预制金属冠与氧化锆冠对磁共振图像诊断质量的影响。

IF 2.3 Q2 DENTISTRY, ORAL SURGERY & MEDICINE European Archives of Paediatric Dentistry Pub Date : 2024-11-13 DOI:10.1007/s40368-024-00971-x
O Dalzell, P Haghighi, J Ho, T Rayner, L Vidarsson, G A Garisto
{"title":"预制金属冠与氧化锆冠对磁共振图像诊断质量的影响。","authors":"O Dalzell, P Haghighi, J Ho, T Rayner, L Vidarsson, G A Garisto","doi":"10.1007/s40368-024-00971-x","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The purpose of this study was to investigate and compare in vitro the influence of preformed metal crowns (PMC) versus zirconia crowns (ZC) on the extent of artifact formation and the diagnostic quality of magnetic resonance imaging (MRI).</p><p><strong>Methods: </strong>Standard crown tooth preparations were performed on Typodont models. PMC and ZC were cemented on all primary molar teeth (n = 8) of the respective models. MRI scans were taken for the Typodont alone (control), PMC, and ZC, using a 3 T MRI machine and common MRI sequences. The diameter of image distortion was measured around the dental materials. Data was analyzed using a mixed model analysis.</p><p><strong>Results: </strong>The average artifact size for PMC was 54.9 mm (range 19.6-110.7 mm) and 12.8 mm (range 5.5-20.7 mm) for ZC. The artifact size was associated with the MRI pulse sequence and dental material, with PMC showing larger artifact diameters than ZC for all MRI sequences (p < 0.001). The control had sensitive sequences for AxT2* and DWI sequences with MRI artifacts of 11.4 mm and 10.7 mm, respectively.</p><p><strong>Conclusions: </strong>It is important that dentists are aware of the potential of dental materials to cause unfavourable MRI artifacts. When areas of the brain requiring MRI preclude the use of PMC, ZC may be considered as an alternative to extractions. Further clinical studies are required to evaluate the impact of dental materials on the image quality of MR scans in vivo.</p>","PeriodicalId":47603,"journal":{"name":"European Archives of Paediatric Dentistry","volume":" ","pages":""},"PeriodicalIF":2.3000,"publicationDate":"2024-11-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The influence of preformed metal crowns versus zirconia crowns on the diagnostic quality of magnetic resonance images.\",\"authors\":\"O Dalzell, P Haghighi, J Ho, T Rayner, L Vidarsson, G A Garisto\",\"doi\":\"10.1007/s40368-024-00971-x\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>The purpose of this study was to investigate and compare in vitro the influence of preformed metal crowns (PMC) versus zirconia crowns (ZC) on the extent of artifact formation and the diagnostic quality of magnetic resonance imaging (MRI).</p><p><strong>Methods: </strong>Standard crown tooth preparations were performed on Typodont models. PMC and ZC were cemented on all primary molar teeth (n = 8) of the respective models. MRI scans were taken for the Typodont alone (control), PMC, and ZC, using a 3 T MRI machine and common MRI sequences. The diameter of image distortion was measured around the dental materials. Data was analyzed using a mixed model analysis.</p><p><strong>Results: </strong>The average artifact size for PMC was 54.9 mm (range 19.6-110.7 mm) and 12.8 mm (range 5.5-20.7 mm) for ZC. The artifact size was associated with the MRI pulse sequence and dental material, with PMC showing larger artifact diameters than ZC for all MRI sequences (p < 0.001). The control had sensitive sequences for AxT2* and DWI sequences with MRI artifacts of 11.4 mm and 10.7 mm, respectively.</p><p><strong>Conclusions: </strong>It is important that dentists are aware of the potential of dental materials to cause unfavourable MRI artifacts. When areas of the brain requiring MRI preclude the use of PMC, ZC may be considered as an alternative to extractions. Further clinical studies are required to evaluate the impact of dental materials on the image quality of MR scans in vivo.</p>\",\"PeriodicalId\":47603,\"journal\":{\"name\":\"European Archives of Paediatric Dentistry\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":2.3000,\"publicationDate\":\"2024-11-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"European Archives of Paediatric Dentistry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1007/s40368-024-00971-x\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Archives of Paediatric Dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s40368-024-00971-x","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

