老年人股骨近端骨折。骨水泥增量是否能减少机械故障并增加功能?一项回顾性队列研究。

IF 2.2 3区 医学 Q3 CRITICAL CARE MEDICINE Injury-International Journal of the Care of the Injured Pub Date : 2024-10-01 DOI:10.1016/j.injury.2024.111673
Héctor J Aguado , Sergio País-Ortega , Virginia García-Virto , Patricia Bodas-Gallego , Aranzazu Álvarez-Ramos , Abel Ganso , María Plata-García , María Macho-Mier , Ester Rodríguez-García , Belén García-Medrano , David C. Noriega
{"title":"老年人股骨近端骨折。骨水泥增量是否能减少机械故障并增加功能?一项回顾性队列研究。","authors":"Héctor J Aguado ,&nbsp;Sergio País-Ortega ,&nbsp;Virginia García-Virto ,&nbsp;Patricia Bodas-Gallego ,&nbsp;Aranzazu Álvarez-Ramos ,&nbsp;Abel Ganso ,&nbsp;María Plata-García ,&nbsp;María Macho-Mier ,&nbsp;Ester Rodríguez-García ,&nbsp;Belén García-Medrano ,&nbsp;David C. Noriega","doi":"10.1016/j.injury.2024.111673","DOIUrl":null,"url":null,"abstract":"<div><h3>Introduction</h3><div>The management of extracapsular proximal femoral fractures (EPFF) with intramedullary nails in the elderly is hindered by osteoporosis, leading to complications that significantly impact functionality due to restrictions for full weight-bearing. We hypothesized that cement augmentation of the cephalic blade could enhance the bone-implant interface and reduce mechanical failure, thereby improving patient functionality in the management of EPFF.</div></div><div><h3>Materials and methods</h3><div>A retrospective cohort study was conducted on patients ≥ 70 years old with type 31-A EPFF (AO/OTA classification) treated with intramedullary nailing between 2017 and 2021, with and without cephalic blade augmentation with bone cement. Evaluation included demographic, clinical/functional parameters, complications, mortality, and radiological assessment (tip-apex distance (TAD), position of the helical blade, cut-out, cut-through, and any fixation failure).</div></div><div><h3>Results</h3><div>Fifty-eight patients were included, with 30 in the augmented group and 28 in the non-augmented group, with a median age of 88 and 86 years, respectively (<em>p</em> = 0.143), and a median follow-up of 17.9 and 18.2 months, respectively (<em>p</em> = 0.395). Both groups were comparable in terms of sex, Charlson Comorbidity Index, place of residence, pre-fracture mobility, and fracture stability. However, the non-augmented group showed worse ASA grade and pre-fracture cognitive status (<em>p</em> = 0.043). The most common position of the blade was center-center in both groups (96.7 % and 82.1 %, respectively) (<em>p</em> = 0.201). The mean TAD was 15.09 mm (±4.35) in the study group and 16.97 mm (±6.57) in the control group (<em>p</em> = 0.213). At one-year follow-up, there were no differences in medical complications (26.7 % and 28.6 %) (<em>p</em> = 1), surgical complications (6.7 % and 10.7 %) (<em>p</em> = 0.462), mortality (33.3 % and 21.4 %) (<em>p</em> = 0.385), or mechanical failure (0 % and 7.1 %) (<em>p</em> = 0.229). In the augmented group, one patient had intra-articular cement leak and implant infection, and a second patient presented avascular necrosis. In the non-augmented group, there was one periprosthetic fracture, one cut-out and one cut-through.</div></div><div><h3>Conclusions</h3><div>Cement augmentation in EPFF management does not improve functional outcomes or reduce mechanical complications. Furthermore, augmentation did not affect fracture reduction or the position of the helical blade in the head, nor was it associated with an increase in medical complications. However, augmentation can be considered a safe technique.</div></div><div><h3>Level of evidence</h3><div>Level IV.</div></div>","PeriodicalId":54978,"journal":{"name":"Injury-International Journal of the Care of the Injured","volume":"55 ","pages":"Article 111673"},"PeriodicalIF":2.2000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Proximal femoral fractures in the elderly. Does cement augmentation decrease mechanical failures and increase function? A retrospective cohort study\",\"authors\":\"Héctor J Aguado ,&nbsp;Sergio País-Ortega ,&nbsp;Virginia García-Virto ,&nbsp;Patricia Bodas-Gallego ,&nbsp;Aranzazu Álvarez-Ramos ,&nbsp;Abel Ganso ,&nbsp;María Plata-García ,&nbsp;María Macho-Mier ,&nbsp;Ester Rodríguez-García ,&nbsp;Belén García-Medrano ,&nbsp;David C. Noriega\",\"doi\":\"10.1016/j.injury.2024.111673\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Introduction</h3><div>The management of extracapsular proximal femoral fractures (EPFF) with intramedullary nails in the elderly is hindered by osteoporosis, leading to complications that significantly impact functionality due to restrictions for full weight-bearing. We hypothesized that cement augmentation of the cephalic blade could enhance the bone-implant interface and reduce mechanical failure, thereby improving patient functionality in the management of EPFF.</div></div><div><h3>Materials and methods</h3><div>A retrospective cohort study was conducted on patients ≥ 70 years old with type 31-A EPFF (AO/OTA classification) treated with intramedullary nailing between 2017 and 2021, with and without cephalic blade augmentation with bone cement. Evaluation included demographic, clinical/functional parameters, complications, mortality, and radiological assessment (tip-apex distance (TAD), position of the helical blade, cut-out, cut-through, and any fixation failure).</div></div><div><h3>Results</h3><div>Fifty-eight patients were included, with 30 in the augmented group and 28 in the non-augmented group, with a median age of 88 and 86 years, respectively (<em>p</em> = 0.143), and a median follow-up of 17.9 and 18.2 months, respectively (<em>p</em> = 0.395). Both groups were comparable in terms of sex, Charlson Comorbidity Index, place of residence, pre-fracture mobility, and fracture stability. However, the non-augmented group showed worse ASA grade and pre-fracture cognitive status (<em>p</em> = 0.043). The most common position of the blade was center-center in both groups (96.7 % and 82.1 %, respectively) (<em>p</em> = 0.201). The mean TAD was 15.09 mm (±4.35) in the study group and 16.97 mm (±6.57) in the control group (<em>p</em> = 0.213). At one-year follow-up, there were no differences in medical complications (26.7 % and 28.6 %) (<em>p</em> = 1), surgical complications (6.7 % and 10.7 %) (<em>p</em> = 0.462), mortality (33.3 % and 21.4 %) (<em>p</em> = 0.385), or mechanical failure (0 % and 7.1 %) (<em>p</em> = 0.229). In the augmented group, one patient had intra-articular cement leak and implant infection, and a second patient presented avascular necrosis. In the non-augmented group, there was one periprosthetic fracture, one cut-out and one cut-through.</div></div><div><h3>Conclusions</h3><div>Cement augmentation in EPFF management does not improve functional outcomes or reduce mechanical complications. Furthermore, augmentation did not affect fracture reduction or the position of the helical blade in the head, nor was it associated with an increase in medical complications. However, augmentation can be considered a safe technique.</div></div><div><h3>Level of evidence</h3><div>Level IV.</div></div>\",\"PeriodicalId\":54978,\"journal\":{\"name\":\"Injury-International Journal of the Care of the Injured\",\"volume\":\"55 \",\"pages\":\"Article 111673\"},\"PeriodicalIF\":2.2000,\"publicationDate\":\"2024-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Injury-International Journal of the Care of the Injured\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0020138324003796\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CRITICAL CARE MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Injury-International Journal of the Care of the Injured","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0020138324003796","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CRITICAL CARE MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

