Hao Wang, Dijie Yao, Yibing Luo, Bizhang Zhong, Yiqun Gu, Hongjing Wu, Bo-Ru Yang, Chunwei Li, Kai Tao, Jin Wu
{"title":"基于可穿戴应用的稳定封装有机水凝胶薄膜的超灵敏、快速响应和可拉伸温度微传感器","authors":"Hao Wang, Dijie Yao, Yibing Luo, Bizhang Zhong, Yiqun Gu, Hongjing Wu, Bo-Ru Yang, Chunwei Li, Kai Tao, Jin Wu","doi":"10.1021/acssensors.4c02677","DOIUrl":null,"url":null,"abstract":"<p><p>Ionic conductive hydrogel-based temperature sensors have emerged as promising candidates due to their good stretchability and biocompatibility. However, the unsatisfactory sensitivity, sluggish response/recovery speed, and poor environmental stability limit their applications for accurate long-term health monitoring and robot perception, especially in extreme environments. To address these concerns, here, the stretchable temperature sensors based on a double-side elastomer-encapsulated thin-film organohydrogel (DETO) architecture are proposed with impressive performance. It is found that the water-polyol binary solvent, organohydrogel film, and sandwiched device structure play important roles in the temperature sensing performance. By modifying the composition of binary solvent and thicknesses of organohydrogel and elastomer films, the DETO microsensors realize a thickness of only 380 μm, unprecedented temperature sensitivity (37.96%/°C), fast response time (6.01 s) and recovery time (10.53 s), wide detection range (25-95.7 °C), and good stretchability (40% strain), which are superior to those of conventional hydrogel-based sensors. Furthermore, the device displays good environmental stability with negligible dehydration and prolonged operation duration. With these attributes, the wearable sensor is exploited for the real-time monitoring of various physiological signals such as human skin temperature and respiration patterns as well as temperature perception for robots.</p>","PeriodicalId":24,"journal":{"name":"ACS Sensors","volume":null,"pages":null},"PeriodicalIF":8.2000,"publicationDate":"2024-11-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Ultrasensitive, Fast-Response, and Stretchable Temperature Microsensor Based on a Stable Encapsulated Organohydrogel Film for Wearable Applications.\",\"authors\":\"Hao Wang, Dijie Yao, Yibing Luo, Bizhang Zhong, Yiqun Gu, Hongjing Wu, Bo-Ru Yang, Chunwei Li, Kai Tao, Jin Wu\",\"doi\":\"10.1021/acssensors.4c02677\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Ionic conductive hydrogel-based temperature sensors have emerged as promising candidates due to their good stretchability and biocompatibility. However, the unsatisfactory sensitivity, sluggish response/recovery speed, and poor environmental stability limit their applications for accurate long-term health monitoring and robot perception, especially in extreme environments. To address these concerns, here, the stretchable temperature sensors based on a double-side elastomer-encapsulated thin-film organohydrogel (DETO) architecture are proposed with impressive performance. It is found that the water-polyol binary solvent, organohydrogel film, and sandwiched device structure play important roles in the temperature sensing performance. By modifying the composition of binary solvent and thicknesses of organohydrogel and elastomer films, the DETO microsensors realize a thickness of only 380 μm, unprecedented temperature sensitivity (37.96%/°C), fast response time (6.01 s) and recovery time (10.53 s), wide detection range (25-95.7 °C), and good stretchability (40% strain), which are superior to those of conventional hydrogel-based sensors. Furthermore, the device displays good environmental stability with negligible dehydration and prolonged operation duration. With these attributes, the wearable sensor is exploited for the real-time monitoring of various physiological signals such as human skin temperature and respiration patterns as well as temperature perception for robots.</p>\",\"PeriodicalId\":24,\"journal\":{\"name\":\"ACS Sensors\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":8.2000,\"publicationDate\":\"2024-11-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACS Sensors\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://doi.org/10.1021/acssensors.4c02677\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Sensors","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1021/acssensors.4c02677","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
Ultrasensitive, Fast-Response, and Stretchable Temperature Microsensor Based on a Stable Encapsulated Organohydrogel Film for Wearable Applications.
Ionic conductive hydrogel-based temperature sensors have emerged as promising candidates due to their good stretchability and biocompatibility. However, the unsatisfactory sensitivity, sluggish response/recovery speed, and poor environmental stability limit their applications for accurate long-term health monitoring and robot perception, especially in extreme environments. To address these concerns, here, the stretchable temperature sensors based on a double-side elastomer-encapsulated thin-film organohydrogel (DETO) architecture are proposed with impressive performance. It is found that the water-polyol binary solvent, organohydrogel film, and sandwiched device structure play important roles in the temperature sensing performance. By modifying the composition of binary solvent and thicknesses of organohydrogel and elastomer films, the DETO microsensors realize a thickness of only 380 μm, unprecedented temperature sensitivity (37.96%/°C), fast response time (6.01 s) and recovery time (10.53 s), wide detection range (25-95.7 °C), and good stretchability (40% strain), which are superior to those of conventional hydrogel-based sensors. Furthermore, the device displays good environmental stability with negligible dehydration and prolonged operation duration. With these attributes, the wearable sensor is exploited for the real-time monitoring of various physiological signals such as human skin temperature and respiration patterns as well as temperature perception for robots.
期刊介绍:
ACS Sensors is a peer-reviewed research journal that focuses on the dissemination of new and original knowledge in the field of sensor science, particularly those that selectively sense chemical or biological species or processes. The journal covers a broad range of topics, including but not limited to biosensors, chemical sensors, gas sensors, intracellular sensors, single molecule sensors, cell chips, and microfluidic devices. It aims to publish articles that address conceptual advances in sensing technology applicable to various types of analytes or application papers that report on the use of existing sensing concepts in new ways or for new analytes.