Yang Ye, Youyou Chen, Hao Jiang, Jiling Zeng, Xingchen Wang, Ying Yang, Xiang Lan Liu, XuLin Hong, Bei Wang, Ya Xun Sun, Dongwu Lai, Xi-Qi Xu, Guo-Sheng Fu
{"title":"在心脏植入式电子设备植入过程中采用无腔起搏导线鞘引导法进行心内膜活检的可行性和安全性。","authors":"Yang Ye, Youyou Chen, Hao Jiang, Jiling Zeng, Xingchen Wang, Ying Yang, Xiang Lan Liu, XuLin Hong, Bei Wang, Ya Xun Sun, Dongwu Lai, Xi-Qi Xu, Guo-Sheng Fu","doi":"10.1016/j.hrthm.2024.11.018","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Patients with cardiovascular implantable electronic devices (CIEDs) indication are complicated with special cardiomyopathy or other unspecified cardiac abnormalities and may need endomyocardial biopsy (EMB). However, EMB by a bioptome is usually avoided to reduce the risk of lead displacement in the CIED peri-procedural period.</p><p><strong>Objective: </strong>We aimed to assess the safety and feasibility of a novel approach for transvenous right ventricular (RV) EMB using the lead-sheath method (L-S-M) during CIED implantation and compared it to the traditional bioptome method (T-B-M).</p><p><strong>Methods: </strong>Consecutive eighty patients referred for EMB were enrolled. In the L-S-M group, a sheath with a lumenless pacing lead was positioned toward the middle to apical interventricular septum under fluoroscopy (n=60). The CIED implantation was performed through the same venous access site. In the T-B-M group, a bioptome was used (n=20). The clinical characteristics, procedural details, success rate and complications were evaluated.</p><p><strong>Results: </strong>380 RV EMBs procedures were performed with comparable 4.1±0.8 in the L-S-M group and 3.8±0.8 samples/patient in the T-B-M group. In the L-S-M group, seven (11.7%) patients experienced minor complications with 3 transient right bundle branch block, 2 transient atrioventricular block (AVB) and 2 regional minor device pocket hematomas. In the T-B-M group, three (15%) experienced one temporary pacing for transient AVB, one chest discomfort and one regional hematoma. No cardiac tamponade was detected.</p><p><strong>Conclusions: </strong>RV EMB by the innovative L-S-M method is technically feasible, safe and can yield valuable and early diagnostic insights for patients who are candidates for CIEDs.</p>","PeriodicalId":12886,"journal":{"name":"Heart rhythm","volume":" ","pages":""},"PeriodicalIF":5.6000,"publicationDate":"2024-11-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The feasibility and safety of Endomyocardial Biopsy by lumenless pacing lead-sheath directed method during the Cardiac Implantable Electronic Device implantation.\",\"authors\":\"Yang Ye, Youyou Chen, Hao Jiang, Jiling Zeng, Xingchen Wang, Ying Yang, Xiang Lan Liu, XuLin Hong, Bei Wang, Ya Xun Sun, Dongwu Lai, Xi-Qi Xu, Guo-Sheng Fu\",\"doi\":\"10.1016/j.hrthm.2024.11.018\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Patients with cardiovascular implantable electronic devices (CIEDs) indication are complicated with special cardiomyopathy or other unspecified cardiac abnormalities and may need endomyocardial biopsy (EMB). However, EMB by a bioptome is usually avoided to reduce the risk of lead displacement in the CIED peri-procedural period.</p><p><strong>Objective: </strong>We aimed to assess the safety and feasibility of a novel approach for transvenous right ventricular (RV) EMB using the lead-sheath method (L-S-M) during CIED implantation and compared it to the traditional bioptome method (T-B-M).</p><p><strong>Methods: </strong>Consecutive eighty patients referred for EMB were enrolled. In the L-S-M group, a sheath with a lumenless pacing lead was positioned toward the middle to apical interventricular septum under fluoroscopy (n=60). The CIED implantation was performed through the same venous access site. In the T-B-M group, a bioptome was used (n=20). The clinical characteristics, procedural details, success rate and complications were evaluated.</p><p><strong>Results: </strong>380 RV EMBs procedures were performed with comparable 4.1±0.8 in the L-S-M group and 3.8±0.8 samples/patient in the T-B-M group. In the L-S-M group, seven (11.7%) patients experienced minor complications with 3 transient right bundle branch block, 2 transient atrioventricular block (AVB) and 2 regional minor device pocket hematomas. In the T-B-M group, three (15%) experienced one temporary pacing for transient AVB, one chest discomfort and one regional hematoma. No cardiac tamponade was detected.</p><p><strong>Conclusions: </strong>RV EMB by the innovative L-S-M method is technically feasible, safe and can yield valuable and early diagnostic insights for patients who are candidates for CIEDs.</p>\",\"PeriodicalId\":12886,\"journal\":{\"name\":\"Heart rhythm\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":5.6000,\"publicationDate\":\"2024-11-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Heart rhythm\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1016/j.hrthm.2024.11.018\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Heart rhythm","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.hrthm.2024.11.018","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
The feasibility and safety of Endomyocardial Biopsy by lumenless pacing lead-sheath directed method during the Cardiac Implantable Electronic Device implantation.
Background: Patients with cardiovascular implantable electronic devices (CIEDs) indication are complicated with special cardiomyopathy or other unspecified cardiac abnormalities and may need endomyocardial biopsy (EMB). However, EMB by a bioptome is usually avoided to reduce the risk of lead displacement in the CIED peri-procedural period.
Objective: We aimed to assess the safety and feasibility of a novel approach for transvenous right ventricular (RV) EMB using the lead-sheath method (L-S-M) during CIED implantation and compared it to the traditional bioptome method (T-B-M).
Methods: Consecutive eighty patients referred for EMB were enrolled. In the L-S-M group, a sheath with a lumenless pacing lead was positioned toward the middle to apical interventricular septum under fluoroscopy (n=60). The CIED implantation was performed through the same venous access site. In the T-B-M group, a bioptome was used (n=20). The clinical characteristics, procedural details, success rate and complications were evaluated.
Results: 380 RV EMBs procedures were performed with comparable 4.1±0.8 in the L-S-M group and 3.8±0.8 samples/patient in the T-B-M group. In the L-S-M group, seven (11.7%) patients experienced minor complications with 3 transient right bundle branch block, 2 transient atrioventricular block (AVB) and 2 regional minor device pocket hematomas. In the T-B-M group, three (15%) experienced one temporary pacing for transient AVB, one chest discomfort and one regional hematoma. No cardiac tamponade was detected.
Conclusions: RV EMB by the innovative L-S-M method is technically feasible, safe and can yield valuable and early diagnostic insights for patients who are candidates for CIEDs.
期刊介绍:
HeartRhythm, the official Journal of the Heart Rhythm Society and the Cardiac Electrophysiology Society, is a unique journal for fundamental discovery and clinical applicability.
HeartRhythm integrates the entire cardiac electrophysiology (EP) community from basic and clinical academic researchers, private practitioners, engineers, allied professionals, industry, and trainees, all of whom are vital and interdependent members of our EP community.
The Heart Rhythm Society is the international leader in science, education, and advocacy for cardiac arrhythmia professionals and patients, and the primary information resource on heart rhythm disorders. Its mission is to improve the care of patients by promoting research, education, and optimal health care policies and standards.