简介:骨质疏松症阻碍了用髓内钉治疗老年人股骨近端囊外骨折(EPFF),导致并发症,由于完全负重受到限制,严重影响了患者的功能。我们假设头骨刀片的骨水泥增量可以增强骨-植入物界面并减少机械故障,从而在治疗 EPFF 时改善患者的功能:对2017年至2021年间接受髓内钉治疗的年龄≥70岁的31-A型EPFF(AO/OTA分类)患者进行了一项回顾性队列研究,包括使用或不使用骨水泥增强头骨刃的患者。评估内容包括人口统计学、临床/功能参数、并发症、死亡率和放射学评估(尖端-外端距离(TAD)、螺旋叶片的位置、切口、切透和任何固定失败):共纳入 58 名患者,其中增强组 30 人,非增强组 28 人,中位年龄分别为 88 岁和 86 岁(P = 0.143),中位随访时间分别为 17.9 个月和 18.2 个月(P = 0.395)。两组患者在性别、查尔森综合症指数、居住地、骨折前活动能力和骨折稳定性方面具有可比性。然而,非增强组的 ASA 分级和骨折前认知状态较差(P = 0.043)。两组最常见的刀片位置都是居中(分别为 96.7% 和 82.1%)(p = 0.201)。研究组的平均 TAD 为 15.09 毫米(±4.35),对照组为 16.97 毫米(±6.57)(p = 0.213)。在一年的随访中,医疗并发症(26.7% 和 28.6%)(p = 1)、手术并发症(6.7% 和 10.7%)(p = 0.462)、死亡率(33.3% 和 21.4%)(p = 0.385)或机械故障(0% 和 7.1%)(p = 0.229)均无差异。在增强组中,一名患者出现关节内骨水泥渗漏和植入物感染,另一名患者出现血管性坏死。非增强组中,一名患者出现假体周围骨折,一名患者出现切口,一名患者出现切穿:结论:在EPFF治疗中植入骨水泥并不能改善功能性结果或减少机械性并发症。此外,增量并不会影响骨折的复位或螺旋刀片在头部的位置,也不会增加医疗并发症。不过,可以认为增量技术是一种安全的技术:证据等级:IV级。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Proximal femoral fractures in the elderly. Does cement augmentation decrease mechanical failures and increase function? A retrospective cohort study

