近视屈光手术候选者的屈光不正、轴向长度和轴向长度-角膜曲率比与眼前节生物测量的差异相关性。

Jian Zhang, Youlin Zhu, Ping Yuan, Xiaojuan Dong, Manyun Xie, Zongrui Ma, Rong Tian
{"title":"近视屈光手术候选者的屈光不正、轴向长度和轴向长度-角膜曲率比与眼前节生物测量的差异相关性。","authors":"Jian Zhang, Youlin Zhu, Ping Yuan, Xiaojuan Dong, Manyun Xie, Zongrui Ma, Rong Tian","doi":"10.1016/j.pdpdt.2024.104408","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To investigate the correlations of spherical equivalent (SE), axial length (AL), and AL to corneal curvature radius ratio (AL/CR) with anterior segment biometrics in candidates for myopic refractive surgery.</p><p><strong>Methods: </strong>Anterior segment biometrics of 2,478 myopic refractive surgery candidates measured by Pentacam were collected retrospectively. The anterior segment biometrics included anterior corneal curvature (ACC), posterior corneal curvature (PCC), white-to-white corneal diameter (WTW), central corneal thickness (CCT), corneal volume at 3mm (CV), anterior corneal astigmatism (ACA), posterior corneal astigmatism (PCA), anterior corneal eccentricity (ACE), posterior corneal eccentricity (PCE), anterior corneal asphericity (ACAP), posterior corneal asphericity (PCAP), anterior chamber depth (ACD), and anterior chamber volume (ACV). The eyes were divided into four groups according to the AL: group 1, AL≤24mm; group 2, 24mm<AL≤26mm; group 3, 26mm<AL≤28mm; group 4, AL≥28mm. The correlations between these biometrics with SE, AL, and AL/CR were assessed by Pearson or Spearman correlation tests. A correlation with a coefficient ≥0.3 and a p value <0.05 were considered significant.</p><p><strong>Results: </strong>In all AL groups, ACC was positively correlated with SE (r = 0.446 to 0.620) and negatively correlated with AL/CR (r = -0.704 to -0.894), whereas PCC was positively correlated with SE (r = 0.394 to 0.612) and negatively correlated with AL/CR (r = -0.606 to -0.787). WTW was positively correlated with SE (r = 0.304 to 0.474) in every group, and negatively correlated with AL/CR (r = -0.405 and -0.412) in group 1 and 4. ACA was positively correlated with AL (r = 0.310) and AL/CR (r = -0.333) in group 4. ACD was negatively correlated with AL (r = -0.304) in group 4, and positively correlated with AL/CR (r = -0.325) in group 2. ACV was positively correlated with SE (r = 0.344) in group 4, and positively correlated with AL (r = 0.303) in group 2. CCT, CV, PCA, ACE, PCE, ACAP, and PCAP was not significantly correlated with SE, AL, or AL/CR in any of group.</p><p><strong>Conclusions: </strong>Differential correlations were observed between anterior segment biometrics and SE, AL, and AL/CR, suggesting that various myopia indicators have different effects on ocular structures. These findings may help identify the ocular structures that can be targeted of refractive surgery.</p>","PeriodicalId":94170,"journal":{"name":"Photodiagnosis and photodynamic therapy","volume":" ","pages":"104408"},"PeriodicalIF":0.0000,"publicationDate":"2024-11-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Differential correlations of refractive error, axial length, and axial length-to-corneal curvature ratio with anterior segment biometrics in myopic refractive surgery candidates.\",\"authors\":\"Jian Zhang, Youlin Zhu, Ping Yuan, Xiaojuan Dong, Manyun Xie, Zongrui Ma, Rong Tian\",\"doi\":\"10.1016/j.pdpdt.2024.104408\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To investigate the correlations of spherical equivalent (SE), axial length (AL), and AL to corneal curvature radius ratio (AL/CR) with anterior segment biometrics in candidates for myopic refractive surgery.