{"title":"韩国人工泪液中的微塑料污染:直接接触眼部的可能性。","authors":"Yun-Hee Choi, Nayoon Park, Juyang Kim, Seul-Ah Park, Jaehak Jung, Jong Suk Song, Yoon-Hyeong Choi, Dong Hyun Kim","doi":"10.1016/j.clae.2024.102325","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To investigate microplastics (MP) contamination in artificial tear (AT) products.</p><p><strong>Method: </strong>Five hyaluronic acid ATs (two multi-use and three disposable ATs) were used to gauge MP levels in three scenarios: 1) initial drop and remaining liquid after opening the lid upward; 2) remaining liquid after opening the lid downward and discarding two drops; and 3) remaining liquid after opening the lid downward and discarding half of it. Raman spectroscopy was used to identify the quantity, morphological characteristics, and composition of MPs. Scanning electron microscopy/energy dispersive spectroscopy was used to examine the surface traits and elements of MPs and ATs.</p><p><strong>Results: </strong>MPs were detected in 4 out of 5 ATs in the initial drops, containing 0.50 ± 0.65 particles/30 mL, whereas the remaining solution had 0.75 ± 0.72 particles/30 mL. After discarding two drops, 0.14 ± 0.35 particles/30 mL were present in the remaining solution. No MPs were detected after discarding half drops. Most MPs were transparent (95 %), irregular fragments (55 %) sized 10-20 μm (35 %), and made of polyethylene (95 %). If patients use the first drops of ATs four times a day for a year, individuals can be exposed to 730.0 particles. This exposure can be reduced to 204.4 particles by discarding the first two drops before use.</p><p><strong>Conclusion: </strong>MPs are observed in commercially available ATs, and human eyes may be directly exposed to MPs through the use of ATs.</p>","PeriodicalId":49087,"journal":{"name":"Contact Lens & Anterior Eye","volume":" ","pages":"102325"},"PeriodicalIF":4.1000,"publicationDate":"2024-11-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Microplastic contamination in artificial tears in South Korea: Potential for direct ocular exposure.\",\"authors\":\"Yun-Hee Choi, Nayoon Park, Juyang Kim, Seul-Ah Park, Jaehak Jung, Jong Suk Song, Yoon-Hyeong Choi, Dong Hyun Kim\",\"doi\":\"10.1016/j.clae.2024.102325\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To investigate microplastics (MP) contamination in artificial tear (AT) products.</p><p><strong>Method: </strong>Five hyaluronic acid ATs (two multi-use and three disposable ATs) were used to gauge MP levels in three scenarios: 1) initial drop and remaining liquid after opening the lid upward; 2) remaining liquid after opening the lid downward and discarding two drops; and 3) remaining liquid after opening the lid downward and discarding half of it. Raman spectroscopy was used to identify the quantity, morphological characteristics, and composition of MPs. Scanning electron microscopy/energy dispersive spectroscopy was used to examine the surface traits and elements of MPs and ATs.</p><p><strong>Results: </strong>MPs were detected in 4 out of 5 ATs in the initial drops, containing 0.50 ± 0.65 particles/30 mL, whereas the remaining solution had 0.75 ± 0.72 particles/30 mL. After discarding two drops, 0.14 ± 0.35 particles/30 mL were present in the remaining solution. No MPs were detected after discarding half drops. Most MPs were transparent (95 %), irregular fragments (55 %) sized 10-20 μm (35 %), and made of polyethylene (95 %). If patients use the first drops of ATs four times a day for a year, individuals can be exposed to 730.0 particles. This exposure can be reduced to 204.4 particles by discarding the first two drops before use.</p><p><strong>Conclusion: </strong>MPs are observed in commercially available ATs, and human eyes may be directly exposed to MPs through the use of ATs.</p>\",\"PeriodicalId\":49087,\"journal\":{\"name\":\"Contact Lens & Anterior Eye\",\"volume\":\" \",\"pages\":\"102325\"},\"PeriodicalIF\":4.1000,\"publicationDate\":\"2024-11-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Contact Lens & Anterior Eye\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1016/j.clae.2024.102325\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Contact Lens & Anterior Eye","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.clae.2024.102325","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:研究人工泪液(AT)产品中的微塑料(MP)污染:使用五种透明质酸人工泪液(两种多用途人工泪液和三种一次性人工泪液)在三种情况下测量MP含量:1)初始滴液和向上打开盖子后的剩余液体;2)向下打开盖子并丢弃两滴后的剩余液体;3)向下打开盖子并丢弃一半后的剩余液体。拉曼光谱用于鉴定 MPs 的数量、形态特征和成分。扫描电子显微镜/能量色散光谱法用于检测 MPs 和 ATs 的表面特征和元素:结果:在最初滴入的 5 滴 AT 溶液中,有 4 滴检测到了 MP,每 30 mL 溶液中含有 0.50 ± 0.65 个颗粒,而剩余溶液中每 30 mL 溶液中含有 0.75 ± 0.72 个颗粒。丢弃两滴后,剩余溶液中每 30 mL 含 0.14 ± 0.35 个微粒。丢弃半滴后,未检测到 MPs。大多数 MPs 是透明的(95%),不规则的碎片(55%),大小为 10-20 μm(35%),由聚乙烯制成(95%)。如果患者在一年内每天四次使用第一滴眼药水,那么每个人可能会接触到 730.0 个微粒。如果在使用前丢弃前两滴,接触到的微粒可减少到 204.4 个:结论:在市面上销售的自动滴眼液中可以观察到 MPs,人眼可能会通过使用自动滴眼液直接接触到 MPs。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Microplastic contamination in artificial tears in South Korea: Potential for direct ocular exposure.

