{"title":"结合焦点损失和骰子损失函数可改善中分辨率冷冻电子显微镜密度图中贝塔片的分割。","authors":"Yongcheng Mu, Thu Nguyen, Bryan Hawickhorst, Willy Wriggers, Jiangwen Sun, Jing He","doi":"10.1093/bioadv/vbae169","DOIUrl":null,"url":null,"abstract":"<p><strong>Summary: </strong>Although multiple neural networks have been proposed for detecting secondary structures from medium-resolution (5-10 Å) cryo-electron microscopy (cryo-EM) maps, the loss functions used in the existing deep learning networks are primarily based on cross-entropy loss, which is known to be sensitive to class imbalances. We investigated five loss functions: cross-entropy, Focal loss, Dice loss, and two combined loss functions. Using a U-Net architecture in our DeepSSETracer method and a dataset composed of 1355 box-cropped atomic-structure/density-map pairs, we found that a newly designed loss function that combines Focal loss and Dice loss provides the best overall detection accuracy for secondary structures. For β-sheet voxels, which are generally much harder to detect than helix voxels, the combined loss function achieved a significant improvement (an 8.8% increase in the F<sub>1</sub> score) compared to the cross-entropy loss function and a noticeable improvement from the Dice loss function. This study demonstrates the potential for designing more effective loss functions for hard cases in the segmentation of secondary structures. The newly trained model was incorporated into DeepSSETracer 1.1 for the segmentation of protein secondary structures in medium-resolution cryo-EM map components. DeepSSETracer can be integrated into ChimeraX, a popular molecular visualization software.</p><p><strong>Availability and implementation: </strong>https://www.cs.odu.edu/∼bioinfo/B2I_Tools/.</p>","PeriodicalId":72368,"journal":{"name":"Bioinformatics advances","volume":"4 1","pages":"vbae169"},"PeriodicalIF":2.4000,"publicationDate":"2024-11-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11590252/pdf/","citationCount":"0","resultStr":"{\"title\":\"The combined focal loss and dice loss function improves the segmentation of beta-sheets in medium-resolution cryo-electron-microscopy density maps.\",\"authors\":\"Yongcheng Mu, Thu Nguyen, Bryan Hawickhorst, Willy Wriggers, Jiangwen Sun, Jing He\",\"doi\":\"10.1093/bioadv/vbae169\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Summary: </strong>Although multiple neural networks have been proposed for detecting secondary structures from medium-resolution (5-10 Å) cryo-electron microscopy (cryo-EM) maps, the loss functions used in the existing deep learning networks are primarily based on cross-entropy loss, which is known to be sensitive to class imbalances. We investigated five loss functions: cross-entropy, Focal loss, Dice loss, and two combined loss functions. Using a U-Net architecture in our DeepSSETracer method and a dataset composed of 1355 box-cropped atomic-structure/density-map pairs, we found that a newly designed loss function that combines Focal loss and Dice loss provides the best overall detection accuracy for secondary structures. For β-sheet voxels, which are generally much harder to detect than helix voxels, the combined loss function achieved a significant improvement (an 8.8% increase in the F<sub>1</sub> score) compared to the cross-entropy loss function and a noticeable improvement from the Dice loss function. This study demonstrates the potential for designing more effective loss functions for hard cases in the segmentation of secondary structures. The newly trained model was incorporated into DeepSSETracer 1.1 for the segmentation of protein secondary structures in medium-resolution cryo-EM map components. DeepSSETracer can be integrated into ChimeraX, a popular molecular visualization software.</p><p><strong>Availability and implementation: </strong>https://www.cs.odu.edu/∼bioinfo/B2I_Tools/.</p>\",\"PeriodicalId\":72368,\"journal\":{\"name\":\"Bioinformatics advances\",\"volume\":\"4 1\",\"pages\":\"vbae169\"},\"PeriodicalIF\":2.4000,\"publicationDate\":\"2024-11-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11590252/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Bioinformatics advances\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1093/bioadv/vbae169\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q2\",\"JCRName\":\"MATHEMATICAL & COMPUTATIONAL BIOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bioinformatics advances","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1093/bioadv/vbae169","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"MATHEMATICAL & COMPUTATIONAL BIOLOGY","Score":null,"Total":0}
The combined focal loss and dice loss function improves the segmentation of beta-sheets in medium-resolution cryo-electron-microscopy density maps.
Summary: Although multiple neural networks have been proposed for detecting secondary structures from medium-resolution (5-10 Å) cryo-electron microscopy (cryo-EM) maps, the loss functions used in the existing deep learning networks are primarily based on cross-entropy loss, which is known to be sensitive to class imbalances. We investigated five loss functions: cross-entropy, Focal loss, Dice loss, and two combined loss functions. Using a U-Net architecture in our DeepSSETracer method and a dataset composed of 1355 box-cropped atomic-structure/density-map pairs, we found that a newly designed loss function that combines Focal loss and Dice loss provides the best overall detection accuracy for secondary structures. For β-sheet voxels, which are generally much harder to detect than helix voxels, the combined loss function achieved a significant improvement (an 8.8% increase in the F1 score) compared to the cross-entropy loss function and a noticeable improvement from the Dice loss function. This study demonstrates the potential for designing more effective loss functions for hard cases in the segmentation of secondary structures. The newly trained model was incorporated into DeepSSETracer 1.1 for the segmentation of protein secondary structures in medium-resolution cryo-EM map components. DeepSSETracer can be integrated into ChimeraX, a popular molecular visualization software.
Availability and implementation: https://www.cs.odu.edu/∼bioinfo/B2I_Tools/.