用于新生儿睡眠分类的近红外光谱技术

IF 3.4 3区 综合性期刊 Q2 CHEMISTRY, ANALYTICAL Sensors Pub Date : 2024-10-31 DOI:10.3390/s24217004
Naser Hakimi, Emad Arasteh, Maren Zahn, Jörn M Horschig, Willy N J M Colier, Jeroen Dudink, Thomas Alderliesten
{"title":"用于新生儿睡眠分类的近红外光谱技术","authors":"Naser Hakimi, Emad Arasteh, Maren Zahn, Jörn M Horschig, Willy N J M Colier, Jeroen Dudink, Thomas Alderliesten","doi":"10.3390/s24217004","DOIUrl":null,"url":null,"abstract":"<p><p>Sleep, notably active sleep (AS) and quiet sleep (QS), plays a pivotal role in the brain development and gradual maturation of (pre) term infants. Monitoring their sleep patterns is imperative, as it can serve as a tool in promoting neurological maturation and well-being, particularly important in preterm infants who are at an increased risk of immature brain development. An accurate classification of neonatal sleep states can contribute to optimizing treatments for high-risk infants, with respiratory rate (RR) and heart rate (HR) serving as key components in sleep assessment systems for neonates. Recent studies have demonstrated the feasibility of extracting both RR and HR using near-infrared spectroscopy (NIRS) in neonates. This study introduces a comprehensive sleep classification approach leveraging high-frequency NIRS signals recorded at a sampling rate of 100 Hz from a cohort of nine preterm infants admitted to a neonatal intensive care unit. Eight distinct features were extracted from the raw NIRS signals, including HR, RR, motion-related parameters, and proxies for neural activity. These features served as inputs for a deep convolutional neural network (CNN) model designed for the classification of AS and QS sleep states. The performance of the proposed CNN model was evaluated using two cross-validation approaches: ten-fold cross-validation of data pooling and five-fold cross-validation, where each fold contains two independently recorded NIRS data. The accuracy, balanced accuracy, F1-score, Kappa, and AUC-ROC (Area Under the Curve of the Receiver Operating Characteristic) were employed to assess the classifier performance. In addition, comparative analyses against six benchmark classifiers, comprising K-Nearest Neighbors, Naive Bayes, Support Vector Machines, Random Forest (RF), AdaBoost, and XGBoost (XGB), were conducted. Our results reveal the CNN model's superior performance, achieving an average accuracy of 88%, a balanced accuracy of 94%, an F1-score of 91%, Kappa of 95%, and an AUC-ROC of 96% in data pooling cross-validation. Furthermore, in both cross-validation methods, RF and XGB demonstrated accuracy levels closely comparable to the CNN classifier. These findings underscore the feasibility of leveraging high-frequency NIRS data, coupled with NIRS-based HR and RR extraction, for assessing sleep states in neonates, even in an intensive care setting. The user-friendliness, portability, and reduced sensor complexity of the approach suggest its potential applications in various less-demanding settings. This research thus presents a promising avenue for advancing neonatal sleep assessment and its implications for infant health and development.</p>","PeriodicalId":21698,"journal":{"name":"Sensors","volume":"24 21","pages":""},"PeriodicalIF":3.4000,"publicationDate":"2024-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11548375/pdf/","citationCount":"0","resultStr":"{\"title\":\"Near-Infrared Spectroscopy for Neonatal Sleep Classification.