提高噪音中的语音清晰度和空间感:助听器麦克风位置的关键作用。

IF 3.2 3区 医学 Q2 NEUROSCIENCES Frontiers in Neuroscience Pub Date : 2024-10-21 eCollection Date: 2024-01-01 DOI:10.3389/fnins.2024.1475122
Eyyup Kara, Nurşah Özal, Burcu Deniz, Talha Çögen, Rışvan Deniz, Kübra Aydın, Cenk Caba, Begüm Bahar Yılmaz
{"title":"提高噪音中的语音清晰度和空间感:助听器麦克风位置的关键作用。","authors":"Eyyup Kara, Nurşah Özal, Burcu Deniz, Talha Çögen, Rışvan Deniz, Kübra Aydın, Cenk Caba, Begüm Bahar Yılmaz","doi":"10.3389/fnins.2024.1475122","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Hearing aid (HA) manufacturers have introduced behind-the-ear (BTE) models where the microphone is positioned in the ear canal, which could impact auditory performance by distorting the pinna's acoustic cues. This study aimed to compare two different BTE HAs with varying microphone positions: the receiver in the ear (RITE) and the transducer in the ear (TIE).</p><p><strong>Methods: </strong>The study involved 10 participants who had never used HAs before. They used both RITE and TIE HAs bilaterally for 3 weeks. Auditory performance was assessed through free field hearing assessments (hearing thresholds, speech recognition threshold, and speech discrimination score), the Turkish Matrix Sentence Test (TURMatrix), a sound localization test, and the Satisfaction with Amplification in Daily Living (SADL) questionnaire.</p><p><strong>Results: </strong>There was no significant difference between TIE and RITE in the free field hearing assessments. However, TIE outperformed RITE in non-adaptive TURMatrix scores in quiet, adaptive TURMatrix scores in noise, and sound localization accuracy at various angles. SADL sub-scores (Positive Effect, Service and Cost, and Personal Image) and overall satisfaction scores were significantly better for TIE.</p><p><strong>Discussion: </strong>The microphone position in HAs can influence auditory performance. This study demonstrated that TIE provided better speech intelligibility, localization accuracy, and user satisfaction compared to RITE.</p>","PeriodicalId":12639,"journal":{"name":"Frontiers in Neuroscience","volume":null,"pages":null},"PeriodicalIF":3.2000,"publicationDate":"2024-10-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11543641/pdf/","citationCount":"0","resultStr":"{\"title\":\"Improving speech intelligibility in noise and spatial perception: the critical role of hearing aid microphone position.\",\"authors\":\"Eyyup Kara, Nurşah Özal, Burcu Deniz, Talha Çögen, Rışvan Deniz, Kübra Aydın, Cenk Caba, Begüm Bahar Yılmaz\",\"doi\":\"10.3389/fnins.2024.1475122\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>Hearing aid (HA) manufacturers have introduced behind-the-ear (BTE) models where the microphone is positioned in the ear canal, which could impact auditory performance by distorting the pinna's acoustic cues. This study aimed to compare two different BTE HAs with varying microphone positions: the receiver in the ear (RITE) and the transducer in the ear (TIE).</p><p><strong>Methods: </strong>The study involved 10 participants who had never used HAs before. They used both RITE and TIE HAs bilaterally for 3 weeks. Auditory performance was assessed through free field hearing assessments (hearing thresholds, speech recognition threshold, and speech discrimination score), the Turkish Matrix Sentence Test (TURMatrix), a sound localization test, and the Satisfaction with Amplification in Daily Living (SADL) questionnaire.</p><p><strong>Results: </strong>There was no significant difference between TIE and RITE in the free field hearing assessments. However, TIE outperformed RITE in non-adaptive TURMatrix scores in quiet, adaptive TURMatrix scores in noise, and sound localization accuracy at various angles. SADL sub-scores (Positive Effect, Service and Cost, and Personal Image) and overall satisfaction scores were significantly better for TIE.</p><p><strong>Discussion: </strong>The microphone position in HAs can influence auditory performance. This study demonstrated that TIE provided better speech intelligibility, localization accuracy, and user satisfaction compared to RITE.</p>\",\"PeriodicalId\":12639,\"journal\":{\"name\":\"Frontiers in Neuroscience\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":3.2000,\"publicationDate\":\"2024-10-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11543641/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Frontiers in Neuroscience\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.3389/fnins.2024.1475122\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q2\",\"JCRName\":\"NEUROSCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Frontiers in Neuroscience","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3389/fnins.2024.1475122","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"NEUROSCIENCES","Score":null,"Total":0}
引用次数: 0

