新型不对称线性缝合器:猪模型的安全性测试和病理评估

IF 1.8 3区 医学 Q2 SURGERY Journal of Surgical Research Pub Date : 2024-11-09 DOI:10.1016/j.jss.2024.10.003
Yong Chae Jung MD , Wen Xue Piao MD , Ji-yeon Kim MD, PhD , Sang-il Lee MD, PhD , Ying Jie Cui MD , Yooyoung Chong MD , Hyun Jin Cho MD, PhD , Min-Woong Kang MD, PhD
{"title":"新型不对称线性缝合器:猪模型的安全性测试和病理评估","authors":"Yong Chae Jung MD ,&nbsp;Wen Xue Piao MD ,&nbsp;Ji-yeon Kim MD, PhD ,&nbsp;Sang-il Lee MD, PhD ,&nbsp;Ying Jie Cui MD ,&nbsp;Yooyoung Chong MD ,&nbsp;Hyun Jin Cho MD, PhD ,&nbsp;Min-Woong Kang MD, PhD","doi":"10.1016/j.jss.2024.10.003","DOIUrl":null,"url":null,"abstract":"<div><h3>Introduction</h3><div>Prognosis in patients undergoing resection for lung and gastrointestinal cancers may differ, depending on the microscopic involvement of surgical margins. Linear staplers, widely used for pulmonary or bowel resection, consist of three rows of fasteners on both sides of a resection line. Although multiple rows of fasteners ensure stump and specimen closure, specimen could compromise accurate pathological evaluation of the true surgical margin. We aimed to compare the novel asymmetrical linear stapler (NALS) with the symmetrical linear stapler (SLS) in a porcine model for stump security and accurate pathological evaluation.</div></div><div><h3>Materials and Methods</h3><div>We used the NALS with three and two rows of staples on the stump and specimen sides, respectively. We performed small bowel resection in a porcine model using the NALS and examined hemostasis of resection margin, tightness of stumps under a specific burst pressure, distances between the true resection margin and staple line, and pathology of the resection margin. An SLS was used as the control.</div></div><div><h3>Results</h3><div>No bleeding was observed at the tissue site after initial blotting of the stapler line with either stapler type. The staplers endured a burst pressure of 3.6 kPa for 15 s without leakage. The distance between the cutting edge and staple line for two rows was significantly greater than the distance between the cutting edge and the nearest staple line for three rows.</div></div><div><h3>Conclusions</h3><div>The NALS is safe and may be more accurate than is SLS for the pathological evaluation of true surgical margins.</div></div>","PeriodicalId":17030,"journal":{"name":"Journal of Surgical Research","volume":"304 ","pages":"Pages 58-66"},"PeriodicalIF":1.8000,"publicationDate":"2024-11-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Novel Asymmetrical Linear Stapler: Safety Test and Pathological Assessment in a Porcine Model\",\"authors\":\"Yong Chae Jung MD ,&nbsp;Wen Xue Piao MD ,&nbsp;Ji-yeon Kim MD, PhD ,&nbsp;Sang-il Lee MD, PhD ,&nbsp;Ying Jie Cui MD ,&nbsp;Yooyoung Chong MD ,&nbsp;Hyun Jin Cho MD, PhD ,&nbsp;Min-Woong Kang MD, PhD\",\"doi\":\"10.1016/j.jss.2024.10.003\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Introduction</h3><div>Prognosis in patients undergoing resection for lung and gastrointestinal cancers may differ, depending on the microscopic involvement of surgical margins. Linear staplers, widely used for pulmonary or bowel resection, consist of three rows of fasteners on both sides of a resection line. Although multiple rows of fasteners ensure stump and specimen closure, specimen could compromise accurate pathological evaluation of the true surgical margin. We aimed to compare the novel asymmetrical linear stapler (NALS) with the symmetrical linear stapler (SLS) in a porcine model for stump security and accurate pathological evaluation.</div></div><div><h3>Materials and Methods</h3><div>We used the NALS with three and two rows of staples on the stump and specimen sides, respectively. We performed small bowel resection in a porcine model using the NALS and examined hemostasis of resection margin, tightness of stumps under a specific burst pressure, distances between the true resection margin and staple line, and pathology of the resection margin. An SLS was used as the control.</div></div><div><h3>Results</h3><div>No bleeding was observed at the tissue site after initial blotting of the stapler line with either stapler type. The staplers endured a burst pressure of 3.6 kPa for 15 s without leakage. The distance between the cutting edge and staple line for two rows was significantly greater than the distance between the cutting edge and the nearest staple line for three rows.</div></div><div><h3>Conclusions</h3><div>The NALS is safe and may be more accurate than is SLS for the pathological evaluation of true surgical margins.</div></div>\",\"PeriodicalId\":17030,\"journal\":{\"name\":\"Journal of Surgical Research\",\"volume\":\"304 \",\"pages\":\"Pages 58-66\"},\"PeriodicalIF\":1.8000,\"publicationDate\":\"2024-11-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Surgical Research\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0022480424006541\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"SURGERY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Surgical Research","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0022480424006541","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0