</p><p><strong>Methods: </strong>Anterior segment biometrics of 2,478 myopic refractive surgery candidates measured by Pentacam were collected retrospectively. The anterior segment biometrics included anterior corneal curvature (ACC), posterior corneal curvature (PCC), white-to-white corneal diameter (WTW), central corneal thickness (CCT), corneal volume at 3mm (CV), anterior corneal astigmatism (ACA), posterior corneal astigmatism (PCA), anterior corneal eccentricity (ACE), posterior corneal eccentricity (PCE), anterior corneal asphericity (ACAP), posterior corneal asphericity (PCAP), anterior chamber depth (ACD), and anterior chamber volume (ACV). The eyes were divided into four groups according to the AL: group 1, AL≤24mm; group 2, 24mm<AL≤26mm; group 3, 26mm<AL≤28mm; group 4, AL≥28mm. The correlations between these biometrics with SE, AL, and AL/CR were assessed by Pearson or Spearman correlation tests. A correlation with a coefficient ≥0.3 and a p value <0.05 were considered significant.</p><p><strong>Results: </strong>In all AL groups, ACC was positively correlated with SE (r = 0.446 to 0.620) and negatively correlated with AL/CR (r = -0.704 to -0.894), whereas PCC was positively correlated with SE (r = 0.394 to 0.612) and negatively correlated with AL/CR (r = -0.606 to -0.787). WTW was positively correlated with SE (r = 0.304 to 0.474) in every group, and negatively correlated with AL/CR (r = -0.405 and -0.412) in group 1 and 4. ACA was positively correlated with AL (r = 0.310) and AL/CR (r = -0.333) in group 4. ACD was negatively correlated with AL (r = -0.304) in group 4, and positively correlated with AL/CR (r = -0.325) in group 2. ACV was positively correlated with SE (r = 0.344) in group 4, and positively correlated with AL (r = 0.303) in group 2. CCT, CV, PCA, ACE, PCE, ACAP, and PCAP was not significantly correlated with SE, AL, or AL/CR in any of group.</p><p><strong>Conclusions: </strong>Differential correlations were observed between anterior segment biometrics and SE, AL, and AL/CR, suggesting that various myopia indicators have different effects on ocular structures. These findings may help identify the ocular structures that can be targeted of refractive surgery.</p>\",\"PeriodicalId\":94170,\"journal\":{\"name\":\"Photodiagnosis and photodynamic therapy\",\"volume\":\" \",\"pages\":\"104408\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-11-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Photodiagnosis and photodynamic therapy\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1016/j.pdpdt.2024.104408\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Photodiagnosis and photodynamic therapy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1016/j.pdpdt.2024.104408","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目的:研究近视屈光手术候选者的球面等值(SE)、轴向长度(AL)、AL 与角膜曲率半径比(AL/CR)与眼前节生物测量的相关性:回顾性收集了 2,478 名近视屈光手术候选者通过 Pentacam 测量的前段生物测量数据。前段生物测量包括角膜前曲率 (ACC)、角膜后曲率 (PCC)、角膜白对白直径 (WTW)、角膜中央厚度 (CCT)、3 毫米处角膜体积 (CV)、角膜前散光 (ACA)、角膜后散光 (ACA)、角膜后散光(PCA)、角膜前偏心率(ACE)、角膜后偏心率(PCE)、角膜前非球面度(ACAP)、角膜后非球面度(PCAP)、前房深度(ACD)和前房容积(ACV)。根据AL将眼睛分为四组:第一组,AL≤24mm;第二组,24mm结果:在所有 AL 组中,ACC 与 SE 呈正相关(r = 0.446 至 0.620),与 AL/CR 呈负相关(r = -0.704 至 -0.894),而 PCC 与 SE 呈正相关(r = 0.394 至 0.612),与 AL/CR 呈负相关(r = -0.606 至 -0.787)。在各组中,WTW 与 SE 呈正相关(r = 0.304 至 0.474),而在第 1 组和第 4 组中,WTW 与 AL/CR 呈负相关(r = -0.405 和 -0.412)。第 4 组中,ACA 与 AL(r = 0.310)和 AL/CR (r = -0.333)呈正相关。 第 4 组中,ACD 与 AL(r = -0.304)呈负相关,第 2 组中,ACD 与 AL/CR (r = -0.325)呈正相关。在第 4 组中,ACV 与 SE 呈正相关(r = 0.344),在第 2 组中,ACV 与 AL 呈正相关(r = 0.303)。各组的 CCT、CV、PCA、ACE、PCE、ACAP 和 PCAP 与 SE、AL 或 AL/CR 均无明显相关性:结论:观察到眼前节生物测量指标与SE、AL和AL/CR之间存在不同的相关性,这表明各种近视指标对眼部结构有不同的影响。这些发现可能有助于确定屈光手术的目标眼部结构。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Differential correlations of refractive error, axial length, and axial length-to-corneal curvature ratio with anterior segment biometrics in myopic refractive surgery candidates.

