{"title":"全磁悬浮左心室辅助装置的左心室尺寸和临床结果。","authors":"Ezequiel J Molina, Mustafa M Ahmed, Farooq H Sheikh, Joseph C Cleveland, Daniel J Goldstein, Nir Y Uriel, AiJia Wang, Jordan J Revis, Mandeep R Mehra","doi":"10.1016/j.jchf.2024.09.019","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Prior analyses have suggested that a smaller left ventricular end-diastolic diameter (LVEDD) is associated with reduced survival following HeartMate 3 left ventricular assist device implantation.</p><p><strong>Objectives: </strong>In this trial-based comprehensive analysis, the authors sought to examine clinical characteristics and association with the outcome of this specific relationship.</p><p><strong>Methods: </strong>The authors analyzed the presence of LVEDD <55 mm among 1,921 analyzable HeartMate 3 patients within the MOMENTUM 3 (Multicenter Study of MagLev Technology in Patients Undergoing Mechanical Circulatory Support Therapy With HeartMate 3) trial portfolio, on endpoints of overall survival and adverse events at 2 years. Adverse events included hemocompatibility-related (stroke, bleeding, and pump thrombosis) and non-hemocompatibility-related (right heart failure, infection) outcomes.</p><p><strong>Results: </strong>Those with a smaller LVEDD (<55 mm) (n = 108) were older (age 63 ± 11 years vs 60 ± 12 years; P = 0.005), were more often female (31% vs 20%; P = 0.096), and had more ischemic cardiomyopathy (60.2% vs 42.6%; P = 0.0004) compared with the LVEDD ≥55 mm group (n = 1,813). Death during implant hospitalization was higher (14.8 vs 5.7%; P = 0.0007) and survival at 2 years was lower (63.3% vs 81.8%; HR: 1.97 [95% CI: 1.39-2.79]; P = 0.0002) in the LVEDD <55 mm group. The LVEDD <55 mm group experienced more deaths due to hemocompatibility-related adverse events (2.8% vs 0.6%; HR: 4.61 [95% CI: 1.29-16.45]; P = 0.018) and right heart failure, both early (0-30 days; 7.4% vs 2.0%; HR: 3.70 [95% CI: 1.73-7.91]; P = 0.001) and late (>30 days; 12.0 vs 4.8%; HR: 2.58 [95% CI: 1.37-4.84]; P = 0.003). Low-flow alarms rehospitalizations were higher in the LVEDD <55 mm cohort (17.4 vs 8.3%; HR: 2.39 [95% CI: 1.59-3.59]; P < 0.001).</p><p><strong>Conclusions: </strong>Although infrequent in occurrence, smaller LVEDD (<55 mm) is associated with increased risk for early and late mortality, a consequence of hemocompatibility-related and right heart failure-related deaths. Rehospitalizations due to low-flow alarms are also more frequent. (MOMENTUM 3 IDE Clinical Study Protocol [HM3™]; NCT02224755; MOMENTUM 3 Continued Access Protocol [MOMENTUM 3 CAP]; NCT02892955).</p>","PeriodicalId":14687,"journal":{"name":"JACC. Heart failure","volume":" ","pages":""},"PeriodicalIF":10.3000,"publicationDate":"2024-12-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Left Ventricular Dimensions and Clinical Outcomes With a Fully Magnetically Levitated Left Ventricular Assist Device.\",\"authors\":\"Ezequiel J Molina, Mustafa M Ahmed, Farooq H Sheikh, Joseph C Cleveland, Daniel J Goldstein, Nir Y Uriel, AiJia Wang, Jordan J Revis, Mandeep R Mehra\",\"doi\":\"10.1016/j.jchf.2024.09.019\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Prior analyses have suggested that a smaller left ventricular end-diastolic diameter (LVEDD) is associated with reduced survival following HeartMate 3 left ventricular assist device implantation.</p><p><strong>Objectives: </strong>In this trial-based comprehensive analysis, the authors sought to examine clinical characteristics and association with the outcome of this specific relationship.</p><p><strong>Methods: </strong>The authors analyzed the presence of LVEDD <55 mm among 1,921 analyzable HeartMate 3 patients within the MOMENTUM 3 (Multicenter Study of MagLev Technology in Patients Undergoing Mechanical Circulatory Support Therapy With HeartMate 3) trial portfolio, on endpoints of overall survival and adverse events at 2 years. Adverse events included hemocompatibility-related (stroke, bleeding, and pump thrombosis) and non-hemocompatibility-related (right heart failure, infection) outcomes.</p><p><strong>Results: </strong>Those with a smaller LVEDD (<55 mm) (n = 108) were older (age 63 ± 11 years vs 60 ± 12 years; P = 0.005), were more often female (31% vs 20%; P = 0.096), and had more ischemic cardiomyopathy (60.2% vs 42.6%; P = 0.0004) compared with the LVEDD ≥55 mm group (n = 1,813). Death during implant hospitalization was higher (14.8 vs 5.7%; P = 0.0007) and survival at 2 years was lower (63.3% vs 81.8%; HR: 1.97 [95% CI: 1.39-2.79]; P = 0.0002) in the LVEDD <55 mm group. The LVEDD <55 mm group experienced more deaths due to hemocompatibility-related adverse events (2.8% vs 0.6%; HR: 4.61 [95% CI: 1.29-16.45]; P = 0.018) and right heart failure, both early (0-30 days; 7.4% vs 2.0%; HR: 3.70 [95% CI: 1.73-7.91]; P = 0.001) and late (>30 days; 12.0 vs 4.8%; HR: 2.58 [95% CI: 1.37-4.84]; P = 0.003). Low-flow alarms rehospitalizations were higher in the LVEDD <55 mm cohort (17.4 vs 8.3%; HR: 2.39 [95% CI: 1.59-3.59]; P < 0.001).</p><p><strong>Conclusions: </strong>Although infrequent in occurrence, smaller LVEDD (<55 mm) is associated with increased risk for early and late mortality, a consequence of hemocompatibility-related and right heart failure-related deaths. Rehospitalizations due to low-flow alarms are also more frequent. (MOMENTUM 3 IDE Clinical Study Protocol [HM3™]; NCT02224755; MOMENTUM 3 Continued Access Protocol [MOMENTUM 3 CAP]; NCT02892955).</p>\",\"PeriodicalId\":14687,\"journal\":{\"name\":\"JACC. Heart failure\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":10.3000,\"publicationDate\":\"2024-12-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"JACC. Heart failure\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1016/j.jchf.2024.09.019\",\"RegionNum\":1,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"JACC. Heart failure","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.jchf.2024.09.019","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

