利用复合扭绞方形风管和可变间距扭绞带插入件提高层流的热性能

IF 6.4 2区 工程技术 Q1 THERMODYNAMICS Case Studies in Thermal Engineering Pub Date : 2024-11-08 DOI:10.1016/j.csite.2024.105462
V.P. Chithra , V. Jayakumar , Balaji Bakthavatchalam , Sambhaji Kashinath Kusekar , Kashif Irshad , Khairul Habib
{"title":"利用复合扭绞方形风管和可变间距扭绞带插入件提高层流的热性能","authors":"V.P. Chithra ,&nbsp;V. Jayakumar ,&nbsp;Balaji Bakthavatchalam ,&nbsp;Sambhaji Kashinath Kusekar ,&nbsp;Kashif Irshad ,&nbsp;Khairul Habib","doi":"10.1016/j.csite.2024.105462","DOIUrl":null,"url":null,"abstract":"<div><div>This study involves a computational analysis to find the effectiveness of incorporating twisted tape within a twisted square duct for improving heat transfer, focusing on laminar single-phase flow. The primary goal is to study how varying the tape pitch (y) influences the hydrothermal performance of this system. The twisted square duct pitch (S) and twist ratio (H) were kept constant. The numerical analysis is performed under conditions of uniform wall temperature, and varying the pitch ratio (y/S) across values of 0.25, 0.5,0.75, 1, 1.25, 1.5 and 1.75. The obtained findings suggest that the addition of twisted tape within the twisted square duct results in a greater rate of heat exchange and pressure drop relative to the simple twisted square duct. Research reveals that despite a higher rate of heat transfer for a pitch ratio of 0.25 the increased friction factor results in less effective thermal performance compared to the cases with pitch ratios of 0.75 and 0.5. The thermal performance factor reaches its peak at 1.32, corresponding to the Reynolds number 1000 for a pitch ratio of 0.75 case. Conversely, the lowest thermal performance factor value of 0.89 is observed at the Reynolds number 500 for pitch ratio 1.25 case.</div></div>","PeriodicalId":9658,"journal":{"name":"Case Studies in Thermal Engineering","volume":"64 ","pages":"Article 105462"},"PeriodicalIF":6.4000,"publicationDate":"2024-11-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Thermal performance enhancement of laminar flow using compound twisted square duct and variable pitch twisted tape inserts\",\"authors\":\"V.P. Chithra ,&nbsp;V. Jayakumar ,&nbsp;Balaji Bakthavatchalam ,&nbsp;Sambhaji Kashinath Kusekar ,&nbsp;Kashif Irshad ,&nbsp;Khairul Habib\",\"doi\":\"10.1016/j.csite.2024.105462\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>This study involves a computational analysis to find the effectiveness of incorporating twisted tape within a twisted square duct for improving heat transfer, focusing on laminar single-phase flow. The primary goal is to study how varying the tape pitch (y) influences the hydrothermal performance of this system. The twisted square duct pitch (S) and twist ratio (H) were kept constant. The numerical analysis is performed under conditions of uniform wall temperature, and varying the pitch ratio (y/S) across values of 0.25, 0.5,0.75, 1, 1.25, 1.5 and 1.75. The obtained findings suggest that the addition of twisted tape within the twisted square duct results in a greater rate of heat exchange and pressure drop relative to the simple twisted square duct. Research reveals that despite a higher rate of heat transfer for a pitch ratio of 0.25 the increased friction factor results in less effective thermal performance compared to the cases with pitch ratios of 0.75 and 0.5. The thermal performance factor reaches its peak at 1.32, corresponding to the Reynolds number 1000 for a pitch ratio of 0.75 case. Conversely, the lowest thermal performance factor value of 0.89 is observed at the Reynolds number 500 for pitch ratio 1.25 case.</div></div>\",\"PeriodicalId\":9658,\"journal\":{\"name\":\"Case Studies in Thermal Engineering\",\"volume\":\"64 \",\"pages\":\"Article 105462\"},\"PeriodicalIF\":6.4000,\"publicationDate\":\"2024-11-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Case Studies in Thermal Engineering\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2214157X2401493X\",\"RegionNum\":2,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"THERMODYNAMICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Case Studies in Thermal Engineering","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2214157X2401493X","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"THERMODYNAMICS","Score":null,"Total":0}
引用次数: 0