\",\"authors\":\"Naser Hakimi, Emad Arasteh, Maren Zahn, Jörn M Horschig, Willy N J M Colier, Jeroen Dudink, Thomas Alderliesten\",\"doi\":\"10.3390/s24217004\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Sleep, notably active sleep (AS) and quiet sleep (QS), plays a pivotal role in the brain development and gradual maturation of (pre) term infants. Monitoring their sleep patterns is imperative, as it can serve as a tool in promoting neurological maturation and well-being, particularly important in preterm infants who are at an increased risk of immature brain development. An accurate classification of neonatal sleep states can contribute to optimizing treatments for high-risk infants, with respiratory rate (RR) and heart rate (HR) serving as key components in sleep assessment systems for neonates. Recent studies have demonstrated the feasibility of extracting both RR and HR using near-infrared spectroscopy (NIRS) in neonates. This study introduces a comprehensive sleep classification approach leveraging high-frequency NIRS signals recorded at a sampling rate of 100 Hz from a cohort of nine preterm infants admitted to a neonatal intensive care unit. Eight distinct features were extracted from the raw NIRS signals, including HR, RR, motion-related parameters, and proxies for neural activity. These features served as inputs for a deep convolutional neural network (CNN) model designed for the classification of AS and QS sleep states. The performance of the proposed CNN model was evaluated using two cross-validation approaches: ten-fold cross-validation of data pooling and five-fold cross-validation, where each fold contains two independently recorded NIRS data. The accuracy, balanced accuracy, F1-score, Kappa, and AUC-ROC (Area Under the Curve of the Receiver Operating Characteristic) were employed to assess the classifier performance. In addition, comparative analyses against six benchmark classifiers, comprising K-Nearest Neighbors, Naive Bayes, Support Vector Machines, Random Forest (RF), AdaBoost, and XGBoost (XGB), were conducted. Our results reveal the CNN model's superior performance, achieving an average accuracy of 88%, a balanced accuracy of 94%, an F1-score of 91%, Kappa of 95%, and an AUC-ROC of 96% in data pooling cross-validation. Furthermore, in both cross-validation methods, RF and XGB demonstrated accuracy levels closely comparable to the CNN classifier. These findings underscore the feasibility of leveraging high-frequency NIRS data, coupled with NIRS-based HR and RR extraction, for assessing sleep states in neonates, even in an intensive care setting. The user-friendliness, portability, and reduced sensor complexity of the approach suggest its potential applications in various less-demanding settings. This research thus presents a promising avenue for advancing neonatal sleep assessment and its implications for infant health and development.</p>\",\"PeriodicalId\":21698,\"journal\":{\"name\":\"Sensors\",\"volume\":\"24 21\",\"pages\":\"\"},\"PeriodicalIF\":3.4000,\"publicationDate\":\"2024-10-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11548375/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Sensors\",\"FirstCategoryId\":\"103\",\"ListUrlMain\":\"https://doi.org/10.3390/s24217004\",\"RegionNum\":3,\"RegionCategory\":\"综合性期刊\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sensors","FirstCategoryId":"103","ListUrlMain":"https://doi.org/10.3390/s24217004","RegionNum":3,"RegionCategory":"综合性期刊","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

睡眠,尤其是活跃睡眠(AS)和安静睡眠(QS),对(早产)婴儿的大脑发育和逐渐成熟起着至关重要的作用。监测他们的睡眠模式势在必行,因为它可以作为促进神经系统成熟和健康的工具,这对早产儿尤为重要,因为早产儿大脑发育不成熟的风险较高。新生儿睡眠状态的准确分类有助于优化对高风险婴儿的治疗,呼吸频率(RR)和心率(HR)是新生儿睡眠评估系统的关键组成部分。最近的研究表明,使用近红外光谱(NIRS)提取新生儿的 RR 和 HR 是可行的。本研究介绍了一种综合睡眠分类方法,该方法利用了新生儿重症监护室收治的九名早产儿以 100 Hz 采样率记录的高频 NIRS 信号。从原始近红外光谱信号中提取了八个不同的特征,包括心率、呼吸频率、运动相关参数和神经活动代理。这些特征可作为深度卷积神经网络(CNN)模型的输入,用于对 AS 和 QS 睡眠状态进行分类。使用两种交叉验证方法评估了所提出的 CNN 模型的性能:数据池十倍交叉验证和五倍交叉验证,其中每一倍包含两个独立记录的 NIRS 数据。采用准确率、平衡准确率、F1 分数、Kappa 和 AUC-ROC(接收者操作特征曲线下面积)来评估分类器的性能。此外,还与 K-Nearest Neighbors、Naive Bayes、支持向量机、Random Forest (RF)、AdaBoost 和 XGBoost (XGB) 等六种基准分类器进行了比较分析。结果显示,CNN 模型性能优越,在数据池交叉验证中取得了 88% 的平均准确率、94% 的均衡准确率、91% 的 F1 分数、95% 的 Kappa 分数和 96% 的 AUC-ROC 分数。此外,在两种交叉验证方法中,RF 和 XGB 的准确率水平都与 CNN 分类器不相上下。这些发现强调了利用高频 NIRS 数据以及基于 NIRS 的 HR 和 RR 提取来评估新生儿睡眠状态的可行性,即使是在重症监护环境中也是如此。该方法具有用户友好性、便携性和降低传感器复杂性的特点,有望应用于各种要求较低的环境中。因此,这项研究为推进新生儿睡眠评估及其对婴儿健康和发育的影响提供了一个前景广阔的途径。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Near-Infrared Spectroscopy for Neonatal Sleep Classification.

