Wenzheng Xiong, Florian Zirpel, M Zameel Cader, Daniel C Anthony, Fay Probert
{"title":"脑活检 NMR 代谢组学的提取方法:平衡代谢物稳定性和蛋白质沉淀。","authors":"Wenzheng Xiong, Florian Zirpel, M Zameel Cader, Daniel C Anthony, Fay Probert","doi":"10.3390/metabo14110609","DOIUrl":null,"url":null,"abstract":"<p><p><b>Background/Objectives</b>: Metabolic profiling of tissue samples via liquid-state nuclear magnetic resonance (NMR) requires the extraction of polar metabolites in a suitable deuterated solvent. Such methods often prioritise metabolite recovery over protein removal due to the relatively low sensitivity of NMR metabolomics and the routine use of methods able to supress residual protein signals. However, residual protein may impact metabolite integrity and the metabolite stability after NMR sample preparation is often overlooked. This study aimed to investigate the effect of residual protein contamination in rodent brain extracts and identify a reproducible extraction method that optimises metabolite recovery while ensuring sample stability. <b>Methods</b>: The performance of acetonitrile/water (50-100% MeCN), methanol/water (50-100% MeOH), and methanol/water/chloroform (MeOH/H<sub>2</sub>O/CHCl<sub>3</sub>) were assessed for extraction efficiency, reproducibility, residual protein contamination, and metabolite stability up to eight hours post NMR sample preparation. <b>Results</b>: Aspartate and glutamate deuteration were observed in 50% MeCN, 50% MeOH, and 67% MeOH extractions along with the conversion of N-acetyl aspartate to aspartate and acetate in 50% MeCN and 50% MeOH extractions. Both observations correlated with residual protein contamination and, thus, are a result of inadequate protein precipitation, as confirmed by ultrafiltration. MeOH/H<sub>2</sub>O/CHCl<sub>3</sub> extraction preserved the stability of these metabolites while maintaining good extraction efficiency and reproducibility. <b>Conclusions</b>: Thus, we recommend MeOH/H<sub>2</sub>O/CHCl<sub>3</sub> extraction for untargeted brain NMR metabolic profiling due to its effective protein precipitation and reliable performance. Nonetheless, the performance of detecting metabolites prone to oxidation such as ascorbate and glutathione is not improved by this method.</p>","PeriodicalId":18496,"journal":{"name":"Metabolites","volume":"14 11","pages":""},"PeriodicalIF":3.4000,"publicationDate":"2024-11-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11596573/pdf/","citationCount":"0","resultStr":"{\"title\":\"Extraction Methods for Brain Biopsy NMR Metabolomics: Balancing Metabolite Stability and Protein Precipitation.\",\"authors\":\"Wenzheng Xiong, Florian Zirpel, M Zameel Cader, Daniel C Anthony, Fay Probert\",\"doi\":\"10.3390/metabo14110609\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><b>Background/Objectives</b>: Metabolic profiling of tissue samples via liquid-state nuclear magnetic resonance (NMR) requires the extraction of polar metabolites in a suitable deuterated solvent. Such methods often prioritise metabolite recovery over protein removal due to the relatively low sensitivity of NMR metabolomics and the routine use of methods able to supress residual protein signals. However, residual protein may impact metabolite integrity and the metabolite stability after NMR sample preparation is often overlooked. This study aimed to investigate the effect of residual protein contamination in rodent brain extracts and identify a reproducible extraction method that optimises metabolite recovery while ensuring sample stability. <b>Methods</b>: The performance of acetonitrile/water (50-100% MeCN), methanol/water (50-100% MeOH), and methanol/water/chloroform (MeOH/H<sub>2</sub>O/CHCl<sub>3</sub>) were assessed for extraction efficiency, reproducibility, residual protein contamination, and metabolite stability up to eight hours post NMR sample preparation. <b>Results</b>: Aspartate and glutamate deuteration were observed in 50% MeCN, 50% MeOH, and 67% MeOH extractions along with the conversion of N-acetyl aspartate to aspartate and acetate in 50% MeCN and 50% MeOH extractions. Both observations correlated with residual protein contamination and, thus, are a result of inadequate protein precipitation, as confirmed by ultrafiltration. MeOH/H<sub>2</sub>O/CHCl<sub>3</sub> extraction preserved the stability of these metabolites while maintaining good extraction efficiency and reproducibility. <b>Conclusions</b>: Thus, we recommend MeOH/H<sub>2</sub>O/CHCl<sub>3</sub> extraction for untargeted brain NMR metabolic profiling due to its effective protein precipitation and reliable performance. Nonetheless, the performance of detecting metabolites prone to oxidation such as ascorbate and glutathione is not improved by this method.