经皮心室辅助装置的装置相关不良事件和流量容量。

IF 3.9 2区 医学 Q1 CARDIAC & CARDIOVASCULAR SYSTEMS European Heart Journal: Acute Cardiovascular Care Pub Date : 2024-11-19 DOI:10.1093/ehjacc/zuae132
Yuki Ikeda, Shunsuke Ishii, Shohei Nakahara, Saeko Iikura, Teppei Fujita, Yuichiro Iida, Takeru Nabeta, Nobuhiro Sato, Junya Ako
{"title":"经皮心室辅助装置的装置相关不良事件和流量容量。","authors":"Yuki Ikeda, Shunsuke Ishii, Shohei Nakahara, Saeko Iikura, Teppei Fujita, Yuichiro Iida, Takeru Nabeta, Nobuhiro Sato, Junya Ako","doi":"10.1093/ehjacc/zuae132","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Complication management is crucial in patients receiving mechanical circulatory devices. However, there are limited data on the association between the risks of complications and device type in patients with percutaneous ventricular assist devices (PVAD).</p><p><strong>Methods: </strong>The Japanese registry for PVAD (J-PVAD) is a nationwide ongoing registry that enrolls consecutive patients with cardiogenic shock treated with PVAD. We analyzed 5717 patients in the J-PVAD from February 1, 2020, to December 31, 2022, to compare the incident risks of device-related problems and all-cause mortality within 30 days after PVAD introduction based on flow capacities of first-line PVAD (low: Impella 2.5/CP, n=5375; high: Impella 5.0/5.5, n=342).</p><p><strong>Results: </strong>The overall incidence of major device-related problems, including hemolysis, major bleeding, kidney injury, sepsis, and pump stop were 13%, 21%, 7%, 3%, and 1%, respectively. The all-cause mortality rate was 34%. The incident risks of hemolysis (hazard ratio [HR] 0.38, 95% confidence interval [CI] 0.24-0.58), kidney injury (HR 0.32, 95%CI 0.18-0.57), and pump stop (HR 0.38, 95%CI 0.16-0.91) were lower in patients with high-flow PVAD compared with those with low-flow PVAD. The risks of major bleeding or sepsis did not differ significantly between groups. The risk of all-cause mortality was lower in patients with high-flow PVAD compared with those with low-flow PVAD (HR 0.79, 95%CI 0.65-0.96).</p><p><strong>Conclusions: </strong>Compared with those with low-flow PVAD, patients with high-flow PVAD had lower incident risks of device-related problems, including hemolysis, kidney injury, and pump stop, as well as lower risk of all-cause mortality.</p>","PeriodicalId":11861,"journal":{"name":"European Heart Journal: Acute Cardiovascular Care","volume":" ","pages":""},"PeriodicalIF":3.9000,"publicationDate":"2024-11-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Device-Related Adverse Events and Flow Capacity of Percutaneous Ventricular Assist Devices.\",\"authors\":\"Yuki Ikeda, Shunsuke Ishii, Shohei Nakahara, Saeko Iikura, Teppei Fujita, Yuichiro Iida, Takeru Nabeta, Nobuhiro Sato, Junya Ako\",\"doi\":\"10.1093/ehjacc/zuae132\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Complication management is crucial in patients receiving mechanical circulatory devices. However, there are limited data on the association between the risks of complications and device type in patients with percutaneous ventricular assist devices (PVAD).</p><p><strong>Methods: </strong>The Japanese registry for PVAD (J-PVAD) is a nationwide ongoing registry that enrolls consecutive patients with cardiogenic shock treated with PVAD. We analyzed 5717 patients in the J-PVAD from February 1, 2020, to December 31, 2022, to compare the incident risks of device-related problems and all-cause mortality within 30 days after PVAD introduction based on flow capacities of first-line PVAD (low: Impella 2.5/CP, n=5375; high: Impella 5.0/5.5, n=342).</p><p><strong>Results: </strong>The overall incidence of major device-related problems, including hemolysis, major bleeding, kidney injury, sepsis, and pump stop were 13%, 21%, 7%, 3%, and 1%, respectively. The all-cause mortality rate was 34%. The incident risks of hemolysis (hazard ratio [HR] 0.38, 95% confidence interval [CI] 0.24-0.58), kidney injury (HR 0.32, 95%CI 0.18-0.57), and pump stop (HR 0.38, 95%CI 0.16-0.91) were lower in patients with high-flow PVAD compared with those with low-flow PVAD. The risks of major bleeding or sepsis did not differ significantly between groups. The risk of all-cause mortality was lower in patients with high-flow PVAD compared with those with low-flow PVAD (HR 0.79, 95%CI 0.65-0.96).</p><p><strong>Conclusions: </strong>Compared with those with low-flow PVAD, patients with high-flow PVAD had lower incident risks of device-related problems, including hemolysis, kidney injury, and pump stop, as well as lower risk of all-cause mortality.</p>\",\"PeriodicalId\":11861,\"journal\":{\"name\":\"European Heart Journal: Acute Cardiovascular Care\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":3.9000,\"publicationDate\":\"2024-11-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"European Heart Journal: Acute Cardiovascular Care\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1093/ehjacc/zuae132\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Heart Journal: Acute Cardiovascular Care","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1093/ehjacc/zuae132","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

