等速测功机对踝关节足底屈肌强度等距评估的可靠性

IF 2.2 3区 医学 Q1 REHABILITATION Physical Therapy in Sport Pub Date : 2024-11-09 DOI:10.1016/j.ptsp.2024.11.001
Fanny-May Santy , Anthony Pernoud , Simon Barrué-Belou , François Fourchet , Hugo Bothorel , Pierre Samozino
{"title":"等速测功机对踝关节足底屈肌强度等距评估的可靠性","authors":"Fanny-May Santy ,&nbsp;Anthony Pernoud ,&nbsp;Simon Barrué-Belou ,&nbsp;François Fourchet ,&nbsp;Hugo Bothorel ,&nbsp;Pierre Samozino","doi":"10.1016/j.ptsp.2024.11.001","DOIUrl":null,"url":null,"abstract":"<div><h3>Objective</h3><div>To evaluate isokinetic dynamometer reliability for isometric assessment of plantar flexor (PF) strength.</div></div><div><h3>Design</h3><div>Cross-sectional.</div></div><div><h3>Setting</h3><div>Testing by the same physiotherapist twice during a first session (repeatability) and once during a second session (reproducibility).</div></div><div><h3>Participants</h3><div>Twenty-two healthy subjects (44 ankles, 11 men/11 women).</div></div><div><h3>Main outcome measures</h3><div>Isometric PF peak torque, with and without body mass normalization, at 0° and +20° of plantar flexion. Measurement reliability was evaluated using intraclass correlation coefficient (ICC), standard error of measurement (SEM) and minimal detectable change (MDC).</div></div><div><h3>Results</h3><div>Without normalization, measurement repeatability was excellent at 0° of plantar flexion (ICC, 0.94; SEM, 6.6%; MDC, 18.4%) compared with good repeatability at +20° (ICC, 0.85; SEM, 11.1%; MDC 30.6%). Measurement repeatability following normalization was good at 0° (ICC, 0.88; SEM, 5.2%; MDC, 14.4%) and +20° (ICC, 0.79; SEM, 10.2%; MDC, 28.1%). While reproducibility was good at 0° with normalization (ICC, 0.84; SEM, 5.9%; MDC, 16.3%) or excellent without (ICC 0.92; SEM 7.5%; MDC, 20.8%), it was moderate at +20° with normalization (ICC 0.71; SEM 11.3%; MDC, 31.3%) or good without (ICC 0.78; SEM 13.0%; MDC, 36.1%).</div></div><div><h3>Conclusion</h3><div>The reliability of PF maximal isometric strength is good/excellent at 0° of plantar flexion but moderate/good at +20°.</div></div>","PeriodicalId":49698,"journal":{"name":"Physical Therapy in Sport","volume":"71 ","pages":"Pages 36-42"},"PeriodicalIF":2.2000,"publicationDate":"2024-11-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Reliability of isokinetic dynamometer for isometric assessment of ankle plantar flexor strength\",\"authors\":\"Fanny-May Santy ,&nbsp;Anthony Pernoud ,&nbsp;Simon Barrué-Belou ,&nbsp;François Fourchet ,&nbsp;Hugo Bothorel ,&nbsp;Pierre Samozino\",\"doi\":\"10.1016/j.ptsp.2024.11.001\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Objective</h3><div>To evaluate isokinetic dynamometer reliability for isometric assessment of plantar flexor (PF) strength.</div></div><div><h3>Design</h3><div>Cross-sectional.</div></div><div><h3>Setting</h3><div>Testing by the same physiotherapist twice during a first session (repeatability) and once during a second session (reproducibility).</div></div><div><h3>Participants</h3><div>Twenty-two healthy subjects (44 ankles, 11 men/11 women).</div></div><div><h3>Main outcome measures</h3><div>Isometric PF peak torque, with and without body mass normalization, at 0° and +20° of plantar flexion. Measurement reliability was evaluated using intraclass correlation coefficient (ICC), standard error of measurement (SEM) and minimal detectable change (MDC).</div></div><div><h3>Results</h3><div>Without normalization, measurement repeatability was excellent at 0° of plantar flexion (ICC, 0.94; SEM, 6.6%; MDC, 18.4%) compared with good repeatability at +20° (ICC, 0.85; SEM, 11.1%; MDC 30.6%). Measurement repeatability following normalization was good at 0° (ICC, 0.88; SEM, 5.2%; MDC, 14.4%) and +20° (ICC, 0.79; SEM, 10.2%; MDC, 28.1%). While reproducibility was good at 0° with normalization (ICC, 0.84; SEM, 5.9%; MDC, 16.3%) or excellent without (ICC 0.92; SEM 7.5%; MDC, 20.8%), it was moderate at +20° with normalization (ICC 0.71; SEM 11.3%; MDC, 31.3%) or good without (ICC 0.78; SEM 13.0%; MDC, 36.1%).</div></div><div><h3>Conclusion</h3><div>The reliability of PF maximal isometric strength is good/excellent at 0° of plantar flexion but moderate/good at +20°.</div></div>\",\"PeriodicalId\":49698,\"journal\":{\"name\":\"Physical Therapy in Sport\",\"volume\":\"71 \",\"pages\":\"Pages 36-42\"},\"PeriodicalIF\":2.2000,\"publicationDate\":\"2024-11-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Physical Therapy in Sport\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1466853X24001147\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"REHABILITATION\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Physical Therapy in Sport","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1466853X24001147","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"REHABILITATION","Score":null,"Total":0}
引用次数: 0

