通过分析方法研究被动式太阳能建筑中加入 PCM 的三层围护结构在不同气候条件下的室内热条件

IF 9.9 1区 工程技术 Q1 ENERGY & FUELS Energy Conversion and Management Pub Date : 2024-11-20 DOI:10.1016/j.enconman.2024.119276
Teng Guo, Guochen Sang, Yangkai Zhang, Pengyang Cai, Xiaoling Cui, Zhixuan Wang
{"title":"通过分析方法研究被动式太阳能建筑中加入 PCM 的三层围护结构在不同气候条件下的室内热条件","authors":"Teng Guo,&nbsp;Guochen Sang,&nbsp;Yangkai Zhang,&nbsp;Pengyang Cai,&nbsp;Xiaoling Cui,&nbsp;Zhixuan Wang","doi":"10.1016/j.enconman.2024.119276","DOIUrl":null,"url":null,"abstract":"<div><div>Clarifying the thermal mechanism of buildings provides a basis for the scientific design and optimization of envelopes. This study explored the mechanism of outdoor thermal disturbances, thermal storage materials, the building noumenon and internal heat sources (IHS) affecting indoor thermal conditions (ITC) by analytical method. The triple envelope incorporated with phase change material (EIPCM) form of “outer insulation layer + structural layer + inner PCM layer” was determined and theoretically derived a predictive model of the indoor thermal conditions (PMITC) to evaluate thermal comfort in five representative regions of northwest China. Following that analyzed the significance of the influencing factors on ITC employing linear regression. The results illustrated that ITC was mainly affected by the coupling of four aspects factors. More in detail, solar radiation entering the room exploited the most prominent effect on the increase in average indoor temperature. PCM layer only affected the temperature amplitude but not the average indoor temperature. The sensible heat storage of the structural layer had a weaker effect on ITC than the PCM layer. The lowest temperatures in Yinchuan and Xi’an were both above 16 °C, while Urumqi had a higher temperature fluctuation of 2.1  °C and an average indoor temperature of 6.32 °C lower than Xi’an. Based on the estimate of ITC and degree hours (DH), the application effects of PCM in buildings in five regions can be summarized as complete thermal comfort (Yinchuan and Xi’an), partial thermal comfort (Lanzhou and Xining) and complete thermal discomfort (Urumqi). For the different factors that affected ITC, the window-to-wall ratio (WWR) had the highest coefficient of determination exceeding 93 % and the building dimension performed the lowest around 26 %.</div></div>","PeriodicalId":11664,"journal":{"name":"Energy Conversion and Management","volume":"323 ","pages":"Article 119276"},"PeriodicalIF":9.9000,"publicationDate":"2024-11-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Study on indoor thermal conditions of a triple envelope incorporated with PCM in the passive solar building under different climates by analytical method\",\"authors\":\"Teng Guo,&nbsp;Guochen Sang,&nbsp;Yangkai Zhang,&nbsp;Pengyang Cai,&nbsp;Xiaoling Cui,&nbsp;Zhixuan Wang\",\"doi\":\"10.1016/j.enconman.2024.119276\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>Clarifying the thermal mechanism of buildings provides a basis for the scientific design and optimization of envelopes. This study explored the mechanism of outdoor thermal disturbances, thermal storage materials, the building noumenon and internal heat sources (IHS) affecting indoor thermal conditions (ITC) by analytical method. The triple envelope incorporated with phase change material (EIPCM) form of “outer insulation layer + structural layer + inner PCM layer” was determined and theoretically derived a predictive model of the indoor thermal conditions (PMITC) to evaluate thermal comfort in five representative regions of northwest China. Following that analyzed the significance of the influencing factors on ITC employing linear regression. The results illustrated that ITC was mainly affected by the coupling of four aspects factors. More in detail, solar radiation entering the room exploited the most prominent effect on the increase in average indoor temperature. PCM layer only affected the temperature amplitude but not the average indoor temperature. The sensible heat storage of the structural layer had a weaker effect on ITC than the PCM layer. The lowest temperatures in Yinchuan and Xi’an were both above 16 °C, while Urumqi had a higher temperature fluctuation of 2.1  °C and an average indoor temperature of 6.32 °C lower than Xi’an. Based on the estimate of ITC and degree hours (DH), the application effects of PCM in buildings in five regions can be summarized as complete thermal comfort (Yinchuan and Xi’an), partial thermal comfort (Lanzhou and Xining) and complete thermal discomfort (Urumqi). For the different factors that affected ITC, the window-to-wall ratio (WWR) had the highest coefficient of determination exceeding 93 % and the building dimension performed the lowest around 26 %.</div></div>\",\"PeriodicalId\":11664,\"journal\":{\"name\":\"Energy Conversion and Management\",\"volume\":\"323 \",\"pages\":\"Article 119276\"},\"PeriodicalIF\":9.9000,\"publicationDate\":\"2024-11-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Energy Conversion and Management\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0196890424012172\",\"RegionNum\":1,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ENERGY & FUELS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Energy Conversion and Management","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0196890424012172","RegionNum":1,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENERGY & FUELS","Score":null,"Total":0}
引用次数: 0

