Kyle W Morse, Tejas Subramanian, Eric Zhao, Omri Maayan, Yousi Oquendo, Catherine Himo Gang, James Dowdell, Sheeraz Qureshi, Sravisht Iyer
{"title":"与透视和计算机断层扫描技术相比,机器人辅助导航在单层经椎间孔腰椎椎体融合术中可减轻外科医生的脑力劳动负担:一项非随机前瞻性对照试验。","authors":"Kyle W Morse, Tejas Subramanian, Eric Zhao, Omri Maayan, Yousi Oquendo, Catherine Himo Gang, James Dowdell, Sheeraz Qureshi, Sravisht Iyer","doi":"10.1177/15563316241281064","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Pedicle screw placement during spine fusion is physically and mentally demanding for surgeons. Consequently, spine surgeons can become fatigued, which has implications for both patient safety and surgeon well-being.</p><p><strong>Purpose: </strong>We sought to assess the cognitive workload of surgeons placing pedicle screws using robotic-assisted navigation compared with fluoroscopic and computed tomography (CT)-assisted placement.</p><p><strong>Methods: </strong>We performed a nonrandomized prospective controlled trial to compare the cognitive workload of 3 surgeons performing single-level minimally invasive transforaminal lumbar interbody fusion (MI-TLIF) using robotic, CT, or fluoroscopic navigation on 25 patients (15 in the robotic navigation group and 10 in the nonrobotic group). Immediately after each procedure, surgeons submitted the National Aeronautics and Space Administration-Task Load Index (NASA-TLX), which has 6 subscales: mental demands, physical demands, temporal demands, performance, effort, and frustration. Four tasks associated with pedicle screw placement were assessed independently: (1) screw planning, (2) calibrating robot/obtaining imaging/registration, (3) pedicle cannulation, and (4) screw placement. Patient demographics and surgical characteristics were obtained and reviewed.</p><p><strong>Results: </strong>Surgeons' self-reported cognitive workload was significantly reduced when using robotic-assisted navigation versus CT/fluoroscopic navigation. Workload was reduced for screw planning, pedicle cannulation, and screw placement. In addition, there were significant reductions in each subdomain for these 3 tasks, encompassing mental demand, physical demand, temporal demand, effort, and frustration with improved task performance.</p><p><strong>Conclusions: </strong>This study found significant reductions in mental workload with improved perceived performance for robotic-assisted pedicle screw placement compared with fluoroscopic and CT-navigation techniques. Lowering the cognitive burden associated with screw placement may allow surgeons to address the remainder of the operative case with less decision fatigue, prevent complications, and increase surgeon wellness.</p>","PeriodicalId":35357,"journal":{"name":"Hss Journal","volume":" ","pages":"15563316241281064"},"PeriodicalIF":1.6000,"publicationDate":"2024-10-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11572391/pdf/","citationCount":"0","resultStr":"{\"title\":\"Robotic-Assisted Navigation in Single-Level Transforaminal Lumbar Interbody Fusion Reduces Surgeons' Mental Workload Compared With Fluoroscopic and Computed Tomographic Techniques: A Nonrandomized Prospective Controlled Trial.\",\"authors\":\"Kyle W Morse, Tejas Subramanian, Eric Zhao, Omri Maayan, Yousi Oquendo, Catherine Himo Gang, James Dowdell, Sheeraz Qureshi, Sravisht Iyer\",\"doi\":\"10.1177/15563316241281064\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Pedicle screw placement during spine fusion is physically and mentally demanding for surgeons. Consequently, spine surgeons can become fatigued, which has implications for both patient safety and surgeon well-being.</p><p><strong>Purpose: </strong>We sought to assess the cognitive workload of surgeons placing pedicle screws using robotic-assisted navigation compared with fluoroscopic and computed tomography (CT)-assisted placement.</p><p><strong>Methods: </strong>We performed a nonrandomized prospective controlled trial to compare the cognitive workload of 3 surgeons performing single-level minimally invasive transforaminal lumbar interbody fusion (MI-TLIF) using robotic, CT, or fluoroscopic navigation on 25 patients (15 in the robotic navigation group and 10 in the nonrobotic group). Immediately after each procedure, surgeons submitted the National Aeronautics and Space Administration-Task Load Index (NASA-TLX), which has 6 subscales: mental demands, physical demands, temporal demands, performance, effort, and frustration. Four tasks associated with pedicle screw placement were assessed independently: (1) screw planning, (2) calibrating robot/obtaining imaging/registration, (3) pedicle cannulation, and (4) screw placement. Patient demographics and surgical characteristics were obtained and reviewed.