摘要

导言:助听器(HA)制造商推出了耳背式(BTE)助听器,这种助听器的麦克风位于耳道内,可能会扭曲耳廓的声学线索,从而影响听觉效果。本研究旨在比较两种不同麦克风位置的耳背式助听器:耳内接收器(RITE)和耳内换能器(TIE):研究涉及 10 名从未使用过人工耳蜗的参与者。他们双侧使用 RITE 和 TIE 助听器 3 周。通过自由声场听力评估(听阈、言语识别阈值和言语辨别分数)、土耳其矩阵句子测试(TURMatrix)、声音定位测试和日常生活中对扩音的满意度(SADL)问卷对听觉表现进行评估:在自由声场听力评估中,TIE 和 RITE 没有明显差异。但是,在安静环境下的非适应性 TURMatrix 分数、噪音环境下的适应性 TURMatrix 分数以及不同角度的声音定位准确度方面,TIE 都优于 RITE。TIE 的 SADL 分项得分(积极效果、服务和成本以及个人形象)和总体满意度得分明显高于 RITE:讨论:助听器中麦克风的位置会影响听觉效果。本研究表明,与 RITE 相比,TIE 可提供更好的语音清晰度、定位准确性和用户满意度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Improving speech intelligibility in noise and spatial perception: the critical role of hearing aid microphone position.

Introduction: Hearing aid (HA) manufacturers have introduced behind-the-ear (BTE) models where the microphone is positioned in the ear canal, which could impact auditory performance by distorting the pinna's acoustic cues. This study aimed to compare two different BTE HAs with varying microphone positions: the receiver in the ear (RITE) and the transducer in the ear (TIE).

Methods: The study involved 10 participants who had never used HAs before. They used both RITE and TIE HAs bilaterally for 3 weeks. Auditory performance was assessed through free field hearing assessments (hearing thresholds, speech recognition threshold, and speech discrimination score), the Turkish Matrix Sentence Test (TURMatrix), a sound localization test, and the Satisfaction with Amplification in Daily Living (SADL) questionnaire.

Results: There was no significant difference between TIE and RITE in the free field hearing assessments. However, TIE outperformed RITE in non-adaptive TURMatrix scores in quiet, adaptive TURMatrix scores in noise, and sound localization accuracy at various angles. SADL sub-scores (Positive Effect, Service and Cost, and Personal Image) and overall satisfaction scores were significantly better for TIE.

Discussion: The microphone position in HAs can influence auditory performance. This study demonstrated that TIE provided better speech intelligibility, localization accuracy, and user satisfaction compared to RITE.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Frontiers in Neuroscience
Frontiers in Neuroscience NEUROSCIENCES-
CiteScore
6.20
自引率
4.70%
发文量
2070
审稿时长
14 weeks
期刊介绍: Neural Technology is devoted to the convergence between neurobiology and quantum-, nano- and micro-sciences. In our vision, this interdisciplinary approach should go beyond the technological development of sophisticated methods and should contribute in generating a genuine change in our discipline.
期刊最新文献
Analysis of the correlation and influencing factors between delirium, sleep, self-efficacy, anxiety, and depression in patients with traumatic brain injury: a cohort study. Microglia: roles and genetic risk in Parkinson's disease. Nomogram model based on clinical factors and autonomic nervous system activity for predicting residual renal function decline in patients undergoing peritoneal dialysis. Cognitive assessment in myalgic encephalomyelitis/chronic fatigue syndrome (ME/CFS): a cognitive substudy of the multi-site clinical assessment of ME/CFS (MCAM). Consistent genes associated with structural changes in clinical Alzheimer's disease spectrum.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1