摘要

目的评价等速测功机在足底屈肌(PF)力量等距评估中的可靠性。设置由同一物理治疗师在第一次治疗期间进行两次测试(可重复性),在第二次治疗期间进行一次测试(可重复性)。健康受试者22人(踝关节44人,男11人,女11人)。主要结果测量在足底屈曲0°和+20°时,体重归一化和未归一化时测量PF峰值扭矩。测量信度采用类内相关系数(ICC)、测量标准误差(SEM)和最小可检测变化(MDC)进行评估。结果未经归一化处理,足底屈曲0°时测量的重复性很好(ICC, 0.94;SEM, 6.6%;MDC, 18.4%),与+20°时的良好重复性相比(ICC, 0.85;SEM, 11.1%;争取民主变革运动的30.6%)。归一化后的测量重复性在0°时良好(ICC, 0.88;SEM, 5.2%;MDC, 14.4%)和+20°(ICC, 0.79;SEM, 10.2%;争取民主变革运动,28.1%)。而在0°归一化条件下,重现性良好(ICC, 0.84;SEM, 5.9%;MDC, 16.3%)或excellent without (ICC 0.92;SEM 7.5%;MDC, 20.8%),正常化+20°时为中度(ICC 0.71;SEM 11.3%;MDC, 31.3%)或good without (ICC 0.78;SEM 13.0%;争取民主变革运动,36.1%)。结论PF最大等距强度在足底0°屈曲时可靠性好/优,在+20°屈曲时可靠性一般/好。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Reliability of isokinetic dynamometer for isometric assessment of ankle plantar flexor strength

Objective

To evaluate isokinetic dynamometer reliability for isometric assessment of plantar flexor (PF) strength.

Design

Cross-sectional.

Setting

Testing by the same physiotherapist twice during a first session (repeatability) and once during a second session (reproducibility).

Participants

Twenty-two healthy subjects (44 ankles, 11 men/11 women).

Main outcome measures

Isometric PF peak torque, with and without body mass normalization, at 0° and +20° of plantar flexion. Measurement reliability was evaluated using intraclass correlation coefficient (ICC), standard error of measurement (SEM) and minimal detectable change (MDC).

Results

Without normalization, measurement repeatability was excellent at 0° of plantar flexion (ICC, 0.94; SEM, 6.6%; MDC, 18.4%) compared with good repeatability at +20° (ICC, 0.85; SEM, 11.1%; MDC 30.6%). Measurement repeatability following normalization was good at 0° (ICC, 0.88; SEM, 5.2%; MDC, 14.4%) and +20° (ICC, 0.79; SEM, 10.2%; MDC, 28.1%). While reproducibility was good at 0° with normalization (ICC, 0.84; SEM, 5.9%; MDC, 16.3%) or excellent without (ICC 0.92; SEM 7.5%; MDC, 20.8%), it was moderate at +20° with normalization (ICC 0.71; SEM 11.3%; MDC, 31.3%) or good without (ICC 0.78; SEM 13.0%; MDC, 36.1%).

Conclusion

The reliability of PF maximal isometric strength is good/excellent at 0° of plantar flexion but moderate/good at +20°.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Physical Therapy in Sport
Physical Therapy in Sport 医学-康复医学
CiteScore
4.50
自引率
8.30%
发文量
125
审稿时长
39 days
期刊介绍: Physical Therapy in Sport is an international peer-reviewed journal that provides a forum for the publication of research and clinical practice material relevant to the healthcare professions involved in sports and exercise medicine, and rehabilitation. The journal publishes material that is indispensable for day-to-day practice and continuing professional development. Physical Therapy in Sport covers topics dealing with the diagnosis, treatment, and prevention of injuries, as well as more general areas of sports and exercise medicine and related sports science. The journal publishes original research, case studies, reviews, masterclasses, papers on clinical approaches, and book reviews, as well as occasional reports from conferences. Papers are double-blind peer-reviewed by our international advisory board and other international experts, and submissions from a broad range of disciplines are actively encouraged.
期刊最新文献
A pilot study on the effects of multimodal cervical exercise training on clinical concussion risk factors in female athletes Hip adduction and abduction strength values in NCAA Division I American football players: Strength values and a comparison across position groups The influence of patient gender on exercise prescription in ACL reconstruction rehabilitation Postural control strategies in individuals with and without chronic ankle instability during the reach phase of the posteromedial direction of the star excursion balance test Editorial Board
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1