S. Potrykus , J. Nieznański , F. Kutt , F.J. Fernandez-Morales
{"title":"模拟外部负载变化对单个、串联和并联微生物燃料电池的影响。","authors":"S. Potrykus , J. Nieznański , F. Kutt , F.J. Fernandez-Morales","doi":"10.1016/j.biortech.2024.131761","DOIUrl":null,"url":null,"abstract":"<div><div>This paper presents a microbial fuel cell (MFC) model designed to analyze the effect of the external load on MFC performance. The model takes into account the voltage and the chemical oxygen demand (COD) dependence on the external load. The value of the model parameters were calibrated by means of the voltage relaxation method tests using a controlled load current. Laboratory measurements and MATLAB Simulink model computations were used to validate the proposed model. The tests results demonstrated that the proposed model accurately predicts the voltage and COD evolution during the batch cycle of the MFC. The root mean square error (RMSE) was used to assess the fitting goodness of the model. The RMSE of COD and voltage generation was in all the cases lower than 4%, predicting accurately the behaviour of single MFC as well as MFC connected in series or parallel.</div></div>","PeriodicalId":258,"journal":{"name":"Bioresource Technology","volume":"416 ","pages":"Article 131761"},"PeriodicalIF":9.7000,"publicationDate":"2024-11-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Modeling the effect of external load variations on single, serie and parallel connected microbial fuel cells\",\"authors\":\"S. Potrykus , J. Nieznański , F. Kutt , F.J. Fernandez-Morales\",\"doi\":\"10.1016/j.biortech.2024.131761\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>This paper presents a microbial fuel cell (MFC) model designed to analyze the effect of the external load on MFC performance. The model takes into account the voltage and the chemical oxygen demand (COD) dependence on the external load. The value of the model parameters were calibrated by means of the voltage relaxation method tests using a controlled load current. Laboratory measurements and MATLAB Simulink model computations were used to validate the proposed model. The tests results demonstrated that the proposed model accurately predicts the voltage and COD evolution during the batch cycle of the MFC. The root mean square error (RMSE) was used to assess the fitting goodness of the model. The RMSE of COD and voltage generation was in all the cases lower than 4%, predicting accurately the behaviour of single MFC as well as MFC connected in series or parallel.</div></div>\",\"PeriodicalId\":258,\"journal\":{\"name\":\"Bioresource Technology\",\"volume\":\"416 \",\"pages\":\"Article 131761\"},\"PeriodicalIF\":9.7000,\"publicationDate\":\"2024-11-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Bioresource Technology\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0960852424014652\",\"RegionNum\":1,\"RegionCategory\":\"环境科学与生态学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"AGRICULTURAL ENGINEERING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bioresource Technology","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0960852424014652","RegionNum":1,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"AGRICULTURAL ENGINEERING","Score":null,"Total":0}
Modeling the effect of external load variations on single, serie and parallel connected microbial fuel cells
This paper presents a microbial fuel cell (MFC) model designed to analyze the effect of the external load on MFC performance. The model takes into account the voltage and the chemical oxygen demand (COD) dependence on the external load. The value of the model parameters were calibrated by means of the voltage relaxation method tests using a controlled load current. Laboratory measurements and MATLAB Simulink model computations were used to validate the proposed model. The tests results demonstrated that the proposed model accurately predicts the voltage and COD evolution during the batch cycle of the MFC. The root mean square error (RMSE) was used to assess the fitting goodness of the model. The RMSE of COD and voltage generation was in all the cases lower than 4%, predicting accurately the behaviour of single MFC as well as MFC connected in series or parallel.
期刊介绍:
Bioresource Technology publishes original articles, review articles, case studies, and short communications covering the fundamentals, applications, and management of bioresource technology. The journal seeks to advance and disseminate knowledge across various areas related to biomass, biological waste treatment, bioenergy, biotransformations, bioresource systems analysis, and associated conversion or production technologies.
Topics include:
• Biofuels: liquid and gaseous biofuels production, modeling and economics
• Bioprocesses and bioproducts: biocatalysis and fermentations
• Biomass and feedstocks utilization: bioconversion of agro-industrial residues
• Environmental protection: biological waste treatment
• Thermochemical conversion of biomass: combustion, pyrolysis, gasification, catalysis.