Introduction

The management of extracapsular proximal femoral fractures (EPFF) with intramedullary nails in the elderly is hindered by osteoporosis, leading to complications that significantly impact functionality due to restrictions for full weight-bearing. We hypothesized that cement augmentation of the cephalic blade could enhance the bone-implant interface and reduce mechanical failure, thereby improving patient functionality in the management of EPFF.

Materials and methods

A retrospective cohort study was conducted on patients ≥ 70 years old with type 31-A EPFF (AO/OTA classification) treated with intramedullary nailing between 2017 and 2021, with and without cephalic blade augmentation with bone cement. Evaluation included demographic, clinical/functional parameters, complications, mortality, and radiological assessment (tip-apex distance (TAD), position of the helical blade, cut-out, cut-through, and any fixation failure).

Results

Fifty-eight patients were included, with 30 in the augmented group and 28 in the non-augmented group, with a median age of 88 and 86 years, respectively (p = 0.143), and a median follow-up of 17.9 and 18.2 months, respectively (p = 0.395). Both groups were comparable in terms of sex, Charlson Comorbidity Index, place of residence, pre-fracture mobility, and fracture stability. However, the non-augmented group showed worse ASA grade and pre-fracture cognitive status (p = 0.043). The most common position of the blade was center-center in both groups (96.7 % and 82.1 %, respectively) (p = 0.201). The mean TAD was 15.09 mm (±4.35) in the study group and 16.97 mm (±6.57) in the control group (p = 0.213). At one-year follow-up, there were no differences in medical complications (26.7 % and 28.6 %) (p = 1), surgical complications (6.7 % and 10.7 %) (p = 0.462), mortality (33.3 % and 21.4 %) (p = 0.385), or mechanical failure (0 % and 7.1 %) (p = 0.229). In the augmented group, one patient had intra-articular cement leak and implant infection, and a second patient presented avascular necrosis. In the non-augmented group, there was one periprosthetic fracture, one cut-out and one cut-through.

Conclusions

Cement augmentation in EPFF management does not improve functional outcomes or reduce mechanical complications. Furthermore, augmentation did not affect fracture reduction or the position of the helical blade in the head, nor was it associated with an increase in medical complications. However, augmentation can be considered a safe technique.

Level of evidence

Level IV.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
4.00
自引率
8.00%
发文量
699
审稿时长
96 days
期刊介绍: Injury was founded in 1969 and is an international journal dealing with all aspects of trauma care and accident surgery. Our primary aim is to facilitate the exchange of ideas, techniques and information among all members of the trauma team.
期刊最新文献
Does injury type influence patient preference, response rates, and data completeness for online or telephone follow-up following injury? Post-operative periprosthetic femoral fractures in England: patient profiles and short-term outcomes Pancreaticoduodenectomy in high-grade pancreatic and duodenal trauma The Influence of Nerve Surgical Techniques at Time of Amputation on the Prevalence of Heterotopic Ossification in Transtibial Amputees Perceived barriers and facilitators to implementation of injury prevention programs in the military: feedback from inside the trenches
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1