摘要

背景:先前的分析表明,心脏伴侣3型左室辅助装置植入后,较小的左室舒张末期直径(LVEDD)与生存率降低有关。目的:在这项基于试验的综合分析中,作者试图检查临床特征及其与这种特定关系的结果的关联。方法:作者分析了LVEDD的存在结果:LVEDD较小的患者(30天;12.0 vs 4.8%;Hr: 2.58 [95% ci: 1.37-4.84];P = 0.003)。结论:虽然低流量警报在LVEDD中的发生率较高,但较小的LVEDD (
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Left Ventricular Dimensions and Clinical Outcomes With a Fully Magnetically Levitated Left Ventricular Assist Device.

Background: Prior analyses have suggested that a smaller left ventricular end-diastolic diameter (LVEDD) is associated with reduced survival following HeartMate 3 left ventricular assist device implantation.

Objectives: In this trial-based comprehensive analysis, the authors sought to examine clinical characteristics and association with the outcome of this specific relationship.

Methods: The authors analyzed the presence of LVEDD <55 mm among 1,921 analyzable HeartMate 3 patients within the MOMENTUM 3 (Multicenter Study of MagLev Technology in Patients Undergoing Mechanical Circulatory Support Therapy With HeartMate 3) trial portfolio, on endpoints of overall survival and adverse events at 2 years. Adverse events included hemocompatibility-related (stroke, bleeding, and pump thrombosis) and non-hemocompatibility-related (right heart failure, infection) outcomes.

Results: Those with a smaller LVEDD (<55 mm) (n = 108) were older (age 63 ± 11 years vs 60 ± 12 years; P = 0.005), were more often female (31% vs 20%; P = 0.096), and had more ischemic cardiomyopathy (60.2% vs 42.6%; P = 0.0004) compared with the LVEDD ≥55 mm group (n = 1,813). Death during implant hospitalization was higher (14.8 vs 5.7%; P = 0.0007) and survival at 2 years was lower (63.3% vs 81.8%; HR: 1.97 [95% CI: 1.39-2.79]; P = 0.0002) in the LVEDD <55 mm group. The LVEDD <55 mm group experienced more deaths due to hemocompatibility-related adverse events (2.8% vs 0.6%; HR: 4.61 [95% CI: 1.29-16.45]; P = 0.018) and right heart failure, both early (0-30 days; 7.4% vs 2.0%; HR: 3.70 [95% CI: 1.73-7.91]; P = 0.001) and late (>30 days; 12.0 vs 4.8%; HR: 2.58 [95% CI: 1.37-4.84]; P = 0.003). Low-flow alarms rehospitalizations were higher in the LVEDD <55 mm cohort (17.4 vs 8.3%; HR: 2.39 [95% CI: 1.59-3.59]; P < 0.001).

Conclusions: Although infrequent in occurrence, smaller LVEDD (<55 mm) is associated with increased risk for early and late mortality, a consequence of hemocompatibility-related and right heart failure-related deaths. Rehospitalizations due to low-flow alarms are also more frequent. (MOMENTUM 3 IDE Clinical Study Protocol [HM3™]; NCT02224755; MOMENTUM 3 Continued Access Protocol [MOMENTUM 3 CAP]; NCT02892955).

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
JACC. Heart failure
JACC. Heart failure CARDIAC & CARDIOVASCULAR SYSTEMS-
CiteScore
21.20
自引率
2.30%
发文量
164
期刊介绍: JACC: Heart Failure publishes crucial findings on the pathophysiology, diagnosis, treatment, and care of heart failure patients. The goal is to enhance understanding through timely scientific communication on disease, clinical trials, outcomes, and therapeutic advances. The Journal fosters interdisciplinary connections with neuroscience, pulmonary medicine, nephrology, electrophysiology, and surgery related to heart failure. It also covers articles on pharmacogenetics, biomarkers, and metabolomics.
期刊最新文献
Elevated Neutrophil-to-Lymphocyte Ratio Predicts Prognosis in Acute Myocarditis. Antiobesity Medications in Patients With Heart Failure: A Clinical Protocol and Preliminary Single-Center Experience. Effects of Acute Phase Intensive Exercise Training in Patients With Acute Decompensated Heart Failure. 24-Month Outcomes of Endovascular Baroreflex Amplification With the MobiusHD Device in Heart Failure With Reduced Ejection Fraction. Adverse Pregnancy Outcomes and Long-Term Risk of Heart Failure in Women: National Cohort and Co-Sibling Study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1