泵送微管中带有焦耳加热、粘性耗散和磁场效应的埃利斯流体的电渗机制。

IF 1.7 4区 医学 Q4 BIOPHYSICS Journal of Biomechanical Engineering-Transactions of the Asme Pub Date : 2025-01-01 DOI:10.1115/1.4067083
Saima Noreen, Farida Aslam
{"title":"泵送微管中带有焦耳加热、粘性耗散和磁场效应的埃利斯流体的电渗机制。","authors":"Saima Noreen, Farida Aslam","doi":"10.1115/1.4067083","DOIUrl":null,"url":null,"abstract":"<p><p>The dynamics of electro-osmotically generated flow of biological viscoelastic fluid in a cylindrical geometry are investigated in this paper. This flux is the result of walls contracting and relaxing sinusoidally in a magnetic environment. The blood's viscoelasticity and shear-thinning viscosity are the primary causes of its non-Newtonian characteristics. Hence, the rheology of the fluid (blood) is accurately captured with the Ellis fluid model. Both Joule heating and viscous dissipation are accounted for during thermal analysis. The electric potential induced in the electric double layer (EDL) is obtained by applying the Debye-Huckel linearization to the nonlinear Poisson-Boltzmann equation. Mathematical modelling is incorporated in cylindrical coordinates in wave frame of reference. Assuming a long wavelength and creeping flow characterized by a low Reynolds number, the Ellis fluid model's governing equations are simplified. The resulting differential equations are evaluated numerically via the built-in tool NDSolve of the Mathematica. Graphical representations are utilized to visually and comprehensively assess the thermal characteristics, flow features, heat transfer coefficient, and skin friction coefficient. Various factors are taken into consideration, including the impact of Ellis fluid parameters, electric double layer, magnetic field, Brinkman number, and Ohmic dissipation. Ellis fluid's axial velocity boosts with a rise of the electro-osmotic parameter and power-law index while decreasing with an increase in the Hartmann number and material fluid parameter. The fluid temperature is directly proportional to EDL parameter and parameters of Ohmic and viscous dissipation. The presence of both electric and magnetic fields may aid in the management and control of Ellis fluid (blood) mobility at different temperatures, which is helpful in controlling bleeding during surgeries. The current model may be used in clinical scenarios involving the gastrointestinal system and capillaries, electrohydrodynamic therapy, delivery of drugs in pharmacological, and biomedical devices. This research creates a theoretical model that can predict the effects of different parameters on the characteristics of fluid flows that are like blood.</p>","PeriodicalId":54871,"journal":{"name":"Journal of Biomechanical Engineering-Transactions of the Asme","volume":" ","pages":""},"PeriodicalIF":1.7000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Electro-Osmotic Mechanism of Ellis Fluid With Joule Heating, Viscous Dissipation, and Magnetic Field Effects in a Pumping Microtube.\",\"authors\":\"Saima Noreen, Farida Aslam\",\"doi\":\"10.1115/1.4067083\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The dynamics of electro-osmotically generated flow of biological viscoelastic fluid in a cylindrical geometry are investigated in this paper. This flux is the result of walls contracting and relaxing sinusoidally in a magnetic environment. The blood's viscoelasticity and shear-thinning viscosity are the primary causes of its non-Newtonian characteristics. Hence, the rheology of the fluid (blood) is accurately captured with the Ellis fluid model. Both Joule heating and viscous dissipation are accounted for during thermal analysis. The electric potential induced in the electric double layer (EDL) is obtained by applying the Debye-Huckel linearization to the nonlinear Poisson-Boltzmann equation. Mathematical modelling is incorporated in cylindrical coordinates in wave frame of reference. Assuming a long wavelength and creeping flow characterized by a low Reynolds number, the Ellis fluid model's governing equations are simplified. The resulting differential equations are evaluated numerically via the built-in tool NDSolve of the Mathematica. Graphical representations are utilized to visually and comprehensively assess the thermal characteristics, flow features, heat transfer coefficient, and skin friction coefficient. Various factors are taken into consideration, including the impact of Ellis fluid parameters, electric double layer, magnetic field, Brinkman number, and Ohmic dissipation. Ellis fluid's axial velocity boosts with a rise of the electro-osmotic parameter and power-law index while decreasing with an increase in the Hartmann number and material fluid parameter. The fluid temperature is directly proportional to EDL parameter and parameters of Ohmic and viscous dissipation. The presence of both electric and magnetic fields may aid in the management and control of Ellis fluid (blood) mobility at different temperatures, which is helpful in controlling bleeding during surgeries. The current model may be used in clinical scenarios involving the gastrointestinal system and capillaries, electrohydrodynamic therapy, delivery of drugs in pharmacological, and biomedical devices. This research creates a theoretical model that can predict the effects of different parameters on the characteristics of fluid flows that are like blood.</p>\",\"PeriodicalId\":54871,\"journal\":{\"name\":\"Journal of Biomechanical Engineering-Transactions of the Asme\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2025-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Biomechanical Engineering-Transactions of the Asme\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1115/1.4067083\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"BIOPHYSICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Biomechanical Engineering-Transactions of the Asme","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1115/1.4067083","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"BIOPHYSICS","Score":null,"Total":0}
引用次数: 0

