{"title":"用于消防安全评估的商业和大学办公楼数字化燃料负荷调查","authors":"Yifei Ding, Wai Kit Cheung, Yuxin Zhang, Xinyan Huang","doi":"10.1016/j.firesaf.2024.104287","DOIUrl":null,"url":null,"abstract":"<div><div>Fuel load significantly affects fire development in compartments, and its design value derives from the statistical results of numerous surveys. This work enhances the fuel load database by employing a digitized survey method to assess 27 university and commercial offices in Hong Kong and Mainland, China. The results revealed significant differences in fuel load densities: university offices averaged 382 MJ/m<sup>2</sup> (SD: 297 MJ/m<sup>2</sup>) and commercial offices averaged 1804 MJ/m<sup>2</sup> (SD: 1319 MJ/m<sup>2</sup>). Moreover, it proposed an online questionnaire method to overcome onsite access limitations. Furthermore, it identified higher fuel load densities in commercial offices due to higher paper-made content and greater occupancy density than university offices. The fuel load of university offices was lower than that in previous surveys and design codes, while commercial fuel load was higher. Notably, there is an increasing tendency of fuel load density and plastic combustible composition over the years. Additionally, it considers that Gompertz distribution better fits cumulative probabilities of fuel load density data with a small sample size. Overall, it provides a valuable database for future fire scenario design, fire codes edition, and fire safety assessment and discusses future collaboration with AI applications.</div></div>","PeriodicalId":50445,"journal":{"name":"Fire Safety Journal","volume":"150 ","pages":"Article 104287"},"PeriodicalIF":3.4000,"publicationDate":"2024-11-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Digitized fuel load survey in commercial and university office buildings for fire safety assessment\",\"authors\":\"Yifei Ding, Wai Kit Cheung, Yuxin Zhang, Xinyan Huang\",\"doi\":\"10.1016/j.firesaf.2024.104287\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>Fuel load significantly affects fire development in compartments, and its design value derives from the statistical results of numerous surveys. This work enhances the fuel load database by employing a digitized survey method to assess 27 university and commercial offices in Hong Kong and Mainland, China. The results revealed significant differences in fuel load densities: university offices averaged 382 MJ/m<sup>2</sup> (SD: 297 MJ/m<sup>2</sup>) and commercial offices averaged 1804 MJ/m<sup>2</sup> (SD: 1319 MJ/m<sup>2</sup>). Moreover, it proposed an online questionnaire method to overcome onsite access limitations. Furthermore, it identified higher fuel load densities in commercial offices due to higher paper-made content and greater occupancy density than university offices. The fuel load of university offices was lower than that in previous surveys and design codes, while commercial fuel load was higher. Notably, there is an increasing tendency of fuel load density and plastic combustible composition over the years. Additionally, it considers that Gompertz distribution better fits cumulative probabilities of fuel load density data with a small sample size. Overall, it provides a valuable database for future fire scenario design, fire codes edition, and fire safety assessment and discusses future collaboration with AI applications.</div></div>\",\"PeriodicalId\":50445,\"journal\":{\"name\":\"Fire Safety Journal\",\"volume\":\"150 \",\"pages\":\"Article 104287\"},\"PeriodicalIF\":3.4000,\"publicationDate\":\"2024-11-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Fire Safety Journal\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0379711224002005\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENGINEERING, CIVIL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Fire Safety Journal","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0379711224002005","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, CIVIL","Score":null,"Total":0}
Digitized fuel load survey in commercial and university office buildings for fire safety assessment
Fuel load significantly affects fire development in compartments, and its design value derives from the statistical results of numerous surveys. This work enhances the fuel load database by employing a digitized survey method to assess 27 university and commercial offices in Hong Kong and Mainland, China. The results revealed significant differences in fuel load densities: university offices averaged 382 MJ/m2 (SD: 297 MJ/m2) and commercial offices averaged 1804 MJ/m2 (SD: 1319 MJ/m2). Moreover, it proposed an online questionnaire method to overcome onsite access limitations. Furthermore, it identified higher fuel load densities in commercial offices due to higher paper-made content and greater occupancy density than university offices. The fuel load of university offices was lower than that in previous surveys and design codes, while commercial fuel load was higher. Notably, there is an increasing tendency of fuel load density and plastic combustible composition over the years. Additionally, it considers that Gompertz distribution better fits cumulative probabilities of fuel load density data with a small sample size. Overall, it provides a valuable database for future fire scenario design, fire codes edition, and fire safety assessment and discusses future collaboration with AI applications.
期刊介绍:
Fire Safety Journal is the leading publication dealing with all aspects of fire safety engineering. Its scope is purposefully wide, as it is deemed important to encourage papers from all sources within this multidisciplinary subject, thus providing a forum for its further development as a distinct engineering discipline. This is an essential step towards gaining a status equal to that enjoyed by the other engineering disciplines.