摘要

厘清建筑物的热机理为科学设计和优化围护结构提供了基础。本研究通过分析方法探讨了室外热扰动、蓄热材料、建筑本体和内部热源(IHS)对室内热条件(ITC)的影响机理。确定了 "外保温层 + 结构层 + 内 PCM 层 "的相变材料三重围护结构(EIPCM)形式,并从理论上推导出室内热工条件预测模型(PMITC),以评估中国西北五个代表性地区的热舒适性。随后,利用线性回归分析了影响因素对 ITC 的显著性。结果表明,ITC 主要受四个方面因素的耦合影响。具体而言,进入室内的太阳辐射对室内平均温度的升高影响最为显著。PCM 层只影响温度幅度,而不影响室内平均温度。与 PCM 层相比,结构层的显热储存对 ITC 的影响较弱。银川和西安的最低气温均高于 16 °C,而乌鲁木齐的气温波动较大,为 2.1 °C,室内平均气温比西安低 6.32 °C。根据对 ITC 和度小时(DH)的估算,PCM 在五个地区建筑中的应用效果可概括为完全热舒适(银川和西安)、部分热舒适(兰州和西宁)和完全热不适(乌鲁木齐)。在影响 ITC 的不同因素中,窗墙比(WWR)的决定系数最高,超过 93%,建筑尺寸的决定系数最低,约为 26%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Study on indoor thermal conditions of a triple envelope incorporated with PCM in the passive solar building under different climates by analytical method
Clarifying the thermal mechanism of buildings provides a basis for the scientific design and optimization of envelopes. This study explored the mechanism of outdoor thermal disturbances, thermal storage materials, the building noumenon and internal heat sources (IHS) affecting indoor thermal conditions (ITC) by analytical method. The triple envelope incorporated with phase change material (EIPCM) form of “outer insulation layer + structural layer + inner PCM layer” was determined and theoretically derived a predictive model of the indoor thermal conditions (PMITC) to evaluate thermal comfort in five representative regions of northwest China. Following that analyzed the significance of the influencing factors on ITC employing linear regression. The results illustrated that ITC was mainly affected by the coupling of four aspects factors. More in detail, solar radiation entering the room exploited the most prominent effect on the increase in average indoor temperature. PCM layer only affected the temperature amplitude but not the average indoor temperature. The sensible heat storage of the structural layer had a weaker effect on ITC than the PCM layer. The lowest temperatures in Yinchuan and Xi’an were both above 16 °C, while Urumqi had a higher temperature fluctuation of 2.1  °C and an average indoor temperature of 6.32 °C lower than Xi’an. Based on the estimate of ITC and degree hours (DH), the application effects of PCM in buildings in five regions can be summarized as complete thermal comfort (Yinchuan and Xi’an), partial thermal comfort (Lanzhou and Xining) and complete thermal discomfort (Urumqi). For the different factors that affected ITC, the window-to-wall ratio (WWR) had the highest coefficient of determination exceeding 93 % and the building dimension performed the lowest around 26 %.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Energy Conversion and Management
Energy Conversion and Management 工程技术-力学
CiteScore
19.00
自引率
11.50%
发文量
1304
审稿时长
17 days
期刊介绍: The journal Energy Conversion and Management provides a forum for publishing original contributions and comprehensive technical review articles of interdisciplinary and original research on all important energy topics. The topics considered include energy generation, utilization, conversion, storage, transmission, conservation, management and sustainability. These topics typically involve various types of energy such as mechanical, thermal, nuclear, chemical, electromagnetic, magnetic and electric. These energy types cover all known energy resources, including renewable resources (e.g., solar, bio, hydro, wind, geothermal and ocean energy), fossil fuels and nuclear resources.
期刊最新文献
Stabilizing ignition and enhancing combustion within pre-chamber jet by integrating microwave-assisted ignition A novel high-speed homogenizer assisted process intensification technique for biodiesel production using soya acid oil: Process optimization, kinetic and thermodynamic modelling Development of a novel tool to simulate solar thermal cogeneration plants using small-capacity tower plants The effects of the location of the leading-edge tubercles on the performance of horizontal axis wind turbine Dual-mode arrayed vibration-wind piezoelectric energy harvester
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1