J Tye, O Solgaard, R J England, J V Trapp, A Fielding, C P Brown
{"title":"超短电子脉冲增强活性氧的产生。","authors":"J Tye, O Solgaard, R J England, J V Trapp, A Fielding, C P Brown","doi":"10.1098/rsos.240898","DOIUrl":null,"url":null,"abstract":"<p><p>The development of laser-driven accelerators-on-chip has provided an opportunity to miniaturize devices for electron radiotherapy delivery. Laser-driven accelerators produce highly time-compressed electron pulses, on the 100 fs to 1 ps scale. This delivers electrons at high peak power yet low average beam current compared with conventional delivery devices, which generate pulses of approximately 3 µs. The biophysical effects of this time structure, however, are unclear. Here, we use a Monte Carlo simulation approach to explore the effects of the electron beam time structure on the production of reactive oxygen species (ROS) in water. Our results show a power law increase in the generation of hydroxyl ions per deposited electron with decreasing pulse length over the pulse length range of 10 µs to 100 fs. Similar trends were observed for hydrogen peroxide, superoxide, hydroperoxyl, hydronium and solvated electrons. In practical terms, this indicates a fourfold increase in the efficiency of free radical production for sub-picosecond pulses, relative to that of conventional microsecond pulses, for the same number of deposited electrons.</p>","PeriodicalId":21525,"journal":{"name":"Royal Society Open Science","volume":"11 11","pages":"240898"},"PeriodicalIF":2.9000,"publicationDate":"2024-11-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11557238/pdf/","citationCount":"0","resultStr":"{\"title\":\"Enhancement of reactive oxygen species production by ultra-short electron pulses.\",\"authors\":\"J Tye, O Solgaard, R J England, J V Trapp, A Fielding, C P Brown\",\"doi\":\"10.1098/rsos.240898\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The development of laser-driven accelerators-on-chip has provided an opportunity to miniaturize devices for electron radiotherapy delivery. Laser-driven accelerators produce highly time-compressed electron pulses, on the 100 fs to 1 ps scale. This delivers electrons at high peak power yet low average beam current compared with conventional delivery devices, which generate pulses of approximately 3 µs. The biophysical effects of this time structure, however, are unclear. Here, we use a Monte Carlo simulation approach to explore the effects of the electron beam time structure on the production of reactive oxygen species (ROS) in water. Our results show a power law increase in the generation of hydroxyl ions per deposited electron with decreasing pulse length over the pulse length range of 10 µs to 100 fs. Similar trends were observed for hydrogen peroxide, superoxide, hydroperoxyl, hydronium and solvated electrons. In practical terms, this indicates a fourfold increase in the efficiency of free radical production for sub-picosecond pulses, relative to that of conventional microsecond pulses, for the same number of deposited electrons.</p>\",\"PeriodicalId\":21525,\"journal\":{\"name\":\"Royal Society Open Science\",\"volume\":\"11 11\",\"pages\":\"240898\"},\"PeriodicalIF\":2.9000,\"publicationDate\":\"2024-11-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11557238/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Royal Society Open Science\",\"FirstCategoryId\":\"103\",\"ListUrlMain\":\"https://doi.org/10.1098/rsos.240898\",\"RegionNum\":3,\"RegionCategory\":\"综合性期刊\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/11/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q1\",\"JCRName\":\"MULTIDISCIPLINARY SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Royal Society Open Science","FirstCategoryId":"103","ListUrlMain":"https://doi.org/10.1098/rsos.240898","RegionNum":3,"RegionCategory":"综合性期刊","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/11/1 0:00:00","PubModel":"eCollection","JCR":"Q1","JCRName":"MULTIDISCIPLINARY SCIENCES","Score":null,"Total":0}
Enhancement of reactive oxygen species production by ultra-short electron pulses.
The development of laser-driven accelerators-on-chip has provided an opportunity to miniaturize devices for electron radiotherapy delivery. Laser-driven accelerators produce highly time-compressed electron pulses, on the 100 fs to 1 ps scale. This delivers electrons at high peak power yet low average beam current compared with conventional delivery devices, which generate pulses of approximately 3 µs. The biophysical effects of this time structure, however, are unclear. Here, we use a Monte Carlo simulation approach to explore the effects of the electron beam time structure on the production of reactive oxygen species (ROS) in water. Our results show a power law increase in the generation of hydroxyl ions per deposited electron with decreasing pulse length over the pulse length range of 10 µs to 100 fs. Similar trends were observed for hydrogen peroxide, superoxide, hydroperoxyl, hydronium and solvated electrons. In practical terms, this indicates a fourfold increase in the efficiency of free radical production for sub-picosecond pulses, relative to that of conventional microsecond pulses, for the same number of deposited electrons.
期刊介绍:
Royal Society Open Science is a new open journal publishing high-quality original research across the entire range of science on the basis of objective peer-review.
The journal covers the entire range of science and mathematics and will allow the Society to publish all the high-quality work it receives without the usual restrictions on scope, length or impact.