摘要

背景:并发症管理对接受机械循环装置的患者至关重要。然而,关于经皮心室辅助装置(PVAD)患者并发症风险与装置类型之间关系的数据十分有限:日本 PVAD 登记处(J-PVAD)是一个全国性的持续登记处,登记了接受 PVAD 治疗的连续心源性休克患者。我们分析了2020年2月1日至2022年12月31日期间J-PVAD的5717名患者,根据一线PVAD(低:Impella 2.5/CP,n=5375;高:Impella 5.0/5.5,n=342)的流量能力,比较了PVAD使用后30天内发生设备相关问题和全因死亡的风险:结果:与设备相关的主要问题,包括溶血、大出血、肾损伤、败血症和泵停转的总发生率分别为13%、21%、7%、3%和1%。全因死亡率为 34%。与低流量 PVAD 患者相比,高流量 PVAD 患者发生溶血(危险比 [HR] 0.38,95% 置信区间 [CI] 0.24-0.58)、肾损伤(HR 0.32,95%CI 0.18-0.57)和停泵(HR 0.38,95%CI 0.16-0.91)的风险较低。大出血或败血症的风险在不同组间没有显著差异。高流量 PVAD 患者的全因死亡风险低于低流量 PVAD 患者(HR 0.79,95%CI 0.65-0.96):结论:与低流量 PVAD 患者相比,高流量 PVAD 患者发生设备相关问题(包括溶血、肾损伤和泵停转)的风险较低,全因死亡风险也较低。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Device-Related Adverse Events and Flow Capacity of Percutaneous Ventricular Assist Devices.

Background: Complication management is crucial in patients receiving mechanical circulatory devices. However, there are limited data on the association between the risks of complications and device type in patients with percutaneous ventricular assist devices (PVAD).

Methods: The Japanese registry for PVAD (J-PVAD) is a nationwide ongoing registry that enrolls consecutive patients with cardiogenic shock treated with PVAD. We analyzed 5717 patients in the J-PVAD from February 1, 2020, to December 31, 2022, to compare the incident risks of device-related problems and all-cause mortality within 30 days after PVAD introduction based on flow capacities of first-line PVAD (low: Impella 2.5/CP, n=5375; high: Impella 5.0/5.5, n=342).

Results: The overall incidence of major device-related problems, including hemolysis, major bleeding, kidney injury, sepsis, and pump stop were 13%, 21%, 7%, 3%, and 1%, respectively. The all-cause mortality rate was 34%. The incident risks of hemolysis (hazard ratio [HR] 0.38, 95% confidence interval [CI] 0.24-0.58), kidney injury (HR 0.32, 95%CI 0.18-0.57), and pump stop (HR 0.38, 95%CI 0.16-0.91) were lower in patients with high-flow PVAD compared with those with low-flow PVAD. The risks of major bleeding or sepsis did not differ significantly between groups. The risk of all-cause mortality was lower in patients with high-flow PVAD compared with those with low-flow PVAD (HR 0.79, 95%CI 0.65-0.96).

Conclusions: Compared with those with low-flow PVAD, patients with high-flow PVAD had lower incident risks of device-related problems, including hemolysis, kidney injury, and pump stop, as well as lower risk of all-cause mortality.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
8.50
自引率
4.90%
发文量
325
期刊介绍: The European Heart Journal - Acute Cardiovascular Care (EHJ-ACVC) offers a unique integrative approach by combining the expertise of the different sub specialties of cardiology, emergency and intensive care medicine in the management of patients with acute cardiovascular syndromes. Reading through the journal, cardiologists and all other healthcare professionals can access continuous updates that may help them to improve the quality of care and the outcome for patients with acute cardiovascular diseases.
期刊最新文献
Device-Related Adverse Events and Flow Capacity of Percutaneous Ventricular Assist Devices. The future for cardiogenic shock management - Insights from the leaders of the ESC. Echocardiographic Assessment of Right Ventricular Adaptation and Pulmonary Embolism: A Perfect Couple? High VExUS grades are linked to cardiac function in general ICU patients. The microcirculation in cardiogenic shock.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1