":2,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Microchimica Acta","FirstCategoryId":"92","ListUrlMain":"https://link.springer.com/article/10.1007/s00604-024-06824-0","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

本文介绍了一种粘弹性流动聚焦装置,通过优化通道长度、流速和聚环氧乙烷(PEO)浓度等操作条件,可将亚微米级颗粒简单而稳健地聚焦到通道中心。在粘弹性流体流动的作用下,亚微米大小的颗粒(最多 100 纳米)可以通过一个简单制造的长通道长度和大方形横截面的微通道,在没有任何外力的情况下轻松聚焦到通道中心。该装置采用普通的软光刻技术制作聚二甲基硅氧烷(PDMS)通道,其宽度为 50 微米,高度为 50 微米,通道长度为 27 厘米。即使在一个相对较大的通道中,外长通道也能实现亚微米级粒子的聚焦,而且流速较高,从而实现了流式细胞仪的应用。首先使用 870 纳米到 50 纳米的亚微米级聚苯乙烯(PS)珠演示了聚焦性能,然后使用大肠杆菌等生物颗粒演示了该装置的生物可行性。直径从 870 纳米到 100 纳米不等的聚苯乙烯微珠被聚焦到通道中心,小至 510 纳米的微珠的聚焦效率超过 90%,100 纳米的微珠的聚焦效率为 62%。该装置还能以高达 30 µL/min 的流速将细菌悬浮液对准通道中心,显示了其生物学重要性。所开发的装置能够以高度稳健的方式在狭窄的气流中对准亚微米大小的颗粒,这为各种生物和临床应用带来了希望,例如在一次实验中区分病原菌和评估单个抗生素的反应。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A long straight square microchannel in viscoelastic fluid for focusing submicron-sized particles and bacteria

A viscoelastic flow focusing device is presented that enables simple and robust focusing of submicron-sized particles in the channel center by optimizing operating conditions such as channel length, flow rate and poly(ethylene oxide) (PEO) concentration. Submicron-sized particles (up to 100 nm) can be easily focused to the channel center under viscoelastic fluid flow without any external force via a simply fabricated microchannel with a long channel length and a large square cross-section. The device was fabricated using a common soft lithography technique for the polydimethylsiloxane (PDMS) channel, which has a width of 50 μm, a height of 50 μm and a channel length of 27 cm. The extralong channel enabled submicron-sized particle focusing, even in a channel of a relatively large size with high flow rate, which can realize flow cytometric applications. The focusing performance was first demonstrated using submicron-sized polystyrene (PS) beads ranging from 870 nm to 50 nm and then using biological particles such as E. coli bacteria to demonstrate the biological feasibility of the device. The PS beads, which ranged in diameter from 870 nm to 100 nm, were focused to the center of the channel, achieving over 90% focusing efficiency for beads as small as 510 nm and 62% focusing efficiency for 100-nm beads. The device could also align a bacterial suspension in the center of the channel at flow rates up to 30 µL/min, demonstrating its biological importance. The ability of the developed device to align submicron-sized particles within a narrow flow stream in a highly robust manner is promising for various biological and clinical applications, such as distinguishing pathogenic bacteria and evaluating individual antibiotic responses in a single experiment.

Graphical abstract

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Microchimica Acta
Microchimica Acta 化学-分析化学
CiteScore
9.80
自引率
5.30%
发文量
410
审稿时长
2.7 months
期刊介绍: As a peer-reviewed journal for analytical sciences and technologies on the micro- and nanoscale, Microchimica Acta has established itself as a premier forum for truly novel approaches in chemical and biochemical analysis. Coverage includes methods and devices that provide expedient solutions to the most contemporary demands in this area. Examples are point-of-care technologies, wearable (bio)sensors, in-vivo-monitoring, micro/nanomotors and materials based on synthetic biology as well as biomedical imaging and targeting.
期刊最新文献
Gold-grafted melamine sponge as surface-enhanced Raman spectroscopy substrate for enzyme-linked immunoassay of mycotoxins in cereal samples Fluorescent core–shell SiO2@COF composite for ultra-sensitive detection of cysteine and homocysteine Chemiresistive sensor array for quantitative prediction of CO and NO2 gas concentrations in their mixture using machine learning algorithms Detection of micro- and nanoplastic particles in leafy green vegetables by SERS coupled with gold-silver core–shell nanoparticles Conjugated hypercrosslinked polymers for in situ imprinting, selective sorption, and fluorescent turn-on sensing of oxalic acid
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1