目的:本研究的目的是在体外研究和比较预成金属冠(PMC)和氧化锆冠(ZC)对伪影形成程度和磁共振成像(MRI)诊断质量的影响:方法:在Typodont模型上进行标准牙冠牙体预备。在各自模型的所有基磨牙(n = 8)上粘接 PMC 和 ZC。使用 3 T 核磁共振成像仪和普通核磁共振成像序列对单独的 Typodont(对照组)、PMC 和 ZC 进行核磁共振成像扫描。测量了牙科材料周围的图像变形直径。采用混合模型分析法对数据进行分析:结果:PMC 的平均伪影尺寸为 54.9 毫米(范围为 19.6-110.7 毫米),ZC 的平均伪影尺寸为 12.8 毫米(范围为 5.5-20.7 毫米)。伪影大小与磁共振成像脉冲序列和牙科材料有关,在所有磁共振成像序列中,PMC的伪影直径都比ZC大(p 结论:PMC的伪影直径比ZC的大:牙科医生必须意识到牙科材料可能会造成不利的磁共振成像伪影。当需要磁共振成像的脑部区域无法使用 PMC 时,可以考虑使用 ZC 作为拔牙的替代方法。还需要进一步的临床研究来评估牙科材料对体内磁共振扫描图像质量的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
The influence of preformed metal crowns versus zirconia crowns on the diagnostic quality of magnetic resonance images.

Purpose: The purpose of this study was to investigate and compare in vitro the influence of preformed metal crowns (PMC) versus zirconia crowns (ZC) on the extent of artifact formation and the diagnostic quality of magnetic resonance imaging (MRI).

Methods: Standard crown tooth preparations were performed on Typodont models. PMC and ZC were cemented on all primary molar teeth (n = 8) of the respective models. MRI scans were taken for the Typodont alone (control), PMC, and ZC, using a 3 T MRI machine and common MRI sequences. The diameter of image distortion was measured around the dental materials. Data was analyzed using a mixed model analysis.

Results: The average artifact size for PMC was 54.9 mm (range 19.6-110.7 mm) and 12.8 mm (range 5.5-20.7 mm) for ZC. The artifact size was associated with the MRI pulse sequence and dental material, with PMC showing larger artifact diameters than ZC for all MRI sequences (p < 0.001). The control had sensitive sequences for AxT2* and DWI sequences with MRI artifacts of 11.4 mm and 10.7 mm, respectively.

Conclusions: It is important that dentists are aware of the potential of dental materials to cause unfavourable MRI artifacts. When areas of the brain requiring MRI preclude the use of PMC, ZC may be considered as an alternative to extractions. Further clinical studies are required to evaluate the impact of dental materials on the image quality of MR scans in vivo.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
European Archives of Paediatric Dentistry
European Archives of Paediatric Dentistry DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
4.40
自引率
9.10%
发文量
81
期刊介绍: The aim and scope of European Archives of Paediatric Dentistry (EAPD) is to promote research in all aspects of dentistry for children, including interceptive orthodontics and studies on children and young adults with special needs. The EAPD focuses on the publication and critical evaluation of clinical and basic science research related to children. The EAPD will consider clinical case series reports, followed by the relevant literature review, only where there are new and important findings of interest to Paediatric Dentistry and where details of techniques or treatment carried out and the success of such approaches are given.
期刊最新文献
Obesity/overweight and dental caries experience in children and adolescents: an umbrella review. Early detection of MIH in children by using artificial intelligence. WHO essential medicines for dentistry: a focus on patients with special care needs. A comparison of conventional sodium fluoride varnish and nano-sodium fluoride varnish regarding enamel microhardness of deciduous teeth: an in-vitro study. Restricted tongue mobility and ankyloglossia in 6-8-year-old Vietnamese school children: prevalence and association with tongue strength and endurance.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1