Purpose: To investigate the correlations of spherical equivalent (SE), axial length (AL), and AL to corneal curvature radius ratio (AL/CR) with anterior segment biometrics in candidates for myopic refractive surgery.

Methods: Anterior segment biometrics of 2,478 myopic refractive surgery candidates measured by Pentacam were collected retrospectively. The anterior segment biometrics included anterior corneal curvature (ACC), posterior corneal curvature (PCC), white-to-white corneal diameter (WTW), central corneal thickness (CCT), corneal volume at 3mm (CV), anterior corneal astigmatism (ACA), posterior corneal astigmatism (PCA), anterior corneal eccentricity (ACE), posterior corneal eccentricity (PCE), anterior corneal asphericity (ACAP), posterior corneal asphericity (PCAP), anterior chamber depth (ACD), and anterior chamber volume (ACV). The eyes were divided into four groups according to the AL: group 1, AL≤24mm; group 2, 24mm

Results: In all AL groups, ACC was positively correlated with SE (r = 0.446 to 0.620) and negatively correlated with AL/CR (r = -0.704 to -0.894), whereas PCC was positively correlated with SE (r = 0.394 to 0.612) and negatively correlated with AL/CR (r = -0.606 to -0.787). WTW was positively correlated with SE (r = 0.304 to 0.474) in every group, and negatively correlated with AL/CR (r = -0.405 and -0.412) in group 1 and 4. ACA was positively correlated with AL (r = 0.310) and AL/CR (r = -0.333) in group 4. ACD was negatively correlated with AL (r = -0.304) in group 4, and positively correlated with AL/CR (r = -0.325) in group 2. ACV was positively correlated with SE (r = 0.344) in group 4, and positively correlated with AL (r = 0.303) in group 2. CCT, CV, PCA, ACE, PCE, ACAP, and PCAP was not significantly correlated with SE, AL, or AL/CR in any of group.

Conclusions: Differential correlations were observed between anterior segment biometrics and SE, AL, and AL/CR, suggesting that various myopia indicators have different effects on ocular structures. These findings may help identify the ocular structures that can be targeted of refractive surgery.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Comparison of fluorescence intensity of protoporphyrin IX as observed on the screen of different cystoscopic systems. Changes in retinal microvasculature and serum Gremlin-1 levels in acromegaly: a case-control study. Evaluation of efficacy of Hemoporfin-PDT in the treatment of PWS birthmarks of young children previously received PDL treatment. Photodynamic disruption of a polymicrobial biofilm of two periodontal species using indocyanine green-loaded nanospheres. Bleaching efficacy of in-office bleaching with violet light using low-concentration hydrogen peroxide nanoparticulate photocatalyst gel: a randomized controlled trial.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1