{"title":"开发并验证一种稳健的 RP-HPLC 方法,用于定量检测含有氨基酸添加剂的药物制剂中残留的 2-巯基乙胺。","authors":"Delaney Doran, Geoffrey Struble, Katarina Moravcevic, Pinger Wang, Shelly Ji","doi":"10.1016/j.jchromb.2024.124379","DOIUrl":null,"url":null,"abstract":"<p><p>Bispecific antibodies have a wide range of applications in cancer immunotherapy, some of which are manufactured by controlled Fab-arm exchange requiring the reductant 2-mercaptoethylamine (2-MEA). As a process impurity, monitoring the residual 2-MEA in bispecific antibody drug product process development is needed. A novel reversed phase-high performance liquid chromatography (RP-HPLC) method for measurement of residual 2-MEA that uses 7-fluorobenzofurazan-4-sulfonic acid ammonium salt (SBD-F) as a fluorescent-detection tag in drug product formulations containing high concentrations of arginine has been developed. Using a thiol tag for residual 2-MEA eliminates any potential interference from conventional tag binding to amine groups of the formulation arginine, and potentially resulting in overestimation of the amount of impurity in a given sample. The new method has been fully validated for specificity, linearity, accuracy, range, limit of quantitation, limit of detection, and robustness. This method therefore has potential to aid in detecting residual 2-MEA content for any process that utilizes 2-MEA for bispecific antibody manufacturing.</p>","PeriodicalId":348,"journal":{"name":"Journal of Chromatography B","volume":"1249 ","pages":"124379"},"PeriodicalIF":2.8000,"publicationDate":"2024-11-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Development and validation of a robust RP-HPLC method to quantitate residual 2-mercaptoethylamine in drug product formulations containing amino acid additives.\",\"authors\":\"Delaney Doran, Geoffrey Struble, Katarina Moravcevic, Pinger Wang, Shelly Ji\",\"doi\":\"10.1016/j.jchromb.2024.124379\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Bispecific antibodies have a wide range of applications in cancer immunotherapy, some of which are manufactured by controlled Fab-arm exchange requiring the reductant 2-mercaptoethylamine (2-MEA). As a process impurity, monitoring the residual 2-MEA in bispecific antibody drug product process development is needed. A novel reversed phase-high performance liquid chromatography (RP-HPLC) method for measurement of residual 2-MEA that uses 7-fluorobenzofurazan-4-sulfonic acid ammonium salt (SBD-F) as a fluorescent-detection tag in drug product formulations containing high concentrations of arginine has been developed. Using a thiol tag for residual 2-MEA eliminates any potential interference from conventional tag binding to amine groups of the formulation arginine, and potentially resulting in overestimation of the amount of impurity in a given sample. The new method has been fully validated for specificity, linearity, accuracy, range, limit of quantitation, limit of detection, and robustness. This method therefore has potential to aid in detecting residual 2-MEA content for any process that utilizes 2-MEA for bispecific antibody manufacturing.</p>\",\"PeriodicalId\":348,\"journal\":{\"name\":\"Journal of Chromatography B\",\"volume\":\"1249 \",\"pages\":\"124379\"},\"PeriodicalIF\":2.8000,\"publicationDate\":\"2024-11-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Chromatography B\",\"FirstCategoryId\":\"1\",\"ListUrlMain\":\"https://doi.org/10.1016/j.jchromb.2024.124379\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"BIOCHEMICAL RESEARCH METHODS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Chromatography B","FirstCategoryId":"1","ListUrlMain":"https://doi.org/10.1016/j.jchromb.2024.124379","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
Development and validation of a robust RP-HPLC method to quantitate residual 2-mercaptoethylamine in drug product formulations containing amino acid additives.
Bispecific antibodies have a wide range of applications in cancer immunotherapy, some of which are manufactured by controlled Fab-arm exchange requiring the reductant 2-mercaptoethylamine (2-MEA). As a process impurity, monitoring the residual 2-MEA in bispecific antibody drug product process development is needed. A novel reversed phase-high performance liquid chromatography (RP-HPLC) method for measurement of residual 2-MEA that uses 7-fluorobenzofurazan-4-sulfonic acid ammonium salt (SBD-F) as a fluorescent-detection tag in drug product formulations containing high concentrations of arginine has been developed. Using a thiol tag for residual 2-MEA eliminates any potential interference from conventional tag binding to amine groups of the formulation arginine, and potentially resulting in overestimation of the amount of impurity in a given sample. The new method has been fully validated for specificity, linearity, accuracy, range, limit of quantitation, limit of detection, and robustness. This method therefore has potential to aid in detecting residual 2-MEA content for any process that utilizes 2-MEA for bispecific antibody manufacturing.
期刊介绍:
The Journal of Chromatography B publishes papers on developments in separation science relevant to biology and biomedical research including both fundamental advances and applications. Analytical techniques which may be considered include the various facets of chromatography, electrophoresis and related methods, affinity and immunoaffinity-based methodologies, hyphenated and other multi-dimensional techniques, and microanalytical approaches. The journal also considers articles reporting developments in sample preparation, detection techniques including mass spectrometry, and data handling and analysis.
Developments related to preparative separations for the isolation and purification of components of biological systems may be published, including chromatographic and electrophoretic methods, affinity separations, field flow fractionation and other preparative approaches.
Applications to the analysis of biological systems and samples will be considered when the analytical science contains a significant element of novelty, e.g. a new approach to the separation of a compound, novel combination of analytical techniques, or significantly improved analytical performance.