Purpose: To investigate microplastics (MP) contamination in artificial tear (AT) products.

Method: Five hyaluronic acid ATs (two multi-use and three disposable ATs) were used to gauge MP levels in three scenarios: 1) initial drop and remaining liquid after opening the lid upward; 2) remaining liquid after opening the lid downward and discarding two drops; and 3) remaining liquid after opening the lid downward and discarding half of it. Raman spectroscopy was used to identify the quantity, morphological characteristics, and composition of MPs. Scanning electron microscopy/energy dispersive spectroscopy was used to examine the surface traits and elements of MPs and ATs.

Results: MPs were detected in 4 out of 5 ATs in the initial drops, containing 0.50 ± 0.65 particles/30 mL, whereas the remaining solution had 0.75 ± 0.72 particles/30 mL. After discarding two drops, 0.14 ± 0.35 particles/30 mL were present in the remaining solution. No MPs were detected after discarding half drops. Most MPs were transparent (95 %), irregular fragments (55 %) sized 10-20 μm (35 %), and made of polyethylene (95 %). If patients use the first drops of ATs four times a day for a year, individuals can be exposed to 730.0 particles. This exposure can be reduced to 204.4 particles by discarding the first two drops before use.

Conclusion: MPs are observed in commercially available ATs, and human eyes may be directly exposed to MPs through the use of ATs.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
7.60
自引率
18.80%
发文量
198
审稿时长
55 days
期刊介绍: Contact Lens & Anterior Eye is a research-based journal covering all aspects of contact lens theory and practice, including original articles on invention and innovations, as well as the regular features of: Case Reports; Literary Reviews; Editorials; Instrumentation and Techniques and Dates of Professional Meetings.
期刊最新文献
Validation and repeatability assessment of the Chinese version of the Ocular Surface Disease Index (OSDI), 5-item dry eye (DEQ-5), and contact lens dry eye questionnaire-8 (CLDEQ-8) questionnaires. Artificial intelligence-assisted fitting method using corneal topography outcomes enhances success rate in orthokeratology lens fitting. Randomised controlled trial on effects of topical insulin compared to artificial tears and normal saline on tear inflammatory mediator levels and clinical parameters in diabetics with dry eye disease. Development and evaluation of ocular antibiotic-loaded soluble film inserts. Digital eye strain and clinical correlates in older adults.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1