Sleep, notably active sleep (AS) and quiet sleep (QS), plays a pivotal role in the brain development and gradual maturation of (pre) term infants. Monitoring their sleep patterns is imperative, as it can serve as a tool in promoting neurological maturation and well-being, particularly important in preterm infants who are at an increased risk of immature brain development. An accurate classification of neonatal sleep states can contribute to optimizing treatments for high-risk infants, with respiratory rate (RR) and heart rate (HR) serving as key components in sleep assessment systems for neonates. Recent studies have demonstrated the feasibility of extracting both RR and HR using near-infrared spectroscopy (NIRS) in neonates. This study introduces a comprehensive sleep classification approach leveraging high-frequency NIRS signals recorded at a sampling rate of 100 Hz from a cohort of nine preterm infants admitted to a neonatal intensive care unit. Eight distinct features were extracted from the raw NIRS signals, including HR, RR, motion-related parameters, and proxies for neural activity. These features served as inputs for a deep convolutional neural network (CNN) model designed for the classification of AS and QS sleep states. The performance of the proposed CNN model was evaluated using two cross-validation approaches: ten-fold cross-validation of data pooling and five-fold cross-validation, where each fold contains two independently recorded NIRS data. The accuracy, balanced accuracy, F1-score, Kappa, and AUC-ROC (Area Under the Curve of the Receiver Operating Characteristic) were employed to assess the classifier performance. In addition, comparative analyses against six benchmark classifiers, comprising K-Nearest Neighbors, Naive Bayes, Support Vector Machines, Random Forest (RF), AdaBoost, and XGBoost (XGB), were conducted. Our results reveal the CNN model's superior performance, achieving an average accuracy of 88%, a balanced accuracy of 94%, an F1-score of 91%, Kappa of 95%, and an AUC-ROC of 96% in data pooling cross-validation. Furthermore, in both cross-validation methods, RF and XGB demonstrated accuracy levels closely comparable to the CNN classifier. These findings underscore the feasibility of leveraging high-frequency NIRS data, coupled with NIRS-based HR and RR extraction, for assessing sleep states in neonates, even in an intensive care setting. The user-friendliness, portability, and reduced sensor complexity of the approach suggest its potential applications in various less-demanding settings. This research thus presents a promising avenue for advancing neonatal sleep assessment and its implications for infant health and development.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Sensors
Sensors 工程技术-电化学
CiteScore
7.30
自引率
12.80%
发文量
8430
审稿时长
1.7 months
期刊介绍: Sensors (ISSN 1424-8220) provides an advanced forum for the science and technology of sensors and biosensors. It publishes reviews (including comprehensive reviews on the complete sensors products), regular research papers and short notes. Our aim is to encourage scientists to publish their experimental and theoretical results in as much detail as possible. There is no restriction on the length of the papers. The full experimental details must be provided so that the results can be reproduced.
期刊最新文献
A Review of Cutting-Edge Sensor Technologies for Improved Flood Monitoring and Damage Assessment. Optimizing the Agricultural Internet of Things (IoT) with Edge Computing and Low-Altitude Platform Stations. A Study of the Effect of Temperature on the Capacitance Characteristics of a Metal-μhemisphere Resonant Gyroscope. Evaluating Alternative Registration Planes in Imageless, Computer-Assisted Navigation Systems for Direct Anterior Total Hip Arthroplasty. Passive and Active Exoskeleton Solutions: Sensors, Actuators, Applications, and Recent Trends.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1