摘要

导言:接受肺癌和胃肠癌切除术的患者的预后可能有所不同,这取决于手术边缘的显微受累情况。广泛用于肺部或肠道切除术的线性订书机由切除线两侧的三排紧固器组成。虽然多排紧固器可确保残端和标本的闭合,但标本可能会影响对真实手术边缘的准确病理评估。我们的目的是在猪模型中比较新型非对称线性订书机(NALS)和对称线性订书机(SLS),以确保残端安全和准确的病理评估:我们使用的 NALS 在残端和标本侧分别装有三排和两排订书钉。我们使用 NALS 在猪模型中进行了小肠切除术,并检查了切除边缘的止血情况、特定爆破压力下残端松紧度、真正切除边缘与订书线之间的距离以及切除边缘的病理情况。结果:结果:使用任何一种订书机,在订书机线初步印迹后,组织部位均未观察到出血。两种订书机都能承受 3.6 千帕的爆破压力 15 秒,且无泄漏。两行缝合线的切缘与缝合线之间的距离明显大于三行缝合线的切缘与最近缝合线之间的距离:结论:NALS 是安全的,在对真实手术边缘进行病理评估时可能比 SLS 更准确。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Novel Asymmetrical Linear Stapler: Safety Test and Pathological Assessment in a Porcine Model

Introduction

Prognosis in patients undergoing resection for lung and gastrointestinal cancers may differ, depending on the microscopic involvement of surgical margins. Linear staplers, widely used for pulmonary or bowel resection, consist of three rows of fasteners on both sides of a resection line. Although multiple rows of fasteners ensure stump and specimen closure, specimen could compromise accurate pathological evaluation of the true surgical margin. We aimed to compare the novel asymmetrical linear stapler (NALS) with the symmetrical linear stapler (SLS) in a porcine model for stump security and accurate pathological evaluation.

Materials and Methods

We used the NALS with three and two rows of staples on the stump and specimen sides, respectively. We performed small bowel resection in a porcine model using the NALS and examined hemostasis of resection margin, tightness of stumps under a specific burst pressure, distances between the true resection margin and staple line, and pathology of the resection margin. An SLS was used as the control.

Results

No bleeding was observed at the tissue site after initial blotting of the stapler line with either stapler type. The staplers endured a burst pressure of 3.6 kPa for 15 s without leakage. The distance between the cutting edge and staple line for two rows was significantly greater than the distance between the cutting edge and the nearest staple line for three rows.

Conclusions

The NALS is safe and may be more accurate than is SLS for the pathological evaluation of true surgical margins.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.90
自引率
4.50%
发文量
627
审稿时长
138 days
期刊介绍: The Journal of Surgical Research: Clinical and Laboratory Investigation publishes original articles concerned with clinical and laboratory investigations relevant to surgical practice and teaching. The journal emphasizes reports of clinical investigations or fundamental research bearing directly on surgical management that will be of general interest to a broad range of surgeons and surgical researchers. The articles presented need not have been the products of surgeons or of surgical laboratories. The Journal of Surgical Research also features review articles and special articles relating to educational, research, or social issues of interest to the academic surgical community.
期刊最新文献
Mortality in a Clostridium sordellii Case Series. Student and Attending Preceptor Perceptions of Longitudinal Clinic as a Surgical Education and Assessment Tool. Investigating the Burden of Traumatic Injuries and Access to Trauma Centers in Rural Riyadh. Examining Interpreter Services to Better Characterize Areas for Quality Improvement. Gender Disparity in Surgical Research: An Analysis of Authorship in Randomized Controlled Trials.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1