摘要

本研究涉及计算分析,以层流单相流为重点,找出在扭曲的方形管道中加入扭曲带以改善传热的有效性。主要目的是研究改变胶带间距(y)如何影响该系统的水热性能。扭曲的方形管道间距 (S) 和扭曲比 (H) 保持不变。数值分析是在壁温均匀的条件下进行的,间距比(y/S)在 0.25、0.5、0.75、1、1.25、1.5 和 1.75 之间变化。研究结果表明,与简单的扭曲方形风管相比,在扭曲方形风管中添加扭曲带会导致更高的热交换率和压降。研究表明,尽管间距比为 0.25 的热传导率更高,但与间距比为 0.75 和 0.5 的情况相比,摩擦因数的增加导致热性能效率降低。热性能系数在 1.32 时达到峰值,对应于间距比为 0.75 时的雷诺数 1000。相反,间距比为 1.25 的情况下,雷诺数为 500 时的热性能系数最低,为 0.89。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Thermal performance enhancement of laminar flow using compound twisted square duct and variable pitch twisted tape inserts
This study involves a computational analysis to find the effectiveness of incorporating twisted tape within a twisted square duct for improving heat transfer, focusing on laminar single-phase flow. The primary goal is to study how varying the tape pitch (y) influences the hydrothermal performance of this system. The twisted square duct pitch (S) and twist ratio (H) were kept constant. The numerical analysis is performed under conditions of uniform wall temperature, and varying the pitch ratio (y/S) across values of 0.25, 0.5,0.75, 1, 1.25, 1.5 and 1.75. The obtained findings suggest that the addition of twisted tape within the twisted square duct results in a greater rate of heat exchange and pressure drop relative to the simple twisted square duct. Research reveals that despite a higher rate of heat transfer for a pitch ratio of 0.25 the increased friction factor results in less effective thermal performance compared to the cases with pitch ratios of 0.75 and 0.5. The thermal performance factor reaches its peak at 1.32, corresponding to the Reynolds number 1000 for a pitch ratio of 0.75 case. Conversely, the lowest thermal performance factor value of 0.89 is observed at the Reynolds number 500 for pitch ratio 1.25 case.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Case Studies in Thermal Engineering
Case Studies in Thermal Engineering Chemical Engineering-Fluid Flow and Transfer Processes
CiteScore
8.60
自引率
11.80%
发文量
812
审稿时长
76 days
期刊介绍: Case Studies in Thermal Engineering provides a forum for the rapid publication of short, structured Case Studies in Thermal Engineering and related Short Communications. It provides an essential compendium of case studies for researchers and practitioners in the field of thermal engineering and others who are interested in aspects of thermal engineering cases that could affect other engineering processes. The journal not only publishes new and novel case studies, but also provides a forum for the publication of high quality descriptions of classic thermal engineering problems. The scope of the journal includes case studies of thermal engineering problems in components, devices and systems using existing experimental and numerical techniques in the areas of mechanical, aerospace, chemical, medical, thermal management for electronics, heat exchangers, regeneration, solar thermal energy, thermal storage, building energy conservation, and power generation. Case studies of thermal problems in other areas will also be considered.
期刊最新文献
Numerical analysis and experimental study of two-phase flow pattern and pressure drop characteristics in internally microfin tubes A novel high-temperature water cooling system utilizing cascaded cold energy from underground water plants in northern China Combustion characteristics of a 660 MW tangentially fired pulverized coal boiler considering different loads, burner combinations and horizontal deflection angles Performance evaluation of supercritical CO2 Brayton cycle with two-stage compression and intercooling Research on the mechanical and thermal properties of potting adhesive with different fillers of h-BN and MPCM
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1