一种新颖的气体传感器阵列校准方案,用于建立更精确的混合气体测量模型

IF 8.2 1区 化学 Q1 CHEMISTRY, ANALYTICAL ACS Sensors Pub Date : 2024-11-13 DOI:10.1021/acssensors.4c01867
Yilun Ma, Xingchang Qiu, Zaihua Duan, Lili Liu, Juan Li, Yuanming Wu, Zhen Yuan, Yadong Jiang, Huiling Tai
{"title":"一种新颖的气体传感器阵列校准方案,用于建立更精确的混合气体测量模型","authors":"Yilun Ma, Xingchang Qiu, Zaihua Duan, Lili Liu, Juan Li, Yuanming Wu, Zhen Yuan, Yadong Jiang, Huiling Tai","doi":"10.1021/acssensors.4c01867","DOIUrl":null,"url":null,"abstract":"Gas sensor arrays (GSAs) usually encounter challenges due to the cross-contamination of mixed gases, leading to reduced accuracy in measuring gas mixtures. However, with the advent of artificial intelligence, there is a promising avenue for addressing this issue effectively. In pursuit of more accurate mixed gas measurements, we proposed a measurement model leveraging neural networks. Our approach involved employing the encoder of an autoencoder network (AEN) to extract features from experimental data, while fully connected layers were utilized for predicting concentrations of mixed gases. To refine the neural network parameters, we employed a variational autoencoder to generate additional data resembling the distribution of experimental data. Subsequently, we designed a domain difference maximum entropy technique to identify optimal concentration points for the calibration data. These calibration points were instrumental in training the fully connected layers, enhancing the model’s accuracy. During practical usage, with the AEN configuration fixed, the model can be fine-tuned by using a small subset of test points across large-scale GSA deployments. Simulation and practical measurement results demonstrated the efficacy of our proposed measurement model, boasting high accuracy, with confidence intervals for relative errors of the four gas measurements below 3% at the 95% confidence level. Besides, the calibration scheme reduced the number of test points compared with traditional methods, reducing the cost of labor and equipment.","PeriodicalId":24,"journal":{"name":"ACS Sensors","volume":"15 1","pages":""},"PeriodicalIF":8.2000,"publicationDate":"2024-11-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A Novel Calibration Scheme of Gas Sensor Array for a More Accurate Measurement Model of Mixed Gases\",\"authors\":\"Yilun Ma, Xingchang Qiu, Zaihua Duan, Lili Liu, Juan Li, Yuanming Wu, Zhen Yuan, Yadong Jiang, Huiling Tai\",\"doi\":\"10.1021/acssensors.4c01867\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Gas sensor arrays (GSAs) usually encounter challenges due to the cross-contamination of mixed gases, leading to reduced accuracy in measuring gas mixtures. However, with the advent of artificial intelligence, there is a promising avenue for addressing this issue effectively. In pursuit of more accurate mixed gas measurements, we proposed a measurement model leveraging neural networks. Our approach involved employing the encoder of an autoencoder network (AEN) to extract features from experimental data, while fully connected layers were utilized for predicting concentrations of mixed gases. To refine the neural network parameters, we employed a variational autoencoder to generate additional data resembling the distribution of experimental data. Subsequently, we designed a domain difference maximum entropy technique to identify optimal concentration points for the calibration data. These calibration points were instrumental in training the fully connected layers, enhancing the model’s accuracy. During practical usage, with the AEN configuration fixed, the model can be fine-tuned by using a small subset of test points across large-scale GSA deployments. Simulation and practical measurement results demonstrated the efficacy of our proposed measurement model, boasting high accuracy, with confidence intervals for relative errors of the four gas measurements below 3% at the 95% confidence level. Besides, the calibration scheme reduced the number of test points compared with traditional methods, reducing the cost of labor and equipment.\",\"PeriodicalId\":24,\"journal\":{\"name\":\"ACS Sensors\",\"volume\":\"15 1\",\"pages\":\"\"},\"PeriodicalIF\":8.2000,\"publicationDate\":\"2024-11-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACS Sensors\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://doi.org/10.1021/acssensors.4c01867\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Sensors","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1021/acssensors.4c01867","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

