大型公共场所吸入病原体气溶胶的严重程度和风险:多地点释放下的芳草地医院的启示

IF 12.2 1区 环境科学与生态学 Q1 ENGINEERING, ENVIRONMENTAL Journal of Hazardous Materials Pub Date : 2024-11-27 DOI:10.1016/j.jhazmat.2024.136695
Chuan Jiang, Zhijian Liu, Yongxin Wang, Guangpeng Yao, Junzhou He, Shiyue Li, Rui Rong, Zhenyu Liang, Jingwei Liu
{"title":"大型公共场所吸入病原体气溶胶的严重程度和风险:多地点释放下的芳草地医院的启示","authors":"Chuan Jiang, Zhijian Liu, Yongxin Wang, Guangpeng Yao, Junzhou He, Shiyue Li, Rui Rong, Zhenyu Liang, Jingwei Liu","doi":"10.1016/j.jhazmat.2024.136695","DOIUrl":null,"url":null,"abstract":"The key to strengthening the inherent safety of large public spaces and implementing precise preventive measures lies in clarifying the transmission risks of respiratory infectious diseases based on multiple factors. This work innovatively improves a pathogen inhalation infection risk prediction model and attempts to apply it to a Fangcang Shelter Hospital to investigate the effect of pathogen release location on risk distribution and the role of airflow distribution in risk control mechanisms. The model used in the study improved in resolution and accuracy, shedding light on the airflow distribution mechanisms involved in pathogen transport and risk control, thus providing a quantitatively realistic landscape of the spread of respiratory infectious diseases in large indoor environments. Predictions reveal a significant unevenness in the spatial distribution of infection probabilities within the multi-patient shelter unit, which is further exacerbated by different release locations, and that extreme infection risks can reach 4 to 14 times the average. Additionally, the study noted that the infection probability in the medical staff area due to the long-distance transmission of contaminants can reach as high as 1.72% and that patients from ward 6# could potentially infect a healthcare worker every four days.","PeriodicalId":361,"journal":{"name":"Journal of Hazardous Materials","volume":"63 1","pages":""},"PeriodicalIF":12.2000,"publicationDate":"2024-11-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Severity and risk to inhalation of pathogen-laden aerosol in large public spaces: Insights from Fangcang Shelter Hospitals under multi-location release\",\"authors\":\"Chuan Jiang, Zhijian Liu, Yongxin Wang, Guangpeng Yao, Junzhou He, Shiyue Li, Rui Rong, Zhenyu Liang, Jingwei Liu\",\"doi\":\"10.1016/j.jhazmat.2024.136695\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The key to strengthening the inherent safety of large public spaces and implementing precise preventive measures lies in clarifying the transmission risks of respiratory infectious diseases based on multiple factors. This work innovatively improves a pathogen inhalation infection risk prediction model and attempts to apply it to a Fangcang Shelter Hospital to investigate the effect of pathogen release location on risk distribution and the role of airflow distribution in risk control mechanisms. The model used in the study improved in resolution and accuracy, shedding light on the airflow distribution mechanisms involved in pathogen transport and risk control, thus providing a quantitatively realistic landscape of the spread of respiratory infectious diseases in large indoor environments. Predictions reveal a significant unevenness in the spatial distribution of infection probabilities within the multi-patient shelter unit, which is further exacerbated by different release locations, and that extreme infection risks can reach 4 to 14 times the average. Additionally, the study noted that the infection probability in the medical staff area due to the long-distance transmission of contaminants can reach as high as 1.72% and that patients from ward 6# could potentially infect a healthcare worker every four days.\",\"PeriodicalId\":361,\"journal\":{\"name\":\"Journal of Hazardous Materials\",\"volume\":\"63 1\",\"pages\":\"\"},\"PeriodicalIF\":12.2000,\"publicationDate\":\"2024-11-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Hazardous Materials\",\"FirstCategoryId\":\"93\",\"ListUrlMain\":\"https://doi.org/10.1016/j.jhazmat.2024.136695\",\"RegionNum\":1,\"RegionCategory\":\"环境科学与生态学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ENGINEERING, ENVIRONMENTAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Hazardous Materials","FirstCategoryId":"93","ListUrlMain":"https://doi.org/10.1016/j.jhazmat.2024.136695","RegionNum":1,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, ENVIRONMENTAL","Score":null,"Total":0}
引用次数: 0

摘要

加强大型公共场所的本质安全,实施精准的预防措施,关键在于基于多种因素明确呼吸道传染病的传播风险。本研究创新性地改进了病原体吸入感染风险预测模型,并尝试将其应用于防空洞医院,研究病原体释放位置对风险分布的影响,以及气流分布在风险控制机制中的作用。研究中使用的模型提高了分辨率和准确性,揭示了病原体传播和风险控制中的气流分布机制,从而为呼吸道传染病在大型室内环境中的传播提供了定量的真实景观。预测结果显示,在多病人收容单位内,感染概率的空间分布存在明显的不均匀性,而不同的释放地点又进一步加剧了这种不均匀性,极端感染风险可达到平均值的 4 到 14 倍。此外,研究还指出,由于污染物的远距离传播,医务人员区域的感染概率可高达 1.72%,6#病房的病人每四天就有可能感染一名医护人员。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Severity and risk to inhalation of pathogen-laden aerosol in large public spaces: Insights from Fangcang Shelter Hospitals under multi-location release
The key to strengthening the inherent safety of large public spaces and implementing precise preventive measures lies in clarifying the transmission risks of respiratory infectious diseases based on multiple factors. This work innovatively improves a pathogen inhalation infection risk prediction model and attempts to apply it to a Fangcang Shelter Hospital to investigate the effect of pathogen release location on risk distribution and the role of airflow distribution in risk control mechanisms. The model used in the study improved in resolution and accuracy, shedding light on the airflow distribution mechanisms involved in pathogen transport and risk control, thus providing a quantitatively realistic landscape of the spread of respiratory infectious diseases in large indoor environments. Predictions reveal a significant unevenness in the spatial distribution of infection probabilities within the multi-patient shelter unit, which is further exacerbated by different release locations, and that extreme infection risks can reach 4 to 14 times the average. Additionally, the study noted that the infection probability in the medical staff area due to the long-distance transmission of contaminants can reach as high as 1.72% and that patients from ward 6# could potentially infect a healthcare worker every four days.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Hazardous Materials
Journal of Hazardous Materials 工程技术-工程:环境
CiteScore
25.40
自引率
5.90%
发文量
3059
审稿时长
58 days
期刊介绍: The Journal of Hazardous Materials serves as a global platform for promoting cutting-edge research in the field of Environmental Science and Engineering. Our publication features a wide range of articles, including full-length research papers, review articles, and perspectives, with the aim of enhancing our understanding of the dangers and risks associated with various materials concerning public health and the environment. It is important to note that the term "environmental contaminants" refers specifically to substances that pose hazardous effects through contamination, while excluding those that do not have such impacts on the environment or human health. Moreover, we emphasize the distinction between wastes and hazardous materials in order to provide further clarity on the scope of the journal. We have a keen interest in exploring specific compounds and microbial agents that have adverse effects on the environment.
期刊最新文献
How Heatwaves Impact Microalgae in the Presence of Environmentally Relevant PFAS Concentration: Metabolic Shifts and Challenges Posed Severity and risk to inhalation of pathogen-laden aerosol in large public spaces: Insights from Fangcang Shelter Hospitals under multi-location release Rapid Capture Perfluorooctanoic Acid and Perfluorooctane Sulfonate at Environmentally Relevant Concentrations via the ‘mesh trap’ of Triazine-Based Polymer Network: Mechanism and Photocatalytic regeneration Integrating isotope mixing and hydrologic models towards a more accurate riverine nitrate source apportionment Reduction of microbial load in soil by gas generated using non-thermal atmospheric pressure plasma
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1