{"title":"如何在试验室中使用含有病毒的气溶胶验证基于紫外线-C 的空气净化器。","authors":"B Kramer, D Warschat, A Meepool, P Muranyi","doi":"10.1093/jambio/lxae287","DOIUrl":null,"url":null,"abstract":"<p><strong>Aims: </strong>UV-C based air cleaners may reduce the transmission of infectious diseases. However, microbiological validation is necessary to quantify their efficiency. In this study, the stability of aerosolized bacteriophages for validation purposes was investigated in a test room, before an UV-C based air cleaner was exemplarily evaluated regarding the inactivation of airborne bacteriophages.</p><p><strong>Methods and results: </strong>The bacteriophage Phi6 was selected as virus surrogate and aerosolized in a room of 30 m³ volume. The recovery of infectious bacteriophages was first analyzed under variation of the relative humidity (20-55% RH) and sampling time. The aerosol studies showed that a low humidity between 20% RH and 30% RH provides a high and stable recovery of bacteriophages Phi6 over 1 h. However, with increasing humidity, the number of infectious airborne bacteriophages Phi6 decreased significantly. At 50% RH, the recovery of Phi6 was 4 orders of magnitude lower compared to 20% RH. The validation of an UV-C based air cleaner was then demonstrated in the test room whereat the decline of infectious airborne bacteriophages was recorded over time. The non-enveloped bacteriophage MS2 was used as a reference. The validation results were significantly different for Phi6 when the humidity in the test room was either 40% RH or 30% RH whereas comparable results were obtained for MS2 at both humidities.</p><p><strong>Conclusion: </strong>A rising humidity in the test room caused a significant decline in the recovery of infectious airborne bacteriophages Phi6. The result of a quantitative validation of UV-C based air cleaners may therefore be affected by the respective humidity.</p>","PeriodicalId":15036,"journal":{"name":"Journal of Applied Microbiology","volume":" ","pages":""},"PeriodicalIF":3.2000,"publicationDate":"2024-11-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"How to validate UV-C based air cleaners using viruses containing aerosols in a test room.\",\"authors\":\"B Kramer, D Warschat, A Meepool, P Muranyi\",\"doi\":\"10.1093/jambio/lxae287\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Aims: </strong>UV-C based air cleaners may reduce the transmission of infectious diseases. However, microbiological validation is necessary to quantify their efficiency. In this study, the stability of aerosolized bacteriophages for validation purposes was investigated in a test room, before an UV-C based air cleaner was exemplarily evaluated regarding the inactivation of airborne bacteriophages.</p><p><strong>Methods and results: </strong>The bacteriophage Phi6 was selected as virus surrogate and aerosolized in a room of 30 m³ volume. The recovery of infectious bacteriophages was first analyzed under variation of the relative humidity (20-55% RH) and sampling time. The aerosol studies showed that a low humidity between 20% RH and 30% RH provides a high and stable recovery of bacteriophages Phi6 over 1 h. However, with increasing humidity, the number of infectious airborne bacteriophages Phi6 decreased significantly. At 50% RH, the recovery of Phi6 was 4 orders of magnitude lower compared to 20% RH. The validation of an UV-C based air cleaner was then demonstrated in the test room whereat the decline of infectious airborne bacteriophages was recorded over time. The non-enveloped bacteriophage MS2 was used as a reference. The validation results were significantly different for Phi6 when the humidity in the test room was either 40% RH or 30% RH whereas comparable results were obtained for MS2 at both humidities.</p><p><strong>Conclusion: </strong>A rising humidity in the test room caused a significant decline in the recovery of infectious airborne bacteriophages Phi6. The result of a quantitative validation of UV-C based air cleaners may therefore be affected by the respective humidity.</p>\",\"PeriodicalId\":15036,\"journal\":{\"name\":\"Journal of Applied Microbiology\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":3.2000,\"publicationDate\":\"2024-11-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Applied Microbiology\",\"FirstCategoryId\":\"99\",\"ListUrlMain\":\"https://doi.org/10.1093/jambio/lxae287\",\"RegionNum\":3,\"RegionCategory\":\"生物学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"BIOTECHNOLOGY & APPLIED MICROBIOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Applied Microbiology","FirstCategoryId":"99","ListUrlMain":"https://doi.org/10.1093/jambio/lxae287","RegionNum":3,"RegionCategory":"生物学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"BIOTECHNOLOGY & APPLIED MICROBIOLOGY","Score":null,"Total":0}
How to validate UV-C based air cleaners using viruses containing aerosols in a test room.
Aims: UV-C based air cleaners may reduce the transmission of infectious diseases. However, microbiological validation is necessary to quantify their efficiency. In this study, the stability of aerosolized bacteriophages for validation purposes was investigated in a test room, before an UV-C based air cleaner was exemplarily evaluated regarding the inactivation of airborne bacteriophages.
Methods and results: The bacteriophage Phi6 was selected as virus surrogate and aerosolized in a room of 30 m³ volume. The recovery of infectious bacteriophages was first analyzed under variation of the relative humidity (20-55% RH) and sampling time. The aerosol studies showed that a low humidity between 20% RH and 30% RH provides a high and stable recovery of bacteriophages Phi6 over 1 h. However, with increasing humidity, the number of infectious airborne bacteriophages Phi6 decreased significantly. At 50% RH, the recovery of Phi6 was 4 orders of magnitude lower compared to 20% RH. The validation of an UV-C based air cleaner was then demonstrated in the test room whereat the decline of infectious airborne bacteriophages was recorded over time. The non-enveloped bacteriophage MS2 was used as a reference. The validation results were significantly different for Phi6 when the humidity in the test room was either 40% RH or 30% RH whereas comparable results were obtained for MS2 at both humidities.
Conclusion: A rising humidity in the test room caused a significant decline in the recovery of infectious airborne bacteriophages Phi6. The result of a quantitative validation of UV-C based air cleaners may therefore be affected by the respective humidity.
期刊介绍:
Journal of & Letters in Applied Microbiology are two of the flagship research journals of the Society for Applied Microbiology (SfAM). For more than 75 years they have been publishing top quality research and reviews in the broad field of applied microbiology. The journals are provided to all SfAM members as well as having a global online readership totalling more than 500,000 downloads per year in more than 200 countries. Submitting authors can expect fast decision and publication times, averaging 33 days to first decision and 34 days from acceptance to online publication. There are no page charges.