Sai Liu, Kazuyuki Oshita, Wenjing Guo, Masaki Takaoka
{"title":"日本污泥处理过程中微塑料的行为和流动。","authors":"Sai Liu, Kazuyuki Oshita, Wenjing Guo, Masaki Takaoka","doi":"10.1016/j.scitotenv.2024.177553","DOIUrl":null,"url":null,"abstract":"<p><p>Microplastic (MP) pollution is a growing public and scientific concern. In urban environments, wastewater treatment plants (WWTPs) are major sources of MPs. This study sampled sludge and separated water from each sludge treatment unit in two WWTPs in Osaka, Japan. Analyzing method for MPs in sewage sludge was optimized, ultrasonic pretreatment and double digestion were introduced into the analyzing method of MPs in sewage sludge, recovering test of standard MPs proved its high efficiency. Then MPs larger than 100 μm were extracted and analyzed, their size and type were recorded, the MP concentration was calculated, and the MP flow in the sludge treatment system was estimated. MPs were detected at every step of the sludge treatment process, and 13 types of MPs were identified. The MP concentration in sludge ranged from 81 ± 48 to 6470 ± 1490 particles/kg dry sludge (DS). In the separated water, MP concentrations were much lower, ranging from 0 to 1740 ± 794 particles/kg DS. During the thickening and dewatering processes, nearly all MPs were transferred into thickened or dewatered sludge; only 5-10 % of MPs returned to the primary sedimentation pond with the separated water. The most common types of MPs were PMMA, PE, and PS. No significant differences in MP type distributions were observed among sampling batches; however, significant differences in a few types of MPs were detected between treatment units, which requires further investigation. All detected MPs were smaller than 1000 μm; larger MPs might have been removed in the grit chamber before reaching the primary or secondary sedimentation ponds. Overall, the particle size distribution did not substantially change during sludge treatment.</p>","PeriodicalId":422,"journal":{"name":"Science of the Total Environment","volume":" ","pages":"177553"},"PeriodicalIF":8.2000,"publicationDate":"2024-12-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Behavior and flow of microplastics during sludge treatment in Japan.\",\"authors\":\"Sai Liu, Kazuyuki Oshita, Wenjing Guo, Masaki Takaoka\",\"doi\":\"10.1016/j.scitotenv.2024.177553\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Microplastic (MP) pollution is a growing public and scientific concern. In urban environments, wastewater treatment plants (WWTPs) are major sources of MPs. This study sampled sludge and separated water from each sludge treatment unit in two WWTPs in Osaka, Japan. Analyzing method for MPs in sewage sludge was optimized, ultrasonic pretreatment and double digestion were introduced into the analyzing method of MPs in sewage sludge, recovering test of standard MPs proved its high efficiency. Then MPs larger than 100 μm were extracted and analyzed, their size and type were recorded, the MP concentration was calculated, and the MP flow in the sludge treatment system was estimated. MPs were detected at every step of the sludge treatment process, and 13 types of MPs were identified. The MP concentration in sludge ranged from 81 ± 48 to 6470 ± 1490 particles/kg dry sludge (DS). In the separated water, MP concentrations were much lower, ranging from 0 to 1740 ± 794 particles/kg DS. During the thickening and dewatering processes, nearly all MPs were transferred into thickened or dewatered sludge; only 5-10 % of MPs returned to the primary sedimentation pond with the separated water. The most common types of MPs were PMMA, PE, and PS. No significant differences in MP type distributions were observed among sampling batches; however, significant differences in a few types of MPs were detected between treatment units, which requires further investigation. All detected MPs were smaller than 1000 μm; larger MPs might have been removed in the grit chamber before reaching the primary or secondary sedimentation ponds. Overall, the particle size distribution did not substantially change during sludge treatment.</p>\",\"PeriodicalId\":422,\"journal\":{\"name\":\"Science of the Total Environment\",\"volume\":\" \",\"pages\":\"177553\"},\"PeriodicalIF\":8.2000,\"publicationDate\":\"2024-12-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Science of the Total Environment\",\"FirstCategoryId\":\"93\",\"ListUrlMain\":\"https://doi.org/10.1016/j.scitotenv.2024.177553\",\"RegionNum\":1,\"RegionCategory\":\"环境科学与生态学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/11/18 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"ENVIRONMENTAL SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Science of the Total Environment","FirstCategoryId":"93","ListUrlMain":"https://doi.org/10.1016/j.scitotenv.2024.177553","RegionNum":1,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/11/18 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"ENVIRONMENTAL SCIENCES","Score":null,"Total":0}
Behavior and flow of microplastics during sludge treatment in Japan.
Microplastic (MP) pollution is a growing public and scientific concern. In urban environments, wastewater treatment plants (WWTPs) are major sources of MPs. This study sampled sludge and separated water from each sludge treatment unit in two WWTPs in Osaka, Japan. Analyzing method for MPs in sewage sludge was optimized, ultrasonic pretreatment and double digestion were introduced into the analyzing method of MPs in sewage sludge, recovering test of standard MPs proved its high efficiency. Then MPs larger than 100 μm were extracted and analyzed, their size and type were recorded, the MP concentration was calculated, and the MP flow in the sludge treatment system was estimated. MPs were detected at every step of the sludge treatment process, and 13 types of MPs were identified. The MP concentration in sludge ranged from 81 ± 48 to 6470 ± 1490 particles/kg dry sludge (DS). In the separated water, MP concentrations were much lower, ranging from 0 to 1740 ± 794 particles/kg DS. During the thickening and dewatering processes, nearly all MPs were transferred into thickened or dewatered sludge; only 5-10 % of MPs returned to the primary sedimentation pond with the separated water. The most common types of MPs were PMMA, PE, and PS. No significant differences in MP type distributions were observed among sampling batches; however, significant differences in a few types of MPs were detected between treatment units, which requires further investigation. All detected MPs were smaller than 1000 μm; larger MPs might have been removed in the grit chamber before reaching the primary or secondary sedimentation ponds. Overall, the particle size distribution did not substantially change during sludge treatment.
期刊介绍:
The Science of the Total Environment is an international journal dedicated to scientific research on the environment and its interaction with humanity. It covers a wide range of disciplines and seeks to publish innovative, hypothesis-driven, and impactful research that explores the entire environment, including the atmosphere, lithosphere, hydrosphere, biosphere, and anthroposphere.
The journal's updated Aims & Scope emphasizes the importance of interdisciplinary environmental research with broad impact. Priority is given to studies that advance fundamental understanding and explore the interconnectedness of multiple environmental spheres. Field studies are preferred, while laboratory experiments must demonstrate significant methodological advancements or mechanistic insights with direct relevance to the environment.