</p><p><strong>Results: </strong>Surgeons' self-reported cognitive workload was significantly reduced when using robotic-assisted navigation versus CT/fluoroscopic navigation. Workload was reduced for screw planning, pedicle cannulation, and screw placement. In addition, there were significant reductions in each subdomain for these 3 tasks, encompassing mental demand, physical demand, temporal demand, effort, and frustration with improved task performance.</p><p><strong>Conclusions: </strong>This study found significant reductions in mental workload with improved perceived performance for robotic-assisted pedicle screw placement compared with fluoroscopic and CT-navigation techniques. Lowering the cognitive burden associated with screw placement may allow surgeons to address the remainder of the operative case with less decision fatigue, prevent complications, and increase surgeon wellness.</p>\",\"PeriodicalId\":35357,\"journal\":{\"name\":\"Hss Journal\",\"volume\":\" \",\"pages\":\"15563316241281064\"},\"PeriodicalIF\":1.6000,\"publicationDate\":\"2024-10-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11572391/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Hss Journal\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1177/15563316241281064\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Hss Journal","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/15563316241281064","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
Robotic-Assisted Navigation in Single-Level Transforaminal Lumbar Interbody Fusion Reduces Surgeons' Mental Workload Compared With Fluoroscopic and Computed Tomographic Techniques: A Nonrandomized Prospective Controlled Trial.
Background: Pedicle screw placement during spine fusion is physically and mentally demanding for surgeons. Consequently, spine surgeons can become fatigued, which has implications for both patient safety and surgeon well-being.
Purpose: We sought to assess the cognitive workload of surgeons placing pedicle screws using robotic-assisted navigation compared with fluoroscopic and computed tomography (CT)-assisted placement.
Methods: We performed a nonrandomized prospective controlled trial to compare the cognitive workload of 3 surgeons performing single-level minimally invasive transforaminal lumbar interbody fusion (MI-TLIF) using robotic, CT, or fluoroscopic navigation on 25 patients (15 in the robotic navigation group and 10 in the nonrobotic group). Immediately after each procedure, surgeons submitted the National Aeronautics and Space Administration-Task Load Index (NASA-TLX), which has 6 subscales: mental demands, physical demands, temporal demands, performance, effort, and frustration. Four tasks associated with pedicle screw placement were assessed independently: (1) screw planning, (2) calibrating robot/obtaining imaging/registration, (3) pedicle cannulation, and (4) screw placement. Patient demographics and surgical characteristics were obtained and reviewed.
Results: Surgeons' self-reported cognitive workload was significantly reduced when using robotic-assisted navigation versus CT/fluoroscopic navigation. Workload was reduced for screw planning, pedicle cannulation, and screw placement. In addition, there were significant reductions in each subdomain for these 3 tasks, encompassing mental demand, physical demand, temporal demand, effort, and frustration with improved task performance.
Conclusions: This study found significant reductions in mental workload with improved perceived performance for robotic-assisted pedicle screw placement compared with fluoroscopic and CT-navigation techniques. Lowering the cognitive burden associated with screw placement may allow surgeons to address the remainder of the operative case with less decision fatigue, prevent complications, and increase surgeon wellness.
期刊介绍:
The HSS Journal is the Musculoskeletal Journal of Hospital for Special Surgery. The aim of the HSS Journal is to promote cutting edge research, clinical pathways, and state-of-the-art techniques that inform and facilitate the continuing education of the orthopaedic and musculoskeletal communities. HSS Journal publishes articles that offer contributions to the advancement of the knowledge of musculoskeletal diseases and encourages submission of manuscripts from all musculoskeletal disciplines.