Letícia C S Santos, Landulfo Silveira, Marcos T T Pacheco
{"title":"运动员尿液肌酸和磷酸盐的拉曼光谱分析:训练前和训练后评估","authors":"Letícia C S Santos, Landulfo Silveira, Marcos T T Pacheco","doi":"10.1002/jbio.202400210","DOIUrl":null,"url":null,"abstract":"<p><p>The aim of this study was to detect biochemical components in the urine of bodybuilders who ingested creatine pretraining compared to individuals who did not ingest creatine after physical exercise using Raman spectroscopy. Twenty volunteers practicing bodybuilding were selected to collect pre- and post-training urine samples, where 10 volunteers ingested creatine 30 min before pretraining urine collection (creatine group), and 10 did not (control group). The samples were subjected to Raman spectroscopy, and the spectra of both creatine and control groups and the difference (post-pre) for both groups were analyzed. Principal component analysis (PCA) technique was applied to the samples. The results showed peaks of creatine and phosphate in urine after training (creatine post-training group), suggesting that part of the creatine was absorbed and metabolized, and part was excreted. Raman spectroscopy could be applied to detect biocompounds in urine, such as unmetabolized creatine and phosphate.</p>","PeriodicalId":94068,"journal":{"name":"Journal of biophotonics","volume":" ","pages":"e202400210"},"PeriodicalIF":0.0000,"publicationDate":"2024-11-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Raman Spectroscopic Analysis of Urinary Creatine and Phosphate in Athletes: Pre- and Post-Training Assessment.\",\"authors\":\"Letícia C S Santos, Landulfo Silveira, Marcos T T Pacheco\",\"doi\":\"10.1002/jbio.202400210\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The aim of this study was to detect biochemical components in the urine of bodybuilders who ingested creatine pretraining compared to individuals who did not ingest creatine after physical exercise using Raman spectroscopy. Twenty volunteers practicing bodybuilding were selected to collect pre- and post-training urine samples, where 10 volunteers ingested creatine 30 min before pretraining urine collection (creatine group), and 10 did not (control group). The samples were subjected to Raman spectroscopy, and the spectra of both creatine and control groups and the difference (post-pre) for both groups were analyzed. Principal component analysis (PCA) technique was applied to the samples. The results showed peaks of creatine and phosphate in urine after training (creatine post-training group), suggesting that part of the creatine was absorbed and metabolized, and part was excreted. Raman spectroscopy could be applied to detect biocompounds in urine, such as unmetabolized creatine and phosphate.</p>\",\"PeriodicalId\":94068,\"journal\":{\"name\":\"Journal of biophotonics\",\"volume\":\" \",\"pages\":\"e202400210\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-11-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of biophotonics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1002/jbio.202400210\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of biophotonics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1002/jbio.202400210","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Raman Spectroscopic Analysis of Urinary Creatine and Phosphate in Athletes: Pre- and Post-Training Assessment.
The aim of this study was to detect biochemical components in the urine of bodybuilders who ingested creatine pretraining compared to individuals who did not ingest creatine after physical exercise using Raman spectroscopy. Twenty volunteers practicing bodybuilding were selected to collect pre- and post-training urine samples, where 10 volunteers ingested creatine 30 min before pretraining urine collection (creatine group), and 10 did not (control group). The samples were subjected to Raman spectroscopy, and the spectra of both creatine and control groups and the difference (post-pre) for both groups were analyzed. Principal component analysis (PCA) technique was applied to the samples. The results showed peaks of creatine and phosphate in urine after training (creatine post-training group), suggesting that part of the creatine was absorbed and metabolized, and part was excreted. Raman spectroscopy could be applied to detect biocompounds in urine, such as unmetabolized creatine and phosphate.