{"title":"非线性传感器的二维渐进多项式分段校准法","authors":"Jae-Lim Lee, Dong-Sun Kim","doi":"10.3390/s24217058","DOIUrl":null,"url":null,"abstract":"<p><p>Nonlinearity in sensor measurements reduces the sensor's accuracy. Therefore, accurate calibration is necessary for reliable sensor operation. This study proposes a segmented calibration method that divides the input range into multiple sections and calculates the optimized calibration functions for each one. This approach reduces the overall error rate and improves the calibration accuracy by isolating distinctive regions. The modified progressive polynomial calibration technique is used to calculate the calibration function. This algorithm addresses the computational complexity, allowing for reduced polynomial degrees and improving the accuracy. The segmented calibration method achieves a significantly lower error rate of 0.000006% compared to the original single calibration method, which has an error rate of 0.0823%, when using the same six calibration points and a fifth-degree polynomial function. This method maintains improved accuracy with fewer calibration points, and its ability to reduce the computational complexity and calculation time while using lower polynomial degrees is confirmed. Additionally, it can be extended to two dimensions to reduce the errors caused by cross-sensitivity. The results from a two-dimensional simulation show a reduction in the error rate ranging from 15.84% to 2.07% in an 8-bit signed fixed-point system. These results indicate that the segmented calibration method is an effective and scalable solution for various typical sensors.</p>","PeriodicalId":21698,"journal":{"name":"Sensors","volume":"24 21","pages":""},"PeriodicalIF":3.4000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11548594/pdf/","citationCount":"0","resultStr":"{\"title\":\"Segmented Two-Dimensional Progressive Polynomial Calibration Method for Nonlinear Sensors.\",\"authors\":\"Jae-Lim Lee, Dong-Sun Kim\",\"doi\":\"10.3390/s24217058\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Nonlinearity in sensor measurements reduces the sensor's accuracy. Therefore, accurate calibration is necessary for reliable sensor operation. This study proposes a segmented calibration method that divides the input range into multiple sections and calculates the optimized calibration functions for each one. This approach reduces the overall error rate and improves the calibration accuracy by isolating distinctive regions. The modified progressive polynomial calibration technique is used to calculate the calibration function. This algorithm addresses the computational complexity, allowing for reduced polynomial degrees and improving the accuracy. The segmented calibration method achieves a significantly lower error rate of 0.000006% compared to the original single calibration method, which has an error rate of 0.0823%, when using the same six calibration points and a fifth-degree polynomial function. This method maintains improved accuracy with fewer calibration points, and its ability to reduce the computational complexity and calculation time while using lower polynomial degrees is confirmed. Additionally, it can be extended to two dimensions to reduce the errors caused by cross-sensitivity. The results from a two-dimensional simulation show a reduction in the error rate ranging from 15.84% to 2.07% in an 8-bit signed fixed-point system. These results indicate that the segmented calibration method is an effective and scalable solution for various typical sensors.</p>\",\"PeriodicalId\":21698,\"journal\":{\"name\":\"Sensors\",\"volume\":\"24 21\",\"pages\":\"\"},\"PeriodicalIF\":3.4000,\"publicationDate\":\"2024-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11548594/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Sensors\",\"FirstCategoryId\":\"103\",\"ListUrlMain\":\"https://doi.org/10.3390/s24217058\",\"RegionNum\":3,\"RegionCategory\":\"综合性期刊\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sensors","FirstCategoryId":"103","ListUrlMain":"https://doi.org/10.3390/s24217058","RegionNum":3,"RegionCategory":"综合性期刊","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
Segmented Two-Dimensional Progressive Polynomial Calibration Method for Nonlinear Sensors.
Nonlinearity in sensor measurements reduces the sensor's accuracy. Therefore, accurate calibration is necessary for reliable sensor operation. This study proposes a segmented calibration method that divides the input range into multiple sections and calculates the optimized calibration functions for each one. This approach reduces the overall error rate and improves the calibration accuracy by isolating distinctive regions. The modified progressive polynomial calibration technique is used to calculate the calibration function. This algorithm addresses the computational complexity, allowing for reduced polynomial degrees and improving the accuracy. The segmented calibration method achieves a significantly lower error rate of 0.000006% compared to the original single calibration method, which has an error rate of 0.0823%, when using the same six calibration points and a fifth-degree polynomial function. This method maintains improved accuracy with fewer calibration points, and its ability to reduce the computational complexity and calculation time while using lower polynomial degrees is confirmed. Additionally, it can be extended to two dimensions to reduce the errors caused by cross-sensitivity. The results from a two-dimensional simulation show a reduction in the error rate ranging from 15.84% to 2.07% in an 8-bit signed fixed-point system. These results indicate that the segmented calibration method is an effective and scalable solution for various typical sensors.
期刊介绍:
Sensors (ISSN 1424-8220) provides an advanced forum for the science and technology of sensors and biosensors. It publishes reviews (including comprehensive reviews on the complete sensors products), regular research papers and short notes. Our aim is to encourage scientists to publish their experimental and theoretical results in as much detail as possible. There is no restriction on the length of the papers. The full experimental details must be provided so that the results can be reproduced.