摘要

本文研究了生物粘弹性流体在圆柱形几何体中电磁产生的流动动力学。这种流动是壁在磁环境中正弦收缩和松弛的结果。埃利斯流体(血液)模型准确捕捉了流体的流变性。热分析过程中考虑了焦耳热和粘性耗散。通过将 Debye-Huckel 线性化应用于非线性泊松-波尔兹曼方程,可获得 EDL 中感应的电动势。数学模型是以圆柱坐标为波形参照系建立的。假设波长较长,雷诺数较低,则简化了埃利斯流体模型的控制方程。随后,利用集成在 Mathematica 中的 NDSolve 工具对微分方程进行数值计算。利用图形表示法可直观、全面地评估热特性、流动特征、传热系数和表皮摩擦系数。考虑了各种因素,包括埃利斯流体参数、电双层、磁场、布林克曼数和欧姆耗散的影响。埃利斯流体的轴向速度随着电渗参数和幂律指数的增加而提高,同时随着哈特曼数和材料流体参数的增加而降低。流体温度与 EDL 参数以及欧姆耗散和粘性耗散参数成正比。目前的模型可用于涉及胃肠道系统和毛细血管、电流体动力疗法、药理学药物输送和生物医学设备的临床场景。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Electro-Osmotic Mechanism of Ellis Fluid With Joule Heating, Viscous Dissipation, and Magnetic Field Effects in a Pumping Microtube.

The dynamics of electro-osmotically generated flow of biological viscoelastic fluid in a cylindrical geometry are investigated in this paper. This flux is the result of walls contracting and relaxing sinusoidally in a magnetic environment. The blood's viscoelasticity and shear-thinning viscosity are the primary causes of its non-Newtonian characteristics. Hence, the rheology of the fluid (blood) is accurately captured with the Ellis fluid model. Both Joule heating and viscous dissipation are accounted for during thermal analysis. The electric potential induced in the electric double layer (EDL) is obtained by applying the Debye-Huckel linearization to the nonlinear Poisson-Boltzmann equation. Mathematical modelling is incorporated in cylindrical coordinates in wave frame of reference. Assuming a long wavelength and creeping flow characterized by a low Reynolds number, the Ellis fluid model's governing equations are simplified. The resulting differential equations are evaluated numerically via the built-in tool NDSolve of the Mathematica. Graphical representations are utilized to visually and comprehensively assess the thermal characteristics, flow features, heat transfer coefficient, and skin friction coefficient. Various factors are taken into consideration, including the impact of Ellis fluid parameters, electric double layer, magnetic field, Brinkman number, and Ohmic dissipation. Ellis fluid's axial velocity boosts with a rise of the electro-osmotic parameter and power-law index while decreasing with an increase in the Hartmann number and material fluid parameter. The fluid temperature is directly proportional to EDL parameter and parameters of Ohmic and viscous dissipation. The presence of both electric and magnetic fields may aid in the management and control of Ellis fluid (blood) mobility at different temperatures, which is helpful in controlling bleeding during surgeries. The current model may be used in clinical scenarios involving the gastrointestinal system and capillaries, electrohydrodynamic therapy, delivery of drugs in pharmacological, and biomedical devices. This research creates a theoretical model that can predict the effects of different parameters on the characteristics of fluid flows that are like blood.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.40
自引率
5.90%
发文量
169
审稿时长
4-8 weeks
期刊介绍: Artificial Organs and Prostheses; Bioinstrumentation and Measurements; Bioheat Transfer; Biomaterials; Biomechanics; Bioprocess Engineering; Cellular Mechanics; Design and Control of Biological Systems; Physiological Systems.
期刊最新文献
Effect of Blade Thickness on Hemodynamics and Hemolysis: A Case Study of Pediatric Centrifugal Blood Pumps. Effect of Compressive Strain Rates on Viscoelasticity and Water Content in Intact Porcine Stomach Wall Tissues. Estimation of Joint Kinetics During Manual Material Handling Using Inertial Motion Capture: A Follow-Up Study. Image-Based Estimation of Left Ventricular Myocardial Stiffness. Phenomenological Muscle Constitutive Model With Actin-Titin Binding for Simulating Active Stretching.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1