气体传感器阵列(GSA)通常会遇到混合气体交叉污染的挑战,导致测量混合气体的精度降低。然而,随着人工智能的出现,有效解决这一问题的途径大有可为。为了实现更精确的混合气体测量,我们提出了一种利用神经网络的测量模型。我们的方法包括利用自动编码器网络(AEN)的编码器从实验数据中提取特征,同时利用全连接层预测混合气体的浓度。为了完善神经网络参数,我们采用了变异自动编码器来生成与实验数据分布相似的额外数据。随后,我们设计了一种域差最大熵技术,以确定校准数据的最佳浓度点。这些校准点有助于训练全连接层,提高模型的准确性。在实际使用过程中,在 AEN 配置固定的情况下,可以通过在大规模 GSA 部署中使用一小部分测试点对模型进行微调。仿真和实际测量结果表明,我们提出的测量模型具有很高的准确性,在 95% 的置信水平下,四种气体测量的相对误差置信区间低于 3%。此外,与传统方法相比,校准方案减少了测试点数量,降低了人力和设备成本。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A Novel Calibration Scheme of Gas Sensor Array for a More Accurate Measurement Model of Mixed Gases
Gas sensor arrays (GSAs) usually encounter challenges due to the cross-contamination of mixed gases, leading to reduced accuracy in measuring gas mixtures. However, with the advent of artificial intelligence, there is a promising avenue for addressing this issue effectively. In pursuit of more accurate mixed gas measurements, we proposed a measurement model leveraging neural networks. Our approach involved employing the encoder of an autoencoder network (AEN) to extract features from experimental data, while fully connected layers were utilized for predicting concentrations of mixed gases. To refine the neural network parameters, we employed a variational autoencoder to generate additional data resembling the distribution of experimental data. Subsequently, we designed a domain difference maximum entropy technique to identify optimal concentration points for the calibration data. These calibration points were instrumental in training the fully connected layers, enhancing the model’s accuracy. During practical usage, with the AEN configuration fixed, the model can be fine-tuned by using a small subset of test points across large-scale GSA deployments. Simulation and practical measurement results demonstrated the efficacy of our proposed measurement model, boasting high accuracy, with confidence intervals for relative errors of the four gas measurements below 3% at the 95% confidence level. Besides, the calibration scheme reduced the number of test points compared with traditional methods, reducing the cost of labor and equipment.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
ACS Sensors
ACS Sensors Chemical Engineering-Bioengineering
CiteScore
14.50
自引率
3.40%
发文量
372
期刊介绍: ACS Sensors is a peer-reviewed research journal that focuses on the dissemination of new and original knowledge in the field of sensor science, particularly those that selectively sense chemical or biological species or processes. The journal covers a broad range of topics, including but not limited to biosensors, chemical sensors, gas sensors, intracellular sensors, single molecule sensors, cell chips, and microfluidic devices. It aims to publish articles that address conceptual advances in sensing technology applicable to various types of analytes or application papers that report on the use of existing sensing concepts in new ways or for new analytes.
期刊最新文献
Development of an Attenuated Total Reflectance–Ultraviolet–Visible Probe for the Online Monitoring of Dark Solutions Making Sense of Citations Effects of Physiological-Scale Variation in Cations, pH, and Temperature on the Calibration of Electrochemical Aptamer-Based Sensors Target-Induced On-Protein Clustering of Metal Peptide Enables Low Overpotential Water Splitting for Early Detection of Non-Small-Cell Lung Cancer Self-Interference Digital Optofluidic Genotyping for Integrated and Automated Label-Free Pathogen Detection
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1