基于结霜抑制性能图的变速空气源热泵结霜抑制性能评估方法和增强策略

IF 6.6 2区 工程技术 Q1 CONSTRUCTION & BUILDING TECHNOLOGY Energy and Buildings Pub Date : 2024-11-10 DOI:10.1016/j.enbuild.2024.115047
Yao Lin , Jianfei Luo , Qing Luo , Xiaoli Li , Wei Wang , Yuying Sun
{"title":"基于结霜抑制性能图的变速空气源热泵结霜抑制性能评估方法和增强策略","authors":"Yao Lin ,&nbsp;Jianfei Luo ,&nbsp;Qing Luo ,&nbsp;Xiaoli Li ,&nbsp;Wei Wang ,&nbsp;Yuying Sun","doi":"10.1016/j.enbuild.2024.115047","DOIUrl":null,"url":null,"abstract":"<div><div>It is well established that the configuration and operation of variable speed air source heat pumps (VS ASHPs) can significantly influence their frosting performance. However, there is currently no effective method to conveniently and accurately evaluate the frosting suppression performance of these units. This paper addresses this gap by proposing a novel evaluation method based on a frosting suppression map for VS ASHPs. Firstly, an experimental setup with four ASHP units and developed frosting suppression maps is described. Second, a method for evaluating the frosting suppression performance of VS ASHP is developed based on the map. Thirdly, a comprehensive evaluation of the frosting suppression performance of the experimental unit is carried out. It is shown that the <em>β</em> values of the four units under the constitutive configuration were 0.74, 0.12, 0.21, and 0.52, and the frosting suppression performance was evaluated as Good, Poor, Fair, and Average, respectively. It could be enhanced and improved to 0.89 (Excellent), 0.24 (Fair), 0.64 (Good), and 0.63 (Good) after applying the frosting suppression operation method. The proposed novel frosting suppression evaluation method is simple and easy to implement, which could contribute to further guiding manufacturers to improve the frosting suppression performance of VS ASHPs.</div></div>","PeriodicalId":11641,"journal":{"name":"Energy and Buildings","volume":"325 ","pages":"Article 115047"},"PeriodicalIF":6.6000,"publicationDate":"2024-11-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluation method and enhanced strategy for frosting suppression performance of variable speed air source heat pump based on frosting suppression performance map\",\"authors\":\"Yao Lin ,&nbsp;Jianfei Luo ,&nbsp;Qing Luo ,&nbsp;Xiaoli Li ,&nbsp;Wei Wang ,&nbsp;Yuying Sun\",\"doi\":\"10.1016/j.enbuild.2024.115047\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>It is well established that the configuration and operation of variable speed air source heat pumps (VS ASHPs) can significantly influence their frosting performance. However, there is currently no effective method to conveniently and accurately evaluate the frosting suppression performance of these units. This paper addresses this gap by proposing a novel evaluation method based on a frosting suppression map for VS ASHPs. Firstly, an experimental setup with four ASHP units and developed frosting suppression maps is described. Second, a method for evaluating the frosting suppression performance of VS ASHP is developed based on the map. Thirdly, a comprehensive evaluation of the frosting suppression performance of the experimental unit is carried out. It is shown that the <em>β</em> values of the four units under the constitutive configuration were 0.74, 0.12, 0.21, and 0.52, and the frosting suppression performance was evaluated as Good, Poor, Fair, and Average, respectively. It could be enhanced and improved to 0.89 (Excellent), 0.24 (Fair), 0.64 (Good), and 0.63 (Good) after applying the frosting suppression operation method. The proposed novel frosting suppression evaluation method is simple and easy to implement, which could contribute to further guiding manufacturers to improve the frosting suppression performance of VS ASHPs.</div></div>\",\"PeriodicalId\":11641,\"journal\":{\"name\":\"Energy and Buildings\",\"volume\":\"325 \",\"pages\":\"Article 115047\"},\"PeriodicalIF\":6.6000,\"publicationDate\":\"2024-11-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Energy and Buildings\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0378778824011630\",\"RegionNum\":2,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CONSTRUCTION & BUILDING TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Energy and Buildings","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0378778824011630","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

众所周知,变速空气源热泵(VS ASHPs)的配置和运行会极大地影响其结霜性能。然而,目前还没有有效的方法来方便、准确地评估这些设备的结霜抑制性能。本文针对这一缺陷,提出了一种基于 VS ASHPs 结霜抑制图的新型评估方法。首先,介绍了四台 ASHP 设备的实验装置和开发的结霜抑制图。其次,基于该地图开发了一种评估 VS ASHP 结霜抑制性能的方法。第三,对实验机组的结霜抑制性能进行了综合评估。结果表明,四台机组在构成配置下的β值分别为0.74、0.12、0.21和0.52,抑霜性能分别被评价为好、差、一般和平均。在应用霜冻抑制操作方法后,其性能可提高并改善至 0.89(优)、0.24(一般)、0.64(良)和 0.63(好)。所提出的新型结霜抑制评价方法简单易行,有助于进一步指导制造商提高 VS ASHPs 的结霜抑制性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Evaluation method and enhanced strategy for frosting suppression performance of variable speed air source heat pump based on frosting suppression performance map
It is well established that the configuration and operation of variable speed air source heat pumps (VS ASHPs) can significantly influence their frosting performance. However, there is currently no effective method to conveniently and accurately evaluate the frosting suppression performance of these units. This paper addresses this gap by proposing a novel evaluation method based on a frosting suppression map for VS ASHPs. Firstly, an experimental setup with four ASHP units and developed frosting suppression maps is described. Second, a method for evaluating the frosting suppression performance of VS ASHP is developed based on the map. Thirdly, a comprehensive evaluation of the frosting suppression performance of the experimental unit is carried out. It is shown that the β values of the four units under the constitutive configuration were 0.74, 0.12, 0.21, and 0.52, and the frosting suppression performance was evaluated as Good, Poor, Fair, and Average, respectively. It could be enhanced and improved to 0.89 (Excellent), 0.24 (Fair), 0.64 (Good), and 0.63 (Good) after applying the frosting suppression operation method. The proposed novel frosting suppression evaluation method is simple and easy to implement, which could contribute to further guiding manufacturers to improve the frosting suppression performance of VS ASHPs.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Energy and Buildings
Energy and Buildings 工程技术-工程:土木
CiteScore
12.70
自引率
11.90%
发文量
863
审稿时长
38 days
期刊介绍: An international journal devoted to investigations of energy use and efficiency in buildings Energy and Buildings is an international journal publishing articles with explicit links to energy use in buildings. The aim is to present new research results, and new proven practice aimed at reducing the energy needs of a building and improving indoor environment quality.
期刊最新文献
Automatic building energy model development and debugging using large language models agentic workflow Early-stage identification of indoor leakage sources in factories Physics-consistent input convex neural network-driven reinforcement learning control for multi-zone radiant ceiling heating and cooling systems: An experimental study Optimizing energy efficiency in buildings’ cold water systems: A differential pressure control-based global approach Cement-MgO synergetic stabilized earth-straw mix: From material performance to building simulation
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1