</p>\",\"PeriodicalId\":18496,\"journal\":{\"name\":\"Metabolites\",\"volume\":\"14 11\",\"pages\":\"\"},\"PeriodicalIF\":3.4000,\"publicationDate\":\"2024-11-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11596573/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Metabolites\",\"FirstCategoryId\":\"99\",\"ListUrlMain\":\"https://doi.org/10.3390/metabo14110609\",\"RegionNum\":3,\"RegionCategory\":\"生物学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"BIOCHEMISTRY & MOLECULAR BIOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Metabolites","FirstCategoryId":"99","ListUrlMain":"https://doi.org/10.3390/metabo14110609","RegionNum":3,"RegionCategory":"生物学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"BIOCHEMISTRY & MOLECULAR BIOLOGY","Score":null,"Total":0}
Extraction Methods for Brain Biopsy NMR Metabolomics: Balancing Metabolite Stability and Protein Precipitation.
Background/Objectives: Metabolic profiling of tissue samples via liquid-state nuclear magnetic resonance (NMR) requires the extraction of polar metabolites in a suitable deuterated solvent. Such methods often prioritise metabolite recovery over protein removal due to the relatively low sensitivity of NMR metabolomics and the routine use of methods able to supress residual protein signals. However, residual protein may impact metabolite integrity and the metabolite stability after NMR sample preparation is often overlooked. This study aimed to investigate the effect of residual protein contamination in rodent brain extracts and identify a reproducible extraction method that optimises metabolite recovery while ensuring sample stability. Methods: The performance of acetonitrile/water (50-100% MeCN), methanol/water (50-100% MeOH), and methanol/water/chloroform (MeOH/H2O/CHCl3) were assessed for extraction efficiency, reproducibility, residual protein contamination, and metabolite stability up to eight hours post NMR sample preparation. Results: Aspartate and glutamate deuteration were observed in 50% MeCN, 50% MeOH, and 67% MeOH extractions along with the conversion of N-acetyl aspartate to aspartate and acetate in 50% MeCN and 50% MeOH extractions. Both observations correlated with residual protein contamination and, thus, are a result of inadequate protein precipitation, as confirmed by ultrafiltration. MeOH/H2O/CHCl3 extraction preserved the stability of these metabolites while maintaining good extraction efficiency and reproducibility. Conclusions: Thus, we recommend MeOH/H2O/CHCl3 extraction for untargeted brain NMR metabolic profiling due to its effective protein precipitation and reliable performance. Nonetheless, the performance of detecting metabolites prone to oxidation such as ascorbate and glutathione is not improved by this method.
MetabolitesBiochemistry, Genetics and Molecular Biology-Molecular Biology
CiteScore
5.70
自引率
7.30%
发文量
1070
审稿时长
17.17 days
期刊介绍:
Metabolites (ISSN 2218-1989) is an international, peer-reviewed open access journal of metabolism and metabolomics. Metabolites publishes original research articles and review articles in all molecular aspects of metabolism relevant to the fields of metabolomics, metabolic biochemistry, computational and systems biology, biotechnology and medicine, with a particular focus on the biological roles of metabolites and small molecule biomarkers. Metabolites encourages scientists to publish their experimental and theoretical results in as much detail as possible. Therefore, there is no restriction on article length. Sufficient experimental details must be provided to enable the results to be accurately reproduced. Electronic material representing additional figures, materials and methods explanation, or supporting results and evidence can be